Hideaki Mori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hideaki Mori has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hiromi Yonezawa
Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, Tokyo, Japan
1 shared publication - Hiromu Morikubo
Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, Tokyo, Japan
1 shared publication - Jun Miyoshi
Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, Tokyo, Japan
1 shared publication - Kazuyoshi Shimizu
Department of Anesthesiology and Resuscitology, Okayama University Hospital, Okayama, Japan
1 shared publication Keiichi Matsumoto
Department of Image-based Medicine, Institute of Biomedical Research and Innovation
1 shared publicationMasaki Yamasaki
Kyoto Prefectural University of Medicine Hospital, Anesthesiology, Kamigyo-ku, Japan
1 shared publication
Latest Publications
- Open Access
- 30 April 2023
- Published by Korean Association for the Study of Intestinal Diseases in Intestinal Research
- Vol. 21 (2) , 177-188
First aid with color atlas for the use of intestinal ultrasound for inflammatory bowel disease in daily clinical practice
Intestinal ultrasound (IUS) is a promising modality for the management of inflammatory bowel disease (IBD) and has the potential to particularly contribute in monitoring disease activity, an advantage crucial for optimizing the therapeutic strategy. While many IBD physicians appreciate and are interested in the use of IUS for IBD, currently only a limited number of facilities can employ this examination in daily clinical practice. A lack of guidance is one of the major barriers to introducing this procedure. Standardized protocols and assessment criteria are needed such that IUS for IBD can be considered a feasible, reliable examination in clinical practice, and multicenter clinical studies can be conducted for further clinical evidence of the application of IUS in IBD for best patient care. In this article, we provide an overview of how to start IUS for IBD and introduce basic procedures. Furthermore, IUS images from our practice are provided as a color atlas for understanding sonographic findings and scoring systems. We anticipate this “first aid” article will be helpful to promote IUS for IBD in daily practice.
- 30 April 2023
- Published by Korean Association for the Study of Intestinal Diseases in Intestinal Research
- Vol. 21 (2) , 177-188
Open AccessFirst aid with color atlas for the use of intestinal ultrasound for inflammatory bowel disease in daily clinical practice
Intestinal ultrasound (IUS) is a promising modality for the management of inflammatory bowel disease (IBD) and has the potential to particularly contribute in monitoring disease activity, an advantage crucial for optimizing the therapeutic strategy. While many IBD physicians appreciate and are interested in the use of IUS for IBD, currently only a limited number of facilities can employ this examination in daily clinical practice. A lack of guidance is one of the major barriers to introducing this procedure. Standardized protocols and assessment criteria are needed such that IUS for IBD can be considered a feasible, reliable examination in clinical practice, and multicenter clinical studies can be conducted for further clinical evidence of the application of IUS in IBD for best patient care. In this article, we provide an overview of how to start IUS for IBD and introduce basic procedures. Furthermore, IUS images from our practice are provided as a color atlas for understanding sonographic findings and scoring systems. We anticipate this “first aid” article will be helpful to promote IUS for IBD in daily practice.
- 10 March 2022
- Published by Springer Nature in Journal of Anesthesia
- Vol. 36 (3) , 367-373
The frequency of postoperative BNP measurement and intervention threshold of BNP concentration in pediatric cardiac intensive care unit: a prospective multicenter observational study
Purpose The purpose of this study is to investigate the current status of postoperative BNP measurement in the pediatric cardiac intensive care unit (PCICU). Methods This was a prospective multicenter observational study. Children under 15 years old who underwent pediatric cardiac surgery were included. Postoperatively, all BNP measurement was collected in PCICU. We checked whether each BNP measurement was used for the decision-making of intervention or not. We divided the BNP measurements into 4 groups: group A 0–299 pg/ml (reference), group B 300–999 pg/ml, group C 1000–1999 pg/ml, group D ≧ 2000 pg/ml. We performed logistic regression analysis to compare the intervention ratio between group A and B, C, D. We also did multiple comparison analyses to compare the intervention ratio in each group. Results Thirty-nine (15.8%) measurements were used as a criterion to intervene in all BNP measurements. There was no protocol for the measurement of BNP in all institutions. The number of BNP measurements in each group is as follows: group A 113 (45.9%), group B 81 (32.9%), group C 45 (18.3%), group D 7 (2.8%). The intervention ratio in each group was 6.2% (group A), 8.6% (group B), 44.4% (group C), and 71.4% (group D). The intervention ratio of group C and D were significantly higher than group A: (Odds ratio (95%CI): 12.1(4.8–33.9), p < 0.0001, 25.2(5.2–146.2), p < 0.0001). The result of multiple comparisons is similar to logistic regression analysis. Conclusion High BNP concentration, especially more than 1000 pg/ml, was more often intervened upon compared to that of less than 1000 pg/ml.
