Sonja Wegener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sonja Wegener has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Otto A. Sauer
Department of Radiotherapy and Radiation Oncology University of Wurzburg Wurzburg Germany
12 shared publications- Gary Razinskas
Department of Radiation Oncology University Hospital Würzburg Würzburg Germany
11 shared publications Robert Schindhelm
Department of Radiation Oncology University Hospital Würzburg Würzburg Germany
8 shared publications- Jörg Tamihardja
Department of Radiation Oncology, University of Wuerzburg, 97080 Wuerzburg, Germany
4 shared publications - Stefan Weick
Department of Radiation Oncology, University Hospital Würzburg, Würzburg, Germany
4 shared publications - Anne Richter
Department of Radiation Oncology, University Hospital Wuerzburg, Josef-Schneider-Straße 11, Würzburg, 97080, Germany
3 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Development of a phantom‐based end‐to‐end QA workflow for online adaptive radiotherapy incorporating high‐resolution 2D detector measurements
Background: Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch. Therefore, an end‐to‐end QA approach, covering imaging, contouring, plan adaptation, dose calculation, and delivery, is essential to ensure accurate and reliable oART. Purpose: To develop and evaluate an end‐to‐end QA workflow for oART, incorporating high‐resolution detector‐based 2D dose verification and interchangeable phantom inserts. Methods: A novel QA workflow was implemented using the myQA® SRS phantom with a 2D CMOS detector and a 3D‐printed anthropomorphic pelvis insert. A virtually deformed planning CT was generated to simulate anatomical changes and used as input for the adaptive workflow. The process included CBCT acquisition, manual contour adaptation, plan generation, dose delivery, and comparison of measured and calculated dose distributions via Gamma Analysis. Workflow feasibility was tested through repeated measurements. Error detectability was evaluated by altering gantry/collimator angles, monitor units (MU), phantom positioning, and CBCT presets. Confidence limits, calculated following AAPM TG‐119 methodology, were used as plan‐specific thresholds for evaluating Gamma Pass Rates (GPR). Corresponding dose‐volume histogram (DVH) parameters, using D98% for the planning target volume (PTV) and V95% for organs at risk (OARs), were calculated. Results: Ethos auto‐contouring did not perform reliably on the phantom geometry, necessitating manual contouring. All workflow repetitions produced high GPR values for 3 %/2 mm, 2 %/2 mm, 3 %/1 mm, and 2 %/1 mm global criteria between measured and calculated dose. Confidence limits served as effective thresholds for identifying plan deviations. Introduced errors, including gantry angle deviations > 3° and collimator angle deviations ≥ 3°, MU variations ≥ 3 %, incorrect CBCT presets, and 3 mm setup shifts, were clearly detectable across all criteria. Smaller deviations, such as 1° angular changes or 1 % MU variation, resulting in minor dosimetric effects residing at or below 1.2 % for the PTV and 5.6 % for OARs, yielded GPR values above the Confidence limit. Conclusions: The proposed workflow is feasible, reproducible, and capable of reliably identifying plan‐specific deviations in Ethos oART. High‐resolution 2D measurements and dose comparison provided robust verification of adaptive dose calculation and delivery. While limited by manual contouring and data‐handling constraints inherent to the Ethos platform, this method represents a practical end‐to‐end QA approach for clinical oART implementation.
- 3 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessDevelopment of a phantom‐based end‐to‐end QA workflow for online adaptive radiotherapy incorporating high‐resolution 2D detector measurements
Background: Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch. Therefore, an end‐to‐end QA approach, covering imaging, contouring, plan adaptation, dose calculation, and delivery, is essential to ensure accurate and reliable oART. Purpose: To develop and evaluate an end‐to‐end QA workflow for oART, incorporating high‐resolution detector‐based 2D dose verification and interchangeable phantom inserts. Methods: A novel QA workflow was implemented using the myQA® SRS phantom with a 2D CMOS detector and a 3D‐printed anthropomorphic pelvis insert. A virtually deformed planning CT was generated to simulate anatomical changes and used as input for the adaptive workflow. The process included CBCT acquisition, manual contour adaptation, plan generation, dose delivery, and comparison of measured and calculated dose distributions via Gamma Analysis. Workflow feasibility was tested through repeated measurements. Error detectability was evaluated by altering gantry/collimator angles, monitor units (MU), phantom positioning, and CBCT presets. Confidence limits, calculated following AAPM TG‐119 methodology, were used as plan‐specific thresholds for evaluating Gamma Pass Rates (GPR). Corresponding dose‐volume histogram (DVH) parameters, using D98% for the planning target volume (PTV) and V95% for organs at risk (OARs), were calculated. Results: Ethos auto‐contouring did not perform reliably on the phantom geometry, necessitating manual contouring. All workflow repetitions produced high GPR values for 3 %/2 mm, 2 %/2 mm, 3 %/1 mm, and 2 %/1 mm global criteria between measured and calculated dose. Confidence limits served as effective thresholds for identifying plan deviations. Introduced errors, including gantry angle deviations > 3° and collimator angle deviations ≥ 3°, MU variations ≥ 3 %, incorrect CBCT presets, and 3 mm setup shifts, were clearly detectable across all criteria. Smaller deviations, such as 1° angular changes or 1 % MU variation, resulting in minor dosimetric effects residing at or below 1.2 % for the PTV and 5.6 % for OARs, yielded GPR values above the Confidence limit. Conclusions: The proposed workflow is feasible, reproducible, and capable of reliably identifying plan‐specific deviations in Ethos oART. High‐resolution 2D measurements and dose comparison provided robust verification of adaptive dose calculation and delivery. While limited by manual contouring and data‐handling constraints inherent to the Ethos platform, this method represents a practical end‐to‐end QA approach for clinical oART implementation.
