Haotian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haotian Wang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Junhao Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
15 shared publications - Xutao Han
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
11 shared publications - Huan Chen
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
8 shared publications - Xuanrui Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
7 shared publications - Zhaoyu Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
4 shared publications - Ruochen Guo
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China
3 shared publications
Latest Publications
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
The Effect of Temperature on Characteristics of Partial Discharge Induced by Metal Tip in GIS
Partial discharge (PD) induced by metal tip is one of the most common types in gas insulated switchgear (GIS) equipment. However, the evolution of its characteristic under realistic in-service temperature stresses has not been sufficiently clarified. In this paper, a GIS prototype test platform was constructed to reproduce the actual gas temperature distribution inside the chamber, and a detection system including ultra-high frequency (UHF) sensor and photomultiplier tube (PMT) was integrated, to investigate the PD behavior caused by a metallic tip mounted on the central conductor, with the tip oriented either downward or upward in separate tests at different temperatures. The results indicate that, as the temperature increases, the PD inception voltage (PDIV) of the downward-oriented tip gradually decreases. In contrast, the PDIV of the upward-oriented tip remains almost unchanged. Regarding the repetition rate, for the downward orientation, only the negative PDs measured by the UHF exhibit a noticeable increase with temperature in the intermediate stage of PD development, whereas the other cases show slight variations. For the upward orientation, the UHF-based repetition rate of positive PDs decreases with increasing temperature, whereas that of negative PDs increases. In terms of amplitude, the average UHF pulse amplitude for both polarities decrease with temperature when the tip is oriented downward. In contrast, for the upward-oriented tip, the average amplitude of positive PDs measured by both UHF and PMT decreases with temperature, while the amplitude of negative PDs increases, and the negative PD amplitude–voltage characteristic exhibits a concave shape, i.e., it first decreases and then increases with voltage. These findings will provide helpful guidance for PD pattern recognition and insulation condition assessment in on-site GIS.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
The Effect of Temperature on Characteristics of Partial Discharge Induced by Metal Tip in GIS
Partial discharge (PD) induced by metal tip is one of the most common types in gas insulated switchgear (GIS) equipment. However, the evolution of its characteristic under realistic in-service temperature stresses has not been sufficiently clarified. In this paper, a GIS prototype test platform was constructed to reproduce the actual gas temperature distribution inside the chamber, and a detection system including ultra-high frequency (UHF) sensor and photomultiplier tube (PMT) was integrated, to investigate the PD behavior caused by a metallic tip mounted on the central conductor, with the tip oriented either downward or upward in separate tests at different temperatures. The results indicate that, as the temperature increases, the PD inception voltage (PDIV) of the downward-oriented tip gradually decreases. In contrast, the PDIV of the upward-oriented tip remains almost unchanged. Regarding the repetition rate, for the downward orientation, only the negative PDs measured by the UHF exhibit a noticeable increase with temperature in the intermediate stage of PD development, whereas the other cases show slight variations. For the upward orientation, the UHF-based repetition rate of positive PDs decreases with increasing temperature, whereas that of negative PDs increases. In terms of amplitude, the average UHF pulse amplitude for both polarities decrease with temperature when the tip is oriented downward. In contrast, for the upward-oriented tip, the average amplitude of positive PDs measured by both UHF and PMT decreases with temperature, while the amplitude of negative PDs increases, and the negative PD amplitude–voltage characteristic exhibits a concave shape, i.e., it first decreases and then increases with voltage. These findings will provide helpful guidance for PD pattern recognition and insulation condition assessment in on-site GIS.
