FSFredy Solís-Dante

Fredy Solís-Dante

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fredy Solís-Dante has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Factors Associated with the Level of Knowledge about Biosafety against COVID-19 in Peruvian Dental Students: A Cross-Sectional Study under a Multivariable Regression Model

    by John Santome-Pariona, Gissela Briceño-Vergel, Nancy Córdova-Limaylla, Marysela Ladera-Castañeda, José Huamani-Echaccaya, Rita Tolmos-Valdivia, Juan Huamani-Cantoral, Fredy Solís-Dante, Luis Cervantes-Ganoza, César Cayo-Rojas

    Aim: Biosafety is a set of preventive measures aimed at controlling risk factors arising from biological, physical, and/or chemical agents. This topic is particularly important in the dental field since saliva is the main biological agent of the transmission of coronavirus. The present study aimed to determine the factors associated with the level of knowledge about biosafety against COVID-19 in Peruvian dentistry students. Materials and Methods: The present observational, cross-sectional, and analytical study evaluated 312 Peruvian dentistry students. A validated 20-question questionnaire was used to measure the level of knowledge. The nonparametric Mann–Whitney U and Kruskal–Wallis tests were used to compare levels of knowledge between categories of each variable. A logit model was used to evaluate associated factors such as sex, age, marital status, place of origin, academic year of study, being in the academic upper third, history of COVID-19, and living with vulnerable family members. A significance level of p < 0.05 was considered. Results: 36.2%, 31.4%, and 32.4% presented poor, fair, and good knowledge levels, respectively. Students under 25 years of age were 64% less likely to pass the biosafety against COVID-19 questionnaire than students 25 years of age and older (OR = 0.36; CI: 0.20–0.66). Students in the academic upper third were nine times more likely to pass the test than other students (OR = 9.38; CI: 4.61–19.07). Finally, third-year students were 52% less likely to pass the exam than fifth-year students (OR = 0.48; CI: 0.28–0.83). Conclusion: Only a minority of dentistry students had a good level of knowledge about biosafety against COVID-19. Younger and less educated students were more likely to fail the questionnaire. On the other hand, those students with outstanding academic performance were more likely to pass the questionnaire.


  • Open Access

    Factors associated with the perception of university professors about academic dishonesty in dental students from two peruvian universities: analysis under multivariable regression model

    by Marysela Ladera-Castañeda, Flavia León-Málaga, Mary Espinoza-Olórtegui, Miriam Nicho-Valladares, Luis Cervantes-Ganoza, Arturo Verástegui-Sandoval, Fredy Solís-Dante, Miriam Castro-Rojas, César Félix Cayo-Rojas

    Background: Academic dishonesty is an intentional behavior that transgresses ethics in the teaching-learning process. The present study aimed to evaluate the factors associated with the perception of university professors about academic dishonesty in dental students from two universities in the Peruvian capital.Methods: This cross-sectional, analytical study evaluated 181 professors from two Peruvian universities between March and July 2022. A validated 28-item questionnaire was used to measure the perceived academic dishonesty of their students. Alogitmodel was used to evaluate the influence of the variables gender, marital status, place of origin, academic degree, specialization, academic area, years of teaching experience, scientific publications, ethical training and university of origin, considering a significance level of p < 0.05.Results: According to the median, professors perceived that their students sometimes had attitudes and motivations to commit academic dishonesty. The professors whose origin was the capital city were twice as likely to perceive dishonest attitudes in dental students as those whose origin was a province (OR = 2.04; 95% CI: 1.06–3.93). University professors in pre-clinical courses were 0.37 times less likely to perceive dishonest attitudes than those teaching in the dental clinic (OR = 0.37; CI: 0.15–0.91). University professors in basic science courses and professors in preclinical courses were 0.43 times (OR = 0.43; CI: 0.19–0.96) and 0.39 times (OR = 0.39; CI: 0.15–0.98) less likely to perceive dishonest motivations in their students compared to university professors in the dental clinic. Gender, marital status, academic degree, specialty, years of teaching experience, scientific publications and ethical training were not found to be influential factors (p > 0.05).Conclusion: Although all university professors surveyed perceived dishonest attitudes and motivations in their students, university professors from the capital city perceived such attitudes more. In addition, being a preclinical university professor was a hindered factor for perceiving such dishonest attitudes and motivations. It is advisable to implement and constantly disseminate regulations that empower academic integrity as well as to manage a system for reporting misconduct and to make students aware of the impact of dishonesty in their professional training.