- Open Access
- 24 August 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (9) , e70749
Failure modes and effects analysis for clinical implementation of online adaptive radiotherapy: A systematic review
Background: The accuracy of radiotherapy is limited by anatomical variations occurring over time scales ranging from sub‐seconds to days. Online Adaptive Radiotherapy (OART) addresses this by enabling daily plan adaptation based on real‐time imaging. While OART offers improved dose conformity, its dynamic, time‐constrained workflow introduces novel failure modes that challenge traditional quality assurance protocols. Purpose: This study aims to synthesize the existing literature on Failure Modes and Effects Analysis (FMEA) for OART to systematically catalog risks and identify mitigation strategies. Methods: A systematic literature search was conducted to identify studies applying FMEA to OART workflows. Eleven studies were included, covering MR‐guided (ViewRay MRIdian, Elekta Unity), CBCT‐guided (Varian Ethos), and MR‐enhanced C‐arm linac systems. To address heterogeneity in risk scoring methodologies (e.g., TG‐100 10‐point scales vs. 5‐point rankings), extracted failure modes were harmonized into a standardized three‐tier risk classification system (Class I: Low, Class II: Intermediate, Class III: High). Results: A total of 300 unique failure modes were identified, with 49.6 percent classified as high‐risk (Class III). Analysis revealed that the majority of high‐risk failures were concentrated in the online treatment delivery phase, specifically within human‐computer interactions and anatomical contouring steps. Conclusions: This study supports the development of tailored, robust QA frameworks that prioritize human factors and process consistency to guide safe implementation in diverse clinical settings.
- 24 August 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (9) , e70749
Open AccessFailure modes and effects analysis for clinical implementation of online adaptive radiotherapy: A systematic review
Background: The accuracy of radiotherapy is limited by anatomical variations occurring over time scales ranging from sub‐seconds to days. Online Adaptive Radiotherapy (OART) addresses this by enabling daily plan adaptation based on real‐time imaging. While OART offers improved dose conformity, its dynamic, time‐constrained workflow introduces novel failure modes that challenge traditional quality assurance protocols. Purpose: This study aims to synthesize the existing literature on Failure Modes and Effects Analysis (FMEA) for OART to systematically catalog risks and identify mitigation strategies. Methods: A systematic literature search was conducted to identify studies applying FMEA to OART workflows. Eleven studies were included, covering MR‐guided (ViewRay MRIdian, Elekta Unity), CBCT‐guided (Varian Ethos), and MR‐enhanced C‐arm linac systems. To address heterogeneity in risk scoring methodologies (e.g., TG‐100 10‐point scales vs. 5‐point rankings), extracted failure modes were harmonized into a standardized three‐tier risk classification system (Class I: Low, Class II: Intermediate, Class III: High). Results: A total of 300 unique failure modes were identified, with 49.6 percent classified as high‐risk (Class III). Analysis revealed that the majority of high‐risk failures were concentrated in the online treatment delivery phase, specifically within human‐computer interactions and anatomical contouring steps. Conclusions: This study supports the development of tailored, robust QA frameworks that prioritize human factors and process consistency to guide safe implementation in diverse clinical settings.