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
The Effect of Humidity on the Characteristics of Partial Discharge Induced by Metal Tip in GIS
Metal tip discharge is one of the most common types of partial discharge (PD) in gas-insulated switchgear (GIS) equipment. Understanding how humidity influences PD under actual operating conditions is of great significance for assessing insulation status accurately. This paper describes a GIS prototype test platform with controllable gas humidity. It integrates detection systems, including ultra-high frequency (UHF), photomultiplier tube (PMT), and spectrometer, to investigate the PD characteristics induced by metal tips with curvature radii of 200 μm and 75 μm under varying humidity conditions. The results indicate that with increasing humidity, the PD inception voltage (PDIV) for the 200 μm tip initially decreases, then rapidly increases after 480 μL/L and stabilizes. For the 75 μm tip, PDIV decreases quickly and then stabilizes, but with increased dispersion. In terms of discharge repetition rate, the negative polarity rate first increases and then decreases with humidity, reaching a maximum at 480 μL/L; the positive polarity rate, on the other hand, monotonically increases with humidity and exhibits an earlier inception. In terms of discharge amplitude, both negative and positive polarity amplitudes gradually decrease with increasing humidity. Under high humidity conditions, UHF signals are prone to falling below the detection threshold, resulting in non-detection, whereas PMT can still record optical pulses. This phenomenon is more pronounced for small curvature tip. These conclusions provide a basis for on-site GIS PD online monitoring and insulation status diagnosis, and highlight the necessity of synchronous gas state detection.
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
The Effect of Humidity on the Characteristics of Partial Discharge Induced by Metal Tip in GIS
Metal tip discharge is one of the most common types of partial discharge (PD) in gas-insulated switchgear (GIS) equipment. Understanding how humidity influences PD under actual operating conditions is of great significance for assessing insulation status accurately. This paper describes a GIS prototype test platform with controllable gas humidity. It integrates detection systems, including ultra-high frequency (UHF), photomultiplier tube (PMT), and spectrometer, to investigate the PD characteristics induced by metal tips with curvature radii of 200 μm and 75 μm under varying humidity conditions. The results indicate that with increasing humidity, the PD inception voltage (PDIV) for the 200 μm tip initially decreases, then rapidly increases after 480 μL/L and stabilizes. For the 75 μm tip, PDIV decreases quickly and then stabilizes, but with increased dispersion. In terms of discharge repetition rate, the negative polarity rate first increases and then decreases with humidity, reaching a maximum at 480 μL/L; the positive polarity rate, on the other hand, monotonically increases with humidity and exhibits an earlier inception. In terms of discharge amplitude, both negative and positive polarity amplitudes gradually decrease with increasing humidity. Under high humidity conditions, UHF signals are prone to falling below the detection threshold, resulting in non-detection, whereas PMT can still record optical pulses. This phenomenon is more pronounced for small curvature tip. These conclusions provide a basis for on-site GIS PD online monitoring and insulation status diagnosis, and highlight the necessity of synchronous gas state detection.
- Open Access
- 18 August 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (4) , 845-855
Gas‐insulated switchgear partial discharge classification method based on deep transfer learning using experimental and field data
Gas‐insulated switchgear (GIS) plays a critical role in ensuring the reliability of power systems, but partial discharge (PD) is a primary cause of failures within GIS equipment. Traditional PD diagnostic methods rely heavily on laboratory data, which differ significantly from that under the complex conditions of field data, leading to a marked drop in recognition accuracy when they are applied to field PD diagnosis. This study addresses the challenge by integrating field data into the training process, utilising a deep transfer learning approach that combines laboratory and field data to improve diagnostic accuracy for GIS PD. The research collected PD data from laboratory models representing five defect types and field data gathered from operational GIS equipment. A deep residual network (ResNet50) was pretrained using laboratory data and fine‐tuned with field data through deep transfer learning to optimise the recognition of PD in field conditions. The results show that the proposed model achieves a significantly higher recognition accuracy (93.7%) for field data compared to traditional methods (60%–70%). The integration of deep transfer learning ensures that both low‐dimensional general features from laboratory data and high‐dimensional specific features from field data are effectively utilised. This research significantly contributes to improving the diagnostic accuracy of PD in GIS under field conditions, providing a robust method for defect detection in operational equipment.
