  • The Effect of Temperature on Characteristics of Partial Discharge Induced by Metal Tip in GIS

    by Huan Chen, Haotian Wang, Xinyue Shi, Xutao Han, Andrea Cavallini, Junhao Li

    Partial discharge (PD) induced by metal tip is one of the most common types in gas insulated switchgear (GIS) equipment. However, the evolution of its characteristic under realistic in-service temperature stresses has not been sufficiently clarified. In this paper, a GIS prototype test platform was constructed to reproduce the actual gas temperature distribution inside the chamber, and a detection system including ultra-high frequency (UHF) sensor and photomultiplier tube (PMT) was integrated, to investigate the PD behavior caused by a metallic tip mounted on the central conductor, with the tip oriented either downward or upward in separate tests at different temperatures. The results indicate that, as the temperature increases, the PD inception voltage (PDIV) of the downward-oriented tip gradually decreases. In contrast, the PDIV of the upward-oriented tip remains almost unchanged. Regarding the repetition rate, for the downward orientation, only the negative PDs measured by the UHF exhibit a noticeable increase with temperature in the intermediate stage of PD development, whereas the other cases show slight variations. For the upward orientation, the UHF-based repetition rate of positive PDs decreases with increasing temperature, whereas that of negative PDs increases. In terms of amplitude, the average UHF pulse amplitude for both polarities decrease with temperature when the tip is oriented downward. In contrast, for the upward-oriented tip, the average amplitude of positive PDs measured by both UHF and PMT decreases with temperature, while the amplitude of negative PDs increases, and the negative PD amplitude–voltage characteristic exhibits a concave shape, i.e., it first decreases and then increases with voltage. These findings will provide helpful guidance for PD pattern recognition and insulation condition assessment in on-site GIS.

  • The Effect of Humidity on the Characteristics of Partial Discharge Induced by Metal Tip in GIS

    by Huan Chen, Xinyue Shi, Haotian Wang, Xutao Han, Andrea Cavallini, Junhao Li

    Metal tip discharge is one of the most common types of partial discharge (PD) in gas-insulated switchgear (GIS) equipment. Understanding how humidity influences PD under actual operating conditions is of great significance for assessing insulation status accurately. This paper describes a GIS prototype test platform with controllable gas humidity. It integrates detection systems, including ultra-high frequency (UHF), photomultiplier tube (PMT), and spectrometer, to investigate the PD characteristics induced by metal tips with curvature radii of 200 μm and 75 μm under varying humidity conditions. The results indicate that with increasing humidity, the PD inception voltage (PDIV) for the 200 μm tip initially decreases, then rapidly increases after 480 μL/L and stabilizes. For the 75 μm tip, PDIV decreases quickly and then stabilizes, but with increased dispersion. In terms of discharge repetition rate, the negative polarity rate first increases and then decreases with humidity, reaching a maximum at 480 μL/L; the positive polarity rate, on the other hand, monotonically increases with humidity and exhibits an earlier inception. In terms of discharge amplitude, both negative and positive polarity amplitudes gradually decrease with increasing humidity. Under high humidity conditions, UHF signals are prone to falling below the detection threshold, resulting in non-detection, whereas PMT can still record optical pulses. This phenomenon is more pronounced for small curvature tip. These conclusions provide a basis for on-site GIS PD online monitoring and insulation status diagnosis, and highlight the necessity of synchronous gas state detection.

  • Effect of Temperature on Characteristics of Surface Partial Discharge Induced by Metal Particles in GIS

    by Haotian Wang, Xinyue Shi, Yan Qin, Huan Chen, Xutao Han, Junhao Li

    Surface discharge along insulators is one of the primary causes of gas insulated switchgear (GIS) failures, with temperature variations caused by load fluctuations further affecting insulation performance. This study developed a GIS temperature control system based on oil circulation to simulate actual thermal conditions and investigated the inception and development characteristics of surface partial discharge (PD) under varying temperatures. Metallic defects were introduced on the insulator surface to initiate discharges, and the results showed that increasing temperature lowers the PD inception voltage, significantly increases the discharge repetition rate, and accelerates the transition between discharge modes. Elevated temperature also causes the amplitude-frequency distribution curves to shift toward higher amplitudes at the same voltage. On the one hand, the non-uniform temperature rises within GIS result in an uneven distribution of gas density, thereby weakening the insulation strength. On the other hand, elevated temperatures enhance the mechanisms of initial electron generation, charge decay, and secondary electron emission, further promoting the development of discharge processes. This study highlights the effect of temperature on GIS surface PD inception and development characteristics.