- Open Access
- 3 May 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 39, 100990
In-vivo dosimetry using electronic portal imaging in online-adaptive radiotherapy for rectal cancer
- 3 May 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 39, 100990
Open AccessIn-vivo dosimetry using electronic portal imaging in online-adaptive radiotherapy for rectal cancer
- Open Access
- 26 March 2026
- Published by Elsevier in Radiography
- Vol. 32 (4) , 103400
Radiation dose comparison of conventional radiography and photon-counting CT for ventriculoperitoneal shunt imaging: A phantom study
- 26 March 2026
- Published by Elsevier in Radiography
- Vol. 32 (4) , 103400
Open AccessRadiation dose comparison of conventional radiography and photon-counting CT for ventriculoperitoneal shunt imaging: A phantom study
- 22 January 2026
- Published by Springer Nature
- p. 205-225
Relative Dosimetry in Radiation Therapy
- Open Access
- 21 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (11) , e70302
Detector response and dose calculation lateral to material interfaces for 6 MV photon beam
Background: Dose calculation around inhomogeneities is challenging for many algorithms. A validation of dose distributions in these conditions is not straightforward, as detector response close to material interfaces is affected by the non‐equilibrium situation, the changing energy spectrum and the volume effect in a steep dose gradient. Purpose: Detector response lateral to an inhomogeneity of high density was studied, mimicking the situation of bone surrounded by soft tissue. Methods: Profiles obtained with different detectors (diodes, ion chamber, synthetic diamond) in water in the vicinity of an aluminum cylinder were compared. Dose deposition was also calculated with different commercial treatment planning systems and algorithms as well as using Monte Carlo simulations within and lateral to the cylinder and compared to measurements. Results: Dose deposition in the vicinity of an inserted aluminum cylinder changes and is registered by the detectors to a different degree. The ion chamber shows the largest change irradiated with a 10×10 cm 2 at 3 mm distance from the cylinder surface (2.5%), followed by the synthetic diamond (1.7%), then the unshielded (1.4%) and finally the shielded diode (1.0%). Dose calculated by different commercial dose engines differed up to 3% at that point from the detector values (Collapsed Cone). Conclusions: Dose calculation near inhomogeneities depends on the used algorithm, dose measurements in the same region differ depending on the detector type used. We recommend verification of dose calculation with second type of algorithm and measurements with at least two detector types.
- 21 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (11) , e70302
Open AccessDetector response and dose calculation lateral to material interfaces for 6 MV photon beam
Background: Dose calculation around inhomogeneities is challenging for many algorithms. A validation of dose distributions in these conditions is not straightforward, as detector response close to material interfaces is affected by the non‐equilibrium situation, the changing energy spectrum and the volume effect in a steep dose gradient. Purpose: Detector response lateral to an inhomogeneity of high density was studied, mimicking the situation of bone surrounded by soft tissue. Methods: Profiles obtained with different detectors (diodes, ion chamber, synthetic diamond) in water in the vicinity of an aluminum cylinder were compared. Dose deposition was also calculated with different commercial treatment planning systems and algorithms as well as using Monte Carlo simulations within and lateral to the cylinder and compared to measurements. Results: Dose deposition in the vicinity of an inserted aluminum cylinder changes and is registered by the detectors to a different degree. The ion chamber shows the largest change irradiated with a 10×10 cm 2 at 3 mm distance from the cylinder surface (2.5%), followed by the synthetic diamond (1.7%), then the unshielded (1.4%) and finally the shielded diode (1.0%). Dose calculated by different commercial dose engines differed up to 3% at that point from the detector values (Collapsed Cone). Conclusions: Dose calculation near inhomogeneities depends on the used algorithm, dose measurements in the same region differ depending on the detector type used. We recommend verification of dose calculation with second type of algorithm and measurements with at least two detector types.
- Open Access
- 28 February 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (5) , 596
Patient Shielding in Ultra-High-Resolution Cone-Beam CT of the Upper Extremity with a Twin Robotic X-Ray System
Background/Objectives: Gantry-free cone-beam CT (CBCT) allows for ultra-high-resolution (UHR) upper extremity imaging in a comfortable tableside position. The aim of this study was to assess the organ-specific radiation burden and the effect of dedicated lead shielding in the UHR-CBCT of the wrist and elbow. Methods: A modified Alderson-Rando phantom was scanned with the tableside UHR-CBCT mode of a twin robotic X-ray system employing identical scan parameters for wrist and elbow imaging. An ion chamber was used in conjunction with an electrometer to obtain representative organ dose measurements for the eye lens, thyroid gland, breast tissue, and abdomen. All measurements were performed with and without lead shielding. Results: Irrespective of the examined upper extremity joint, the highest absorbed dose among the assessed organs was determined for the eye lens (wrist imaging: 0.10 ± 0.01 mGy, elbow imaging: 0.12 ± 0.01 mGy). The most effective organ dose reduction by means of shielding in wrist CBCT was achieved for the thyroid gland (−17%). In elbow CBCT, the abdomen (−48%) and the ipsilateral breast (−39%) benefited particularly from shield protection. Conclusions: Although shielding was more effective in elbow than wrist scans, the overall impact in terms of absolute dose reduction was marginal.
