  • In vivo dynamic optical coherence tomography of human skin with hardware- and software-based motion correction

    by Yu Guo, Rion Morishita, Ibrahim Abd El-Sadek, Kohei Yamazaki, Shingo Sakai, Pradipta Mukherjee, Yiheng Lim, Cunyou Bao, Haotian Li, Keiichi Sugata, et al.

    In vivo application of dynamic optical coherence tomography (DOCT) is hindered by bulk motion of the sample. We demonstrate DOCT imaging of in vivo human skin by adopting a sample-fixation attachment to suppress bulk motion and a subsequent software motion correction to further reduce the effect of sample motion. The performance of the motion-correction method was assessed by DOCT image observation, statistical analysis of the mean DOCT values, and subjective image grading. Both the mean DOCT value analysis and subjective grading showed statistically significant improvement of the DOCT image quality. In addition, a previously unobserved high DOCT layer was identified though image observation, which may represent the stratum basale with high keratinocyte proliferation.


  • Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals

    by Shumpei Fujimura, Ibrahim Abd El-Sadek, Rion Morishita, Shuichi Makita, Atsuko Furukawa, Pradipta Mukherjee, Yiheng Lim, Lida Zhu, Yunake Feng, Thitiya Seesan, et al.

    The wavelength and system-resolution dependencies of dynamic optical coherence tomography (DOCT) are investigated experimentally and numerically. Experimental investigations demonstrate significant wavelength dependency for the DOCT values but no marked resolution dependency. Numerical simulations were performed using diffusion, random-ballistic motion, and mono-directional flow-based motion models. Diffusion and random-ballistic motion-based simulations show significant wavelength dependency. Additionally, these simulations revealed a small but certain resolution dependency. Mono-directional flow simulations did not show wavelength dependency but did demonstrate resolution dependency. The DOCT value is sensitive to both tissue dynamics and the OCT system specification. These effects should be considered when interpreting DOCT images.


  • Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise

    by Yuanke Feng, Shumpei Fujimura, Yiheng Lim, Thitiya Seesan, Rion Morishita, Ibrahim Abd El-Sadek, Pradipta Mukherjee, Shuichi Makita, Yoshiaki Yasuno

    Dynamic optical coherence tomography (DOCT) enables label-free functional imaging by capturing temporal OCT signal variations caused by intracellular and intratissue motions. However, the relationship between DOCT signals and the sample motion behind them remains unclear. This paper presents a comprehensive DOCT simulation framework that incorporates mathematical models of intracellular/intratissue motions, two OCT signal generator types that generate OCT signal time sequences from the moving scatterer models, and representative DOCT algorithms. The theory and algorithms of the framework are described in detail, and the utility of this framework is demonstrated through numerical studies. This framework is available as open source and will enhance the understanding and utility of DOCT.


  • The comprehensive simulation framework of dynamic optical coherence tomography for the investigation on intratissue dynamics (Conference Presentation)

    by Yuanke Feng, Fujimura Shumpei, Yiheng Lim, Thitiya Seesan, Rion Morishita, Ibrahim Abd El-Sadek, Pradipta Mukherjee, Yoshiaki Yasuno

    Dynamic optical coherence tomography (DOCT) is a label-free imaging method that captures temporal OCT signal fluctuation that attributes to intracellular and intratissue motilities. This study presents a DOCT signal simulator using mathematical models for seven motility categories, generating dynamic OCT speckle patterns and incorporating physically accurate noise. As the analysis examples, we computed three DOCT contrasts: logarithmic intensity variance (LIV), OCT correlation decay speed (OCDS), and amplitude power spectrum (APS). Results indicate LIV increases and APS broadens with scatterer’s speed, while OCDS shows a peak at a specific speed. The DOCT signals maintain reliability at signal-to-noise ratios above 30 dB.