- 18 August 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (4) , 845-855
Open AccessGas‐insulated switchgear partial discharge classification method based on deep transfer learning using experimental and field data
Gas‐insulated switchgear (GIS) plays a critical role in ensuring the reliability of power systems, but partial discharge (PD) is a primary cause of failures within GIS equipment. Traditional PD diagnostic methods rely heavily on laboratory data, which differ significantly from that under the complex conditions of field data, leading to a marked drop in recognition accuracy when they are applied to field PD diagnosis. This study addresses the challenge by integrating field data into the training process, utilising a deep transfer learning approach that combines laboratory and field data to improve diagnostic accuracy for GIS PD. The research collected PD data from laboratory models representing five defect types and field data gathered from operational GIS equipment. A deep residual network (ResNet50) was pretrained using laboratory data and fine‐tuned with field data through deep transfer learning to optimise the recognition of PD in field conditions. The results show that the proposed model achieves a significantly higher recognition accuracy (93.7%) for field data compared to traditional methods (60%–70%). The integration of deep transfer learning ensures that both low‐dimensional general features from laboratory data and high‐dimensional specific features from field data are effectively utilised. This research significantly contributes to improving the diagnostic accuracy of PD in GIS under field conditions, providing a robust method for defect detection in operational equipment.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1391-1399
Motion and Discharge Characteristics of Mixed Submillimeter Metal Particles and Diverse Insulating Impurities Under AC Voltages
Submillimeter metal particles and insulating impurities are introduced during the operation of gas insulated switchgear (GIS), forming mixed particles that pose localized insulation weaknesses and compromise dielectric integrity. This study investigates the motion and discharge behaviors of such mixed particles and evaluates their impact on insulation performance. An experimental platform combining an AC voltage source with a simultaneous motion and partial discharge (PD) detection system is developed. Metal particles are mixed with five representative impurities, including adsorbent powder, closing resistor powder, glass fibers, insulating paint flakes, and rubber granules. Their motion and discharge characteristics are systematically recorded and analyzed. Polarization effects and charge accumulation are considered in interpreting the observed behaviors. The relative threat levels are evaluated using onset voltage, phase-resolved PD (PRPD) patterns, maximum PD amplitude, and PD repetition rate. Results show that mixing with adsorbent powder reduces discharge risk, reflected by a low comprehensive threat score of S = 0.1495. In contrast, other impurities increase the risk to varying degrees: closing resistor powder and insulating paint flakes cause mild effects with scores of 0.4287 and 0.3856, respectively; rubber granules have a moderate impact with S = 0.6415; while glass fibers pose the greatest threat with a score of 1.0. These conclusions provide a theoretical basis for early insulation defect detection in GIS.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1391-1399
Motion and Discharge Characteristics of Mixed Submillimeter Metal Particles and Diverse Insulating Impurities Under AC Voltages
Submillimeter metal particles and insulating impurities are introduced during the operation of gas insulated switchgear (GIS), forming mixed particles that pose localized insulation weaknesses and compromise dielectric integrity. This study investigates the motion and discharge behaviors of such mixed particles and evaluates their impact on insulation performance. An experimental platform combining an AC voltage source with a simultaneous motion and partial discharge (PD) detection system is developed. Metal particles are mixed with five representative impurities, including adsorbent powder, closing resistor powder, glass fibers, insulating paint flakes, and rubber granules. Their motion and discharge characteristics are systematically recorded and analyzed. Polarization effects and charge accumulation are considered in interpreting the observed behaviors. The relative threat levels are evaluated using onset voltage, phase-resolved PD (PRPD) patterns, maximum PD amplitude, and PD repetition rate. Results show that mixing with adsorbent powder reduces discharge risk, reflected by a low comprehensive threat score of S = 0.1495. In contrast, other impurities increase the risk to varying degrees: closing resistor powder and insulating paint flakes cause mild effects with scores of 0.4287 and 0.3856, respectively; rubber granules have a moderate impact with S = 0.6415; while glass fibers pose the greatest threat with a score of 1.0. These conclusions provide a theoretical basis for early insulation defect detection in GIS.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3548-3555
Effect of Temperature on Characteristics of Surface Partial Discharge Induced by Metal Particles in GIS
