Jieting Wang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jieting Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Nanshu Lu
Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, TX, USA
2 shared publications Pulin Wang
Stretch Med Inc
2 shared publications- Sarnab Bhattacharya
Chandra Family Department of Electrical and Computer Engineering
2 shared publications - Alec Alden
Department of Biomedical Engineering The University of Texas at Austin Austin TX 78712 USA
1 shared publication Alex Johnson
Chandra Family Department of Electrical and Computer Engineering
1 shared publication- Animesh Tandon
Department of Heart, Vascular, and Thoracic, Division of Cardiology and Cardiovascular Medicine, Children’s Institute, Cleveland Clinic Children’s, Cleveland, USA
1 shared publication
Latest Publications
- Open Access
- 14 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (29)
Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.
- 14 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (29)
Open AccessWireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.
- Open Access
- 18 April 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals
Cardiovascular diseases are the leading cause of death globally. Noninvasive, accurate, and continuous cardiovascular monitoring can enable the preemptive detection of heart diseases and timely intervention to prevent serious cardiac complications. However, unobtrusive, ambulatory, and comprehensive cardiac monitoring is still a challenge as conventional electronics are rigid, heavy, or consume too much power for long‐term measurement. This work presents a thin (200 µm), stretchable (20%), lightweight (2.5 g), wireless, and low‐power (<3 mW) cardiac monitoring device that conforms to the human chest like a temporary tattoo sticker, correspondingly known as an e‐tattoo. This chest e‐tattoo features dual‐mode electro‐mechanical sensing—bio‐electric cardiac signals via electrocardiography and mechanical cardiac rhythm via seismocardiography. A unique peripheral synchronization strategy between the two sensors enables the measurement of systolic time intervals like the pre‐ejection period and the left ventricular ejection time with high accuracy (error = −0.44 ± 8.74 ms) while consuming very low power. The e‐tattoo is validated against clinically approved gold‐standard instruments on five human subjects. The good wearability and low power consumption of this e‐tattoo permit 24‐h continuous ambulatory monitoring.
- 18 April 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
Open AccessA Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals
Cardiovascular diseases are the leading cause of death globally. Noninvasive, accurate, and continuous cardiovascular monitoring can enable the preemptive detection of heart diseases and timely intervention to prevent serious cardiac complications. However, unobtrusive, ambulatory, and comprehensive cardiac monitoring is still a challenge as conventional electronics are rigid, heavy, or consume too much power for long‐term measurement. This work presents a thin (200 µm), stretchable (20%), lightweight (2.5 g), wireless, and low‐power (<3 mW) cardiac monitoring device that conforms to the human chest like a temporary tattoo sticker, correspondingly known as an e‐tattoo. This chest e‐tattoo features dual‐mode electro‐mechanical sensing—bio‐electric cardiac signals via electrocardiography and mechanical cardiac rhythm via seismocardiography. A unique peripheral synchronization strategy between the two sensors enables the measurement of systolic time intervals like the pre‐ejection period and the left ventricular ejection time with high accuracy (error = −0.44 ± 8.74 ms) while consuming very low power. The e‐tattoo is validated against clinically approved gold‐standard instruments on five human subjects. The good wearability and low power consumption of this e‐tattoo permit 24‐h continuous ambulatory monitoring.