  • Imaging local optic axis of multilayered tissue using Jones-matrix optical coherence tomography

    by Yiheng Lim, Pradipta Mukherjee, Shuichi Makita, Yoshiaki Yasuno

    Polarization-sensitive Optical Coherence Tomography (PS-OCT) is a label-free and volumetric modality for birefringence and optic axis imaging, capable of visualizing the organization and orientation of fiber tissues. Measuring the optic axis of fiber tissues has been challenging for PS-OCT due to the polarization effects accumulated from overlying birefringent layers. This paper proposes an efficient PS-OCT algorithm for reconstructing the local optic axis of multi-layered birefringent tissues by exploiting the vector and matrix products of Stokes vectors. When measuring multiple layers of retarders using PS-OCT, the measured Stokes vector rotates around the optic axis of each layer at an angle determined by its phase retardation on the Poincaré sphere. This causes the measured optic axis to be accumulatively rotated by the overlaying retarders. Our algorithm effectively geometrically reverses the accumulated rotations of the measured Stokes vector caused by the overlaying retarders, enabling the reconstruction of the optic axis local to each layer. The reconstruction algorithm was applied to datasets of a retarder phantom and an in vivo fingernail bed measured by Jones-matrix based PS-OCT. The phantom consisted of three 3D printer filaments stacked as a triangle. The inter-filament angles were computed from the structural OCT image for reference (denoted as reference angles). The optic axis orientation of each filament was computed, at first, at the regions not covered by other filaments. The maximum difference of the measured orientation to the reference angles was as small as 4.6°. The local axis orientations were then computed at two regions covered by two different filaments. The maximum difference of the axis orientations at the covered and non-covered regions of the same filament was as reasonably small as 14.8°. The nail and the skin at the nailbed region exhibited different optic axes.

  • Multiple scattering suppression for in vivo optical coherence tomography measurement using the B-scan-wise multi-focus averaging method

    by Yiqiang Zhu, Lida Zhu, Yiheng Lim, Shuichi Makita, Yu Guo, Yoshiaki Yasuno

    We demonstrate a method that reduces the noise caused by multi-scattering (MS) photons in an in vivo optical coherence tomography image. This method combines a specially designed image acquisition (i.e., optical coherence tomography scan) scheme and subsequent complex signal processing. For the acquisition, multiple cross-sectional images (frames) are sequentially acquired while the depth position of the focus is altered for each frame by an electrically tunable lens. In the signal processing, the frames are numerically defocus-corrected, and complex averaged. Because of the inconsistency in the MS-photon trajectories among the different electrically tunable lens-induced defocus, this averaging reduces the MS signal. Unlike the previously demonstrated volume-wise multi-focus averaging method, our approach requires the sample to remain stable for only a brief period, approximately 70 ms, thus making it compatible with in vivo imaging. This method was validated using a scattering phantom and in vivo unanesthetized small fish samples, and was found to reduce MS noise even for unanesthetized in vivo measurement.


  • Optical-coherence-tomography-based deep-learning scatterer-density estimator using physically accurate noise model

    by Thitiya Seesan, Pradipta Mukherjee, Ibrahim Abd El-Sadek, Yiheng Lim, Lida Zhu, Shuichi Makita, Yoshiaki Yasuno

    We demonstrate a deep-learning-based scatterer density estimator (SDE) that processes local speckle patterns of optical coherence tomography (OCT) images and estimates the scatterer density behind each speckle pattern. The SDE is trained using large quantities of numerically simulated OCT images and their associated scatterer densities. The numerical simulation uses a noise model that incorporates the spatial properties of three types of noise, i.e., shot noise, relative-intensity noise, and non-optical noise. The SDE’s performance was evaluated numerically and experimentally using two types of scattering phantom and in vitro tumor spheroids. The results confirmed that the SDE estimates scatterer densities accurately. The estimation accuracy improved significantly when compared with our previous deep-learning-based SDE, which was trained using numerical speckle patterns generated from a noise model that did not account for the spatial properties of noise.