Surface discharge along insulators is one of the primary causes of gas insulated switchgear (GIS) failures, with temperature variations caused by load fluctuations further affecting insulation performance. This study developed a GIS temperature control system based on oil circulation to simulate actual thermal conditions and investigated the inception and development characteristics of surface partial discharge (PD) under varying temperatures. Metallic defects were introduced on the insulator surface to initiate discharges, and the results showed that increasing temperature lowers the PD inception voltage, significantly increases the discharge repetition rate, and accelerates the transition between discharge modes. Elevated temperature also causes the amplitude-frequency distribution curves to shift toward higher amplitudes at the same voltage. On the one hand, the non-uniform temperature rises within GIS result in an uneven distribution of gas density, thereby weakening the insulation strength. On the other hand, elevated temperatures enhance the mechanisms of initial electron generation, charge decay, and secondary electron emission, further promoting the development of discharge processes. This study highlights the effect of temperature on GIS surface PD inception and development characteristics.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3548-3555
Effect of Temperature on Characteristics of Surface Partial Discharge Induced by Metal Particles in GIS
Surface discharge along insulators is one of the primary causes of gas insulated switchgear (GIS) failures, with temperature variations caused by load fluctuations further affecting insulation performance. This study developed a GIS temperature control system based on oil circulation to simulate actual thermal conditions and investigated the inception and development characteristics of surface partial discharge (PD) under varying temperatures. Metallic defects were introduced on the insulator surface to initiate discharges, and the results showed that increasing temperature lowers the PD inception voltage, significantly increases the discharge repetition rate, and accelerates the transition between discharge modes. Elevated temperature also causes the amplitude-frequency distribution curves to shift toward higher amplitudes at the same voltage. On the one hand, the non-uniform temperature rises within GIS result in an uneven distribution of gas density, thereby weakening the insulation strength. On the other hand, elevated temperatures enhance the mechanisms of initial electron generation, charge decay, and secondary electron emission, further promoting the development of discharge processes. This study highlights the effect of temperature on GIS surface PD inception and development characteristics.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3540-3547
Surface Partial Discharge Characteristics of GIS Under AC and Superimposed Switching Impulse Voltage
The attachment of metal particles on the surface of insulators is a significant source of surface discharges and operational failures in gas insulated switchgear (GIS). This study systematically investigated the characteristics of surface partial discharge (PD) under both AC voltage and AC superimposed switching impulse voltage, verifying the feasibility of monitoring PDs during switching operations to detect surface defects within GIS. The development of surface PD under AC voltage can be categorized into three stages with relatively low discharge amplitudes observed in the initial two stages. Surface PDs can only be effectively measured using ultra-high frequency (UHF) and optical devices once PD progression becomes pronounced. When switching impulses with an amplitude of 2.2 times AC voltage were superimposed at various AC phases, sustained and high-amplitude PDs were induced following the impulses, even when the AC voltage remains below the PD inception voltage. Space and surface charge introduced by PDs under switching impulse distort the electric field, thereby triggering subsequent discharges. The amplitude and duration of PDs excited by superimposed impulse voltage are adequate for UHF detection. This finding suggests the potential for timely detection of surface defects in GIS by monitoring PD conditions during switchgear operation.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3540-3547
Surface Partial Discharge Characteristics of GIS Under AC and Superimposed Switching Impulse Voltage
The attachment of metal particles on the surface of insulators is a significant source of surface discharges and operational failures in gas insulated switchgear (GIS). This study systematically investigated the characteristics of surface partial discharge (PD) under both AC voltage and AC superimposed switching impulse voltage, verifying the feasibility of monitoring PDs during switching operations to detect surface defects within GIS. The development of surface PD under AC voltage can be categorized into three stages with relatively low discharge amplitudes observed in the initial two stages. Surface PDs can only be effectively measured using ultra-high frequency (UHF) and optical devices once PD progression becomes pronounced. When switching impulses with an amplitude of 2.2 times AC voltage were superimposed at various AC phases, sustained and high-amplitude PDs were induced following the impulses, even when the AC voltage remains below the PD inception voltage. Space and surface charge introduced by PDs under switching impulse distort the electric field, thereby triggering subsequent discharges. The amplitude and duration of PDs excited by superimposed impulse voltage are adequate for UHF detection. This finding suggests the potential for timely detection of surface defects in GIS by monitoring PD conditions during switchgear operation.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1557-1566