  • Surface Partial Discharge Characteristics of GIS Under AC and Superimposed Switching Impulse Voltage

    by Haotian Wang, Xutao Han, Xutao Wu, Huan Chen, Lin Niu, Yang Zhou, Junhao Li

    The attachment of metal particles on the surface of insulators is a significant source of surface discharges and operational failures in gas insulated switchgear (GIS). This study systematically investigated the characteristics of surface partial discharge (PD) under both AC voltage and AC superimposed switching impulse voltage, verifying the feasibility of monitoring PDs during switching operations to detect surface defects within GIS. The development of surface PD under AC voltage can be categorized into three stages with relatively low discharge amplitudes observed in the initial two stages. Surface PDs can only be effectively measured using ultra-high frequency (UHF) and optical devices once PD progression becomes pronounced. When switching impulses with an amplitude of 2.2 times AC voltage were superimposed at various AC phases, sustained and high-amplitude PDs were induced following the impulses, even when the AC voltage remains below the PD inception voltage. Space and surface charge introduced by PDs under switching impulse distort the electric field, thereby triggering subsequent discharges. The amplitude and duration of PDs excited by superimposed impulse voltage are adequate for UHF detection. This finding suggests the potential for timely detection of surface defects in GIS by monitoring PD conditions during switchgear operation.


  • Design and optimization for GIS UHF-Overvoltage composite sensor

    by Haotian Wang, Huan Chen, Zhaoyu Zhang, Xutao Han, Xuanrui Zhang, Junhao Li


  • Partial discharge detection, diagnosis, and location technology based on a novel transient earth voltage-ultrasonic integrated sensor used for switchgear equipment

    by Xutao Han, Haotian Wang, Yuan Sun, Huan Chen, Xuan Meng, Yang Zhou, Xuanrui Zhang, Junhao Li

    Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users. However, insulation faults often occur during the operation of MV switchgear and GIS because of pollution, humidity, heat, mechanical shock, and other factors. Partial discharge (PD) measurements are the most effective indicator to prevent insulation failure. Transient earth voltage (TEV) and ultrasonic methods are the most popular PD measurement methods for switchgear. Currently, these two methods are used widely and independently. In this study, a novel TEV-ultrasonic integrated sensor is proposed based on the independent structure of the TEV and the ultrasonic sensor. The performance parameters of the proposed sensor were tested on test platforms. PD measurement experiments were conducted in a 10 kV switchgear and 220 kV GIS to analyze the performance of the integrated sensor. The results show that the sensor can simultaneously measure the TEV and ultrasonic signals in the same location. The integrated sensor can realize effective and sensitive detection, precise location, and accurate diagnosis of PD in the MV switchgear and GIS.


  • A Novel Composite Sensor for UHF Partial Discharge and Gas State Measurement in GIS

    by Huan Chen, Haotian Wang, Zhaoyu Zhang, Ruochen Guo, Xutao Han, Xuanrui Zhang, Junhao Li

    The gas state of the insulating gas significantly impacts the development and extent of the partial discharge (PD) in gas insulated switchgear (GIS). Correlating these two factors allows for a more comprehensive diagnosis of insulation defects. At present, the ultra-high frequency (UHF) method has been widely used for PD detection in GIS. However, measurements of the insulating gas’s state in the field are primarily conducted offline or at gas valves, providing ineffective data for reference. To address this challenge, this paper introduces a novel composite sensor capable of simultaneous UHF and gas state measurements. Building upon the disc-type UHF sensor structure, the composite sensor integrates a gas state sensing unit with the microelectromechanical systems (MEMS) sensor as the core. A robust shielding shell is designed through finite element simulation to ensure the safety of the sensor, with the maximum induced voltage and electric field strength on the sensing unit measuring 0.28V and 414V/m, respectively. The average UHF measurement sensitivity of the composite sensor reaches 13.3mm. In addition, the composite sensor exhibits low errors (±0.2°C, ±3kPa and ±10μL/L), high consistency and repeatability in temperature, pressure and moisture measurement. Finally, the composite sensor has demonstrated its capability to simultaneously and safely detect PD signals and the gas state within GIS.


  • A Novel IEPE AE-Vibration-Temperature-Combined Intelligent Sensor for Defect Detection of Power Equipment

    by Zhaoyu Zhang, Haotian Wang, Huan Chen, Tianyi Shi, Yanfeng Song, Xutao Han, Junhao Li

    Insulation and mechanical defects are the main reasons of the power equipment fault, the former could generate partial discharge (PD) which can be detected by acoustic emission (AE) sensor, the other one can be evaluated by vibration and temperature variation. However, the two defects are detected and analyzed independently in traditional detection, the importance of multi-signal interaction and fusion analysis is ignored. To realize multi-signal synchronous detection and associated analysis, and improve the accuracy and efficiency of state evaluation of power equipment, a novel integrated electronics piezoelectric (IEPE) AE-vibration-temperature combined intelligent sensor is proposed and developed in this paper. Reasonable structure design and components customization enable the sensor to acquire signals simultaneously. Meanwhile, integrated transducer electronic data sheet (TEDS) and data processing circuit intelligentize the combined sensor. The primary detection parameters of the sensor are acquired in the calibration experiments. In PD, vibration and temperature joint experiment, it is verified that the combined sensor is more sensitive and multifunctional. Besides, a new fusion analysis diagram, vibration-phase resolved partial discharge (V-PRPD), is proposed to characterise the correlation between PD and vibration.