- 10 March 2022
- Published by Springer Nature in Journal of Anesthesia
- Vol. 36 (3) , 367-373
The frequency of postoperative BNP measurement and intervention threshold of BNP concentration in pediatric cardiac intensive care unit: a prospective multicenter observational study
Purpose The purpose of this study is to investigate the current status of postoperative BNP measurement in the pediatric cardiac intensive care unit (PCICU). Methods This was a prospective multicenter observational study. Children under 15 years old who underwent pediatric cardiac surgery were included. Postoperatively, all BNP measurement was collected in PCICU. We checked whether each BNP measurement was used for the decision-making of intervention or not. We divided the BNP measurements into 4 groups: group A 0–299 pg/ml (reference), group B 300–999 pg/ml, group C 1000–1999 pg/ml, group D ≧ 2000 pg/ml. We performed logistic regression analysis to compare the intervention ratio between group A and B, C, D. We also did multiple comparison analyses to compare the intervention ratio in each group. Results Thirty-nine (15.8%) measurements were used as a criterion to intervene in all BNP measurements. There was no protocol for the measurement of BNP in all institutions. The number of BNP measurements in each group is as follows: group A 113 (45.9%), group B 81 (32.9%), group C 45 (18.3%), group D 7 (2.8%). The intervention ratio in each group was 6.2% (group A), 8.6% (group B), 44.4% (group C), and 71.4% (group D). The intervention ratio of group C and D were significantly higher than group A: (Odds ratio (95%CI): 12.1(4.8–33.9), p < 0.0001, 25.2(5.2–146.2), p < 0.0001). The result of multiple comparisons is similar to logistic regression analysis. Conclusion High BNP concentration, especially more than 1000 pg/ml, was more often intervened upon compared to that of less than 1000 pg/ml.
- Open Access
- 1 January 2002
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 58 (12) , 1579-1585
Fundamental Evaluation of Segmented Attenuation Correction Method for Clinical FDG-PET Studies : Simulation of Pulmonary Mass Lesions in Phantom Studies
Objective: Both the segmented attenuation correction (SAC) method and post-injection transmission scanning are useful and widespread in clinical whole-body FDG-PET studies. The SAC method usually accomplishes smoothing of the transmission data. This calculation segments a μ-map into three degrees (lung, soft tissue, and bone) of attenuation coefficient. This method is used to reduce transmission scan time without deteriorating the quality of PET images. However, the SAC method has a tendency to underestimate the attenuation coefficient, resulting lower detectability for lung field mass lesions. We therefore evaluated the quantitative accuracy of the SAC method using transmission scanning and emission scanning data in a phantom study. Methods: A dedicated 3D PET scanner, the Siemens ECAT EXACT HR+, was used to scan images of two types of phantoms, a spherical phantom (Japan Radioisotope Association phantom) and a cylindrical phantom (20 cm in diameter). We evaluated differences between transmission images (μ-map) of the SAC method and measured attenuation correction (MAC)method, these two kinds of attenuation-corrected emission data (emission + SAC method, emission + MAC method), and emission data only (without attenuation correction). Results: In the μ-map, recovery coefficient (RC) values at 10 mm in diameter were 0.27 and 0.00 in the MAC and SAC methods, respectively, in the spherical hot area. For the emission data, the emission + SAC method and emission + MAC method showed almost the same RC values for all sizes of hot area diameter. The SAC method, however, resulted in 20% underestimation for all sizes of hot area diameter as compared with the MAC method. Conclusion: In pulmonary mass lesions, it is necessary to correct for the partial volume effect in quantitative PET measurement. However, from our data, the SAC method is not appropriate for partial volume effect correction.
- 1 January 2002
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 58 (12) , 1579-1585
Open AccessFundamental Evaluation of Segmented Attenuation Correction Method for Clinical FDG-PET Studies : Simulation of Pulmonary Mass Lesions in Phantom Studies
Objective: Both the segmented attenuation correction (SAC) method and post-injection transmission scanning are useful and widespread in clinical whole-body FDG-PET studies. The SAC method usually accomplishes smoothing of the transmission data. This calculation segments a μ-map into three degrees (lung, soft tissue, and bone) of attenuation coefficient. This method is used to reduce transmission scan time without deteriorating the quality of PET images. However, the SAC method has a tendency to underestimate the attenuation coefficient, resulting lower detectability for lung field mass lesions. We therefore evaluated the quantitative accuracy of the SAC method using transmission scanning and emission scanning data in a phantom study. Methods: A dedicated 3D PET scanner, the Siemens ECAT EXACT HR+, was used to scan images of two types of phantoms, a spherical phantom (Japan Radioisotope Association phantom) and a cylindrical phantom (20 cm in diameter). We evaluated differences between transmission images (μ-map) of the SAC method and measured attenuation correction (MAC)method, these two kinds of attenuation-corrected emission data (emission + SAC method, emission + MAC method), and emission data only (without attenuation correction). Results: In the μ-map, recovery coefficient (RC) values at 10 mm in diameter were 0.27 and 0.00 in the MAC and SAC methods, respectively, in the spherical hot area. For the emission data, the emission + SAC method and emission + MAC method showed almost the same RC values for all sizes of hot area diameter. The SAC method, however, resulted in 20% underestimation for all sizes of hot area diameter as compared with the MAC method. Conclusion: In pulmonary mass lesions, it is necessary to correct for the partial volume effect in quantitative PET measurement. However, from our data, the SAC method is not appropriate for partial volume effect correction.