Gang Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gang Hu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Gang Wei
Chongqing University of Science and Technology
2 shared publications - Qiming Luo
Chongqing University of Science and Technology
2 shared publications - Zhengqin Cao
Chongqing University of Science and Technology
2 shared publications - Changli Zhou
Chongqing University of Science and Technology
1 shared publication - Jia Wang
College of Medical Informatics, Chongqing Medical University, Chongqing 400016, China
1 shared publication - Ke Wu
State Grid Chongqing Electric Power Company
1 shared publication
Latest Publications
- Open Access
- 19 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (18) , 3716
Development of a Load Monitoring Sensor for the Wire Tightener
The wire tightener is a critical tool in the construction and maintenance of power lines. Failure to detect tension overload in a timely manner may lead to plastic deformation or even breakage of the tool, potentially causing serious safety accidents. To address this issue, a force monitoring sensor was developed to track the real-time load on wire tighteners. In terms of hardware design, a foil strain gauge was integrated with an ultra-low-power mixed-signal microcontroller based on the mechanical characteristics of the wire tightener, enabling accurate acquisition and processing of load data. Low-power LoRa technology was employed for wireless data transmission, and an adaptive sleep–wake strategy was implemented to optimize power efficiency during data collection. The sensor’s material, geometry, and structure were tailored to the tool’s composition and working environment. Experimental results showed that the average relative error between the sensor readings and the reference values was less than 0.5%. The sensor has been successfully deployed in practical engineering applications, consuming approximately 4500 mWh over an 8 h continuous monitoring period.
- 19 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (18) , 3716
Open AccessDevelopment of a Load Monitoring Sensor for the Wire Tightener
The wire tightener is a critical tool in the construction and maintenance of power lines. Failure to detect tension overload in a timely manner may lead to plastic deformation or even breakage of the tool, potentially causing serious safety accidents. To address this issue, a force monitoring sensor was developed to track the real-time load on wire tighteners. In terms of hardware design, a foil strain gauge was integrated with an ultra-low-power mixed-signal microcontroller based on the mechanical characteristics of the wire tightener, enabling accurate acquisition and processing of load data. Low-power LoRa technology was employed for wireless data transmission, and an adaptive sleep–wake strategy was implemented to optimize power efficiency during data collection. The sensor’s material, geometry, and structure were tailored to the tool’s composition and working environment. Experimental results showed that the average relative error between the sensor readings and the reference values was less than 0.5%. The sensor has been successfully deployed in practical engineering applications, consuming approximately 4500 mWh over an 8 h continuous monitoring period.
- 20 December 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (10)
Development of a novel PPTA/cellulose composite insulation paper with low dielectric constant and improved mechanical properties by BTCA crosslinking
This study investigates the effect of 1,2,3,4‐butane tetracarboxylic acid (BTCA) crosslinking treatment on the electrical properties of poly‐p‐phenylene terephthalate (PPTA)/cellulose insulation paper to prepare a novel composite insulation paper with low dielectric constant and good electrical performance. Three‐layer PPTA/cellulose composite paper crosslinked by BTCA under various conditions, composite paper without crosslinking, directly mixed composite paper, and conventional Kraft paper are prepared. The morphology and surface chemical composition of the paper samples are characterized. Dielectric, mechanical, and thermal properties are investigated. Results show that the BTCA concentration of 0.2 mol L−1 with a 180°C curing temperature is the relatively superior crosslinking condition to prepare a novel composite with low dielectric constant and good comprehensive performance. The dielectric constant and loss of the novel composite paper decrease to 3.21 and 0.392 at 50 Hz. The tensile strength of the BTCA crosslinked three‐layer PPTA/cellulose composite paper (thickness: 130 μm) has reached 10.01 kN m−1, increased by 41.6% than the directly mixed composite paper. The novel BTCA crosslinked composite paper also shows improved thermal stability. The BTCA crosslinking proves to be a promising method to improve the dielectric properties and electrical performance of the PPTA/cellulose composite paper.
