Abid Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abid Ali has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Krämer
ZF Friedrichshafen AG, Schweinfurt, Germany
2 shared publications Mirza Cizmic
University of Applied Sciences,Wrzburg-Schweinfurt,D-97421 Schweinfurt,Germany
2 shared publications- Philipp Heil
Department of Electrical Engineering, Technical University of Applied Sciences Wrzburg-Schweinfurt, Schweinfurt, Germany
1 shared publication Tobias Strnad
University of Applied Sciences,Wrzburg-Schweinfurt,D-97421 Schweinfurt,Germany
1 shared publication
Latest Publications
- Open Access
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 37243-37252
Analysis, Diagnosis and Reconfiguration of a Synchronous Motor Control With Faulty DC Link Voltage Measurement
This paper discusses the effects of an incorrectly measured DC link voltage in a synchronous drive system. As the investigations show, the control algorithm can become unstable when the measured value for the DC link voltage is much smaller than the actual value. Therefore, this paper also presents two approaches for estimating the DC link voltage based on the measured currents, the motor speed and the duty cycle. If measured and estimated values of the DC link voltage deviate too much from each other, a fault diagnosis system detects this fault and enables different flags based on the fault scenario. The flags are then used to reconfigure the control algorithm, so that instead of the measured current its estimated value is used. The analysis shows the need for the reconfiguration of a faulty DC link voltage measurement and the experimental results demonstrate the effectiveness of the approach.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 37243-37252
Open AccessAnalysis, Diagnosis and Reconfiguration of a Synchronous Motor Control With Faulty DC Link Voltage Measurement
This paper discusses the effects of an incorrectly measured DC link voltage in a synchronous drive system. As the investigations show, the control algorithm can become unstable when the measured value for the DC link voltage is much smaller than the actual value. Therefore, this paper also presents two approaches for estimating the DC link voltage based on the measured currents, the motor speed and the duty cycle. If measured and estimated values of the DC link voltage deviate too much from each other, a fault diagnosis system detects this fault and enables different flags based on the fault scenario. The flags are then used to reconfigure the control algorithm, so that instead of the measured current its estimated value is used. The analysis shows the need for the reconfiguration of a faulty DC link voltage measurement and the experimental results demonstrate the effectiveness of the approach.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation of the Linear Alternative of the SMO Switching Function used for Self-Sensing High-Speed PMSM
This paper presents a reduced-order observer structure for self-sensing control of a Permanent Magnet Synchronous Machine (PMSM). The design is based on the classical Sliding Mode Observer (SMO) but it uses a linear observer gain instead of the switching function. This solves several problems faced by the SMO and can be designed in systematic way. Moreover, it delivers a more accurate estimation of the rotor angle even at high-speeds and low calculation frequencies. Design hints and a suitable rule are given. The properties of the proposed observer are compared to traditional implementation of the SMO with a signum switching function. Experimental results of a high-speed PMSM are presented to validate the approach.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation of the Linear Alternative of the SMO Switching Function used for Self-Sensing High-Speed PMSM
This paper presents a reduced-order observer structure for self-sensing control of a Permanent Magnet Synchronous Machine (PMSM). The design is based on the classical Sliding Mode Observer (SMO) but it uses a linear observer gain instead of the switching function. This solves several problems faced by the SMO and can be designed in systematic way. Moreover, it delivers a more accurate estimation of the rotor angle even at high-speeds and low calculation frequencies. Design hints and a suitable rule are given. The properties of the proposed observer are compared to traditional implementation of the SMO with a signum switching function. Experimental results of a high-speed PMSM are presented to validate the approach.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Machine-Parameter-Independent Reduction of Harmonic Errors in Self-Sensing Control of PMSM
For anisotropy-based self-sensing control of PMSM at standstill and low speeds a minimal difference between the differential d-axis and q-axis inductances is necessary. The machine geometry, saturation and inverter nonlinearities can cause rotor-position-dependent machine parameters, leading to harmonic position errors in closed loop self-sensing control. This can deteriorate the overall control performance, the stability and the acoustics of the self-sensing drive system. In this work a novel method for machine parameter free adaptive compensation of harmonic position errors is proposed and validated by experimental results.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Machine-Parameter-Independent Reduction of Harmonic Errors in Self-Sensing Control of PMSM
For anisotropy-based self-sensing control of PMSM at standstill and low speeds a minimal difference between the differential d-axis and q-axis inductances is necessary. The machine geometry, saturation and inverter nonlinearities can cause rotor-position-dependent machine parameters, leading to harmonic position errors in closed loop self-sensing control. This can deteriorate the overall control performance, the stability and the acoustics of the self-sensing drive system. In this work a novel method for machine parameter free adaptive compensation of harmonic position errors is proposed and validated by experimental results.