  • Polarization-artifact reduction and accuracy improvement of Jones-matrix polarization-sensitive optical coherence tomography by multi-focus-averaging based multiple scattering reduction

    by Lida Zhu, Shuichi Makita, Junya Tamaoki, Yiqiang Zhu, Pradipta Mukherjee, Yiheng Lim, Makoto Kobayashi, Yoshiaki Yasuno

    Polarization-sensitive optical coherence tomography (PS-OCT) is a promising biomedical imaging tool for the differentiation of various tissue properties. However, the presence of multiple-scattering (MS) signals can degrade the quantitative polarization measurement accuracy. We demonstrate a method to reduce MS signals and increase the measurement accuracy of Jones matrix PS-OCT. This method suppresses MS signals by averaging multiple Jones matrix volumes measured using different focal positions. The MS signals are decorrelated among the volumes by focus position modulation and are thus reduced by averaging. However, the single scattering signals are kept consistent among the focus-modulated volumes by computational refocusing. We validated the proposed method using a scattering phantom and a postmortem medaka fish. The results showed reduced artifacts in birefringence and degree-of-polarization uniformity measurements, particularly in deeper regions in the samples. This method offers a practical solution to mitigate MS-induced artifacts in PS-OCT imaging and improves quantitative polarization measurement accuracy.


  • Open Access

    Multi-focus averaging for multiple scattering suppression in optical coherence tomography

    by Lida Zhu, Shuichi Makita, Junya Tamaoki, Antonia Lichtenegger, Yiheng Lim, Yiqiang Zhu, Makoto Kobayashi, Yoshiaki Yasuno

    Multiple scattering is one of the main factors that limits the penetration depth of optical coherence tomography (OCT) in scattering samples. We propose a method termed multi-focus averaging (MFA) to suppress the multiple-scattering signals and improve the image contrast of OCT in deep regions. The MFA method captures multiple OCT volumes with various focal positions and averages them in complex form after correcting the varying defocus through computational refocusing. Because the multiple-scattering takes different trajectories among the different focal position configurations, this averaging suppresses the multiple-scattering signal. Meanwhile, the single-scattering takes a consistent trajectory regardless of the focal position configuration and is not suppressed. Hence, the MFA method improves the ratio between the single-scattering signal and multiple-scattering signal, resulting in an enhancement in the image contrast. A scattering phantom and a postmortem zebrafish were measured to validate the proposed method. The results showed that the contrast of intensity images of both the phantom and zebrafish were improved using the MFA method, such that they were better than the contrast provided by the standard single focus averaging method. The MFA method provides a cost-effective solution for contrast enhancement through multiple-scattering reduction in tissue imaging using OCT systems.


  • Open Access

    Label-free intratissue activity imaging of alveolar organoids with dynamic optical coherence tomography

    by Rion Morishita, Toshio Suzuki, Pradipta Mukherjee, Ibrahim Abd El-Sadek, Yiheng Lim, Antonia Lichtenegger, Shuichi Makita, Kiriko Tomita, Yuki Yamamoto, Tetsuharu Nagamoto, et al.

    An organoid is a three-dimensional (3D) in vitro cell culture emulating human organs. We applied 3D dynamic optical coherence tomography (DOCT) to visualize the intratissue and intracellular activities of human induced pluripotent stem cells (hiPSCs)-derived alveolar organoids in normal and fibrosis models. 3D DOCT data were acquired with an 840-nm spectral domain optical coherence tomography with axial and lateral resolutions of 3.8 µm (in tissue) and 4.9 µm, respectively. The DOCT images were obtained by the logarithmic-intensity-variance (LIV) algorithm, which is sensitive to the signal fluctuation magnitude. The LIV images revealed cystic structures surrounded by high-LIV borders and mesh-like structures with low LIV. The former may be alveoli with a highly dynamics epithelium, while the latter may be fibroblasts. The LIV images also demonstrated the abnormal repair of the alveolar epithelium.