- 20 December 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (10)
Development of a novel PPTA/cellulose composite insulation paper with low dielectric constant and improved mechanical properties by BTCA crosslinking
This study investigates the effect of 1,2,3,4‐butane tetracarboxylic acid (BTCA) crosslinking treatment on the electrical properties of poly‐p‐phenylene terephthalate (PPTA)/cellulose insulation paper to prepare a novel composite insulation paper with low dielectric constant and good electrical performance. Three‐layer PPTA/cellulose composite paper crosslinked by BTCA under various conditions, composite paper without crosslinking, directly mixed composite paper, and conventional Kraft paper are prepared. The morphology and surface chemical composition of the paper samples are characterized. Dielectric, mechanical, and thermal properties are investigated. Results show that the BTCA concentration of 0.2 mol L−1 with a 180°C curing temperature is the relatively superior crosslinking condition to prepare a novel composite with low dielectric constant and good comprehensive performance. The dielectric constant and loss of the novel composite paper decrease to 3.21 and 0.392 at 50 Hz. The tensile strength of the BTCA crosslinked three‐layer PPTA/cellulose composite paper (thickness: 130 μm) has reached 10.01 kN m−1, increased by 41.6% than the directly mixed composite paper. The novel BTCA crosslinked composite paper also shows improved thermal stability. The BTCA crosslinking proves to be a promising method to improve the dielectric properties and electrical performance of the PPTA/cellulose composite paper.
- 25 August 2023
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 29 (3) , 391-396
Theoretical Study of Platinum Doped Anatase (101) Surface on Detecting Decomposition Production of Polyvinyl Chloride
The gas sensitivity of platinum doped TiO2 (101) to two kinds on polyvinyl chloride decomposition production, CO and HCl, were explored based on density functional theory. The binding energy, adsorption distance, charge transfer, and density of states distribution were simulated and discussed. The results suggest that the O oriented mode is probably the best mode for the CO gas molecules adsorption on the Pt-TiO2 and H oriented mode for the HCl adsorption system. HCl and CO molecules obtain electrons from Pt doped TiO2 surface. At room temperature, the recovery time of CO and HCl is 1.9743 × 10-10, 1.2094 × 10-10 respectively. HCl is easier to dissociate from Pt doped TiO2 surface with a little lower energy barrier compared to CO. This work provides theoretical adsorption information of Pt-TiO2 as gas sensor material for HCl and CO detection in the application of online condition monitoring and defect diagnosis in the power cables.
- 25 August 2023
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 29 (3) , 391-396
Theoretical Study of Platinum Doped Anatase (101) Surface on Detecting Decomposition Production of Polyvinyl Chloride
The gas sensitivity of platinum doped TiO2 (101) to two kinds on polyvinyl chloride decomposition production, CO and HCl, were explored based on density functional theory. The binding energy, adsorption distance, charge transfer, and density of states distribution were simulated and discussed. The results suggest that the O oriented mode is probably the best mode for the CO gas molecules adsorption on the Pt-TiO2 and H oriented mode for the HCl adsorption system. HCl and CO molecules obtain electrons from Pt doped TiO2 surface. At room temperature, the recovery time of CO and HCl is 1.9743 × 10-10, 1.2094 × 10-10 respectively. HCl is easier to dissociate from Pt doped TiO2 surface with a little lower energy barrier compared to CO. This work provides theoretical adsorption information of Pt-TiO2 as gas sensor material for HCl and CO detection in the application of online condition monitoring and defect diagnosis in the power cables.
- 17 August 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (44) , 445102
Theoretical study on the interaction between acetone and BN monolayer doped with Ni for the clinical diagnosis of diabetes mellitus
Endogenous volatile organic compounds (VOCs) in human exhaled gases can reflect human health status and be used for clinical diagnosis and health monitoring. Acetone is the sign VOC gases of diabetes mellitus. In order to find a potential material for the detection of acetone in the application of the clinical diagnosis of diabetes mellitus. The adsorption properties, including adsorption energy, adsorption distance, charge transfer, density of states, electron localization function and electrons density difference, of acetone on BN monolayer doped with Ni were comprehensively investigated based on density functional theory. The results show that there could be chemisorption between acetone and Ni-BN monolayer and Ni-BN monolayer is probably suitable gas sensitive material for the detection of acetone in the application of diabetes mellitus monitoring and clinical diagnosis.
- 17 August 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (44) , 445102
Theoretical study on the interaction between acetone and BN monolayer doped with Ni for the clinical diagnosis of diabetes mellitus
Endogenous volatile organic compounds (VOCs) in human exhaled gases can reflect human health status and be used for clinical diagnosis and health monitoring. Acetone is the sign VOC gases of diabetes mellitus. In order to find a potential material for the detection of acetone in the application of the clinical diagnosis of diabetes mellitus. The adsorption properties, including adsorption energy, adsorption distance, charge transfer, density of states, electron localization function and electrons density difference, of acetone on BN monolayer doped with Ni were comprehensively investigated based on density functional theory. The results show that there could be chemisorption between acetone and Ni-BN monolayer and Ni-BN monolayer is probably suitable gas sensitive material for the detection of acetone in the application of diabetes mellitus monitoring and clinical diagnosis.