- 28 February 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (5) , 596
Open AccessPatient Shielding in Ultra-High-Resolution Cone-Beam CT of the Upper Extremity with a Twin Robotic X-Ray System
Background/Objectives: Gantry-free cone-beam CT (CBCT) allows for ultra-high-resolution (UHR) upper extremity imaging in a comfortable tableside position. The aim of this study was to assess the organ-specific radiation burden and the effect of dedicated lead shielding in the UHR-CBCT of the wrist and elbow. Methods: A modified Alderson-Rando phantom was scanned with the tableside UHR-CBCT mode of a twin robotic X-ray system employing identical scan parameters for wrist and elbow imaging. An ion chamber was used in conjunction with an electrometer to obtain representative organ dose measurements for the eye lens, thyroid gland, breast tissue, and abdomen. All measurements were performed with and without lead shielding. Results: Irrespective of the examined upper extremity joint, the highest absorbed dose among the assessed organs was determined for the eye lens (wrist imaging: 0.10 ± 0.01 mGy, elbow imaging: 0.12 ± 0.01 mGy). The most effective organ dose reduction by means of shielding in wrist CBCT was achieved for the thyroid gland (−17%). In elbow CBCT, the abdomen (−48%) and the ipsilateral breast (−39%) benefited particularly from shield protection. Conclusions: Although shielding was more effective in elbow than wrist scans, the overall impact in terms of absolute dose reduction was marginal.
- Open Access
- 12 June 2024
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 34 (3) , 397-407
Re-evaluation of the prospective risk analysis for artificial-intelligence driven cone beam computed tomography-based online adaptive radiotherapy after one year of clinical experience
- 12 June 2024
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 34 (3) , 397-407
Open AccessRe-evaluation of the prospective risk analysis for artificial-intelligence driven cone beam computed tomography-based online adaptive radiotherapy after one year of clinical experience
- Open Access
- 22 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (7) , e14311
Feasibility of Ethos adaptive treatments of lung tumors and associated quality assurance
Motivation: Online adaptive radiotherapy with Ethos is based on the anatomy determined from daily cone beam computed tomography (CBCT) images. Dose optimization and computation are performed on the density map of a synthetic CT (sCT), a deformable registration of the initial planning CT (pCT) onto the current CBCT. Large density changes as present in the lung region are challenging the system.Methods: Treatment plans for Ethos were created and delivered for 1, 2, and 3 cm diameter lung lesions in an anthropomorphic phantom, combining different insets in the pCT and during adaptive and non‐adaptive treatment sessions. Primary and secondary dose calculations as well as back‐projected dose from portal images were evaluated.Results: Density changes due to changed insets were not considered in the sCTs. This resulted in errors in the dose; for example, ‐15.9% of the mean dose for a plan when changing from a 3 cm inset in the pCT to 1 cm at the time of treatment. Secondary dose calculation is based on the sCT and could therefore not reveal these dose errors. However, dose calculation on the CBCT, either as a recalculation in the treatment planning system or as pre‐treatment quality assurance (QA) before the treatment, indicated the differences. EPID in‐vivo QA also reported discrepancies between calculated and delivered dose distributions.Conclusions: An incorrect density distribution in the sCT has an impact on the dose calculation accuracy in the adaptive treatment workflow with the Ethos system. Additional quality checks of the sCT can detect such errors.
- 22 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (7) , e14311
Open AccessFeasibility of Ethos adaptive treatments of lung tumors and associated quality assurance
Motivation: Online adaptive radiotherapy with Ethos is based on the anatomy determined from daily cone beam computed tomography (CBCT) images. Dose optimization and computation are performed on the density map of a synthetic CT (sCT), a deformable registration of the initial planning CT (pCT) onto the current CBCT. Large density changes as present in the lung region are challenging the system.Methods: Treatment plans for Ethos were created and delivered for 1, 2, and 3 cm diameter lung lesions in an anthropomorphic phantom, combining different insets in the pCT and during adaptive and non‐adaptive treatment sessions. Primary and secondary dose calculations as well as back‐projected dose from portal images were evaluated.Results: Density changes due to changed insets were not considered in the sCTs. This resulted in errors in the dose; for example, ‐15.9% of the mean dose for a plan when changing from a 3 cm inset in the pCT to 1 cm at the time of treatment. Secondary dose calculation is based on the sCT and could therefore not reveal these dose errors. However, dose calculation on the CBCT, either as a recalculation in the treatment planning system or as pre‐treatment quality assurance (QA) before the treatment, indicated the differences. EPID in‐vivo QA also reported discrepancies between calculated and delivered dose distributions.Conclusions: An incorrect density distribution in the sCT has an impact on the dose calculation accuracy in the adaptive treatment workflow with the Ethos system. Additional quality checks of the sCT can detect such errors.