  • Open Access

    In Vitro Color Stability Evaluation of Three Polished and Unpolished Nanohybrid Resin Composites Immersed in a 0.12% Chlorhexidine-Based Mouthwash at Different Times

    by Reyna Allccahuaman-Avalos, Ramín Medina-Sánchez, Leonor Castro-Ramirez, Marysela Ladera-Castañeda, Luis Cervantes-Ganoza, Reynaldo Martínez-Campos, Fredy Solís-Dante, Ana Aliaga-Mariñas, Arturo Verástegui-Sandoval, César Cayo-Rojas

    The use of chlorhexidine-based mouthwashes on resin composites with rough surfaces can cause discoloration which compromises the esthetic of patients. The present study aimed to evaluate the in vitro color stability of Forma (Ultradent Products, Inc., South Jordan), Tetric N-Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z350XT (3M, ESPE, St. Paul, MN, USA) resin composites, with and without polishing, after being immersed in a 0.12% chlorhexidine (CHX)-based mouthwash at different times. The present in vitro experimental and longitudinal study used 96 nanohybrid resin composite blocks (Forma, Tetric N-Ceram and Filtek Z350XT) 8 mm in diameter and 2 mm thick, evenly distributed. Each resin composite group was divided into two subgroups (n = 16) with and without polishing and then immersed in a 0.12% CHX-based mouthwash for 7, 14, 21 and 28 days. Color measurements were performed with a calibrated digital spectrophotometer. Nonparametric tests were used to compare independent (Mann–Whitney U and Kruskal–Wallis) and related (Friedman) measures. In addition, the Bonferroni post hoc correction was used considering a significance level of p < 0.05. All polished and unpolished resin composites presented color variation < 3.3 when immersed for up to 14 days in 0.12% CHX-based mouthwash. The polished resin composite with the lowest color variation (ΔE) values over time was Forma, and the one with the highest values was Tetric N-Ceram. When comparing the color variation (ΔE) over time, it was observed that the three resin composites, with and without polishing, presented a significant change (p < 0.001), although these changes in color variation (ΔE) were evident from 14 days between each color acquisition (p < 0.05). The unpolished Forma and Filtek Z350XT resin composites showed significantly more color variation than the same polished ones at all times when immersed in a 0.12% CHX-based mouthwash for 30 s daily. In addition, every 14 days, all three resin composites with and without polishing showed a significant color change, while, every 7 days, color stability was maintained. All the resin composites showed clinically acceptable color stability when exposed for up to 14 days to the above-mentioned mouthwash.


  • Open Access

    Microleakage of Class II Bulk-Fill Resin Composite Restorations Cured with Light-Emitting Diode versus Quartz Tungsten-Halogen Light: An In Vitro Study in Human Teeth

    by Jenny López-Torres, Karen Hernández-Caba, Luis Cervantes-Ganoza, Marysela Ladera-Castañeda, Reynaldo Martínez-Campos, Fredy Solís-Dante, Gissela Briceño-Vergel, César Cayo-Rojas

    Background: Resin composites undergo a certain degree of shrinkage when light-cured with different light sources available on the market, resulting in microleakage of dental restorations. The aim of the present study was to assess microleakage of class II restorations with bulk-fill resin composites cured with LED (light-emitting diode) and QTH (quartz tungsten-halogen light) units, both in cervical and occlusal areas of cavity preparations. Materials and Methods: In the present in vitro experimental study, a total of 30 human molar teeth were used, in which 60 class II cavities were prepared (mesial and distal) and restored with Filtek bulk fill resin composite. Restorations were equally distributed in 3 groups according to type of curing light: A, QTH (Litex 680A Dentamerica®); B, LED (Bluephase N® 3rd generation); and C, LED (Valo® 3rd generation). Each group was further subdivided into subgroups 1 and 2 according to IV-A or IV-B resin composite color. Restored teeth were subjected to 20,000 thermal cycles between 5° and 55 °C, then immersed in 1M silver nitrate solution for 24 h. Subsequently, the teeth were sectioned mesiodistally to obtain samples for observation under stereomicroscope in order to determine microleakage degree. Kruskal–Wallis H and Mann–Whitney U statistical tests were applied with a significance level of 5% (p < 0.05). Results: No statistically significant differences were found in the degree of microleakage of bulk-fill resin composites light-cured with LED and QTH units for both occlusal (p > 0.05) and cervical areas (p > 0.05). Additionally, no significant differences were found when comparing microleakage between occlusal and cervical areas (p > 0.05), regardless of lamp type. In addition, significant differences in microleakage degree were found between bulk-fill resins with IV-A and IV-B shades when they were light-cured with QTH at cervical level (p = 0.023). However, there were no significant differences when comparing these bulk-fill resin composite shades at occlusal level with LED (p > 0.05) and QTH (p > 0.05) units. Conclusions: Class II restorations with bulk-fill resin composite in IV-A and IV-B shades light-cured with third generation LED lamp and QTH showed no significant differences in microleakage when compared in both occlusal and cervical areas. On the other hand, significantly more microleakage was found at the cervical level when a darker shade of resin composite was used and light-cured with the QTH unit.