Aggregation Characteristics of Cellulose Particles of Different Sizes in Transformer Oil Under DC Electric Field
Under DC electric field, the migration and accumulation of cellulose particles in transformer oil will affect the oil insulation strength, thus threatening the normal operation of the converter transformer. In this work, a cellulose particle behavior observation platform is constructed, and the behavioral characteristics of cellulose particles of different particle sizes in transformer oil are analyzed through experimental and theoretical comparisons. The results show that the particle chains formed by large-sized cellulose particles extend relatively faster on the electrode surface, with relatively longer length and sparser distribution, making it easier to form stable cellulose bridges within the oil gap. Correspondingly, small-sized cellulose particles are difficult to form stable cellulose bridges in the oil gap. The increase in cellulose particle concentration has limited impact on the length of particle chains, thus it remains challenging for small particles with higher concentrations to form bridges. The external field force primarily influences the movement of particles between the electrodes, while the inter-particle force mainly impacts the aggregation effect of the particles. Dipole interactions dominate in the formation of particle chains and are relatively stronger between ellipsoidal particles.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1557-1566
Aggregation Characteristics of Cellulose Particles of Different Sizes in Transformer Oil Under DC Electric Field
Under DC electric field, the migration and accumulation of cellulose particles in transformer oil will affect the oil insulation strength, thus threatening the normal operation of the converter transformer. In this work, a cellulose particle behavior observation platform is constructed, and the behavioral characteristics of cellulose particles of different particle sizes in transformer oil are analyzed through experimental and theoretical comparisons. The results show that the particle chains formed by large-sized cellulose particles extend relatively faster on the electrode surface, with relatively longer length and sparser distribution, making it easier to form stable cellulose bridges within the oil gap. Correspondingly, small-sized cellulose particles are difficult to form stable cellulose bridges in the oil gap. The increase in cellulose particle concentration has limited impact on the length of particle chains, thus it remains challenging for small particles with higher concentrations to form bridges. The external field force primarily influences the movement of particles between the electrodes, while the inter-particle force mainly impacts the aggregation effect of the particles. Dipole interactions dominate in the formation of particle chains and are relatively stronger between ellipsoidal particles.
- 29 September 2024
- Published by Elsevier in Measurement
- Vol. 242
Design and optimization for GIS UHF-Overvoltage composite sensor
- 29 September 2024
- Published by Elsevier in Measurement
- Vol. 242
Design and optimization for GIS UHF-Overvoltage composite sensor
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Fast Self-Calibration Method for Piezoelectric Sensors Excited by Pseudorandom M-Sequence
Piezoelectric element is the most critical component of a piezoelectric sensor, commonly applied for defect detection of electrical equipment. To ensure the sensor work stably and reliably, impedance and sensitivity response curves should be calibrated periodically with specific technical platforms in laboratory to evaluate the sensor’s performance and characteristics. This is costly, time-consuming and inconvenient for industrial measurements. Pseudorandom M-sequence is a kind of binary signal that exhibits statistical characteristics similar to white noise. This paper proposes a fast self-calibration method based on pseudorandom M-sequence, which is suitable for acquiring the impedance and sensitivity response curves of piezoelectric sensors. The clock pulse frequency of M-sequence can be adjusted to match the calibration band. The simulation and experimental results confirm that this method is feasible, reliable and efficient in terms of both power and time consumption, requiring a few milliseconds and approximately 10 mW for a single calibration. The method was successfully applied in a commercial AE sensor and a recently-developed wireless piezoelectric sensor. This work provides a novel solution for the self-calibration of smart piezoelectric sensors.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Fast Self-Calibration Method for Piezoelectric Sensors Excited by Pseudorandom M-Sequence
Piezoelectric element is the most critical component of a piezoelectric sensor, commonly applied for defect detection of electrical equipment. To ensure the sensor work stably and reliably, impedance and sensitivity response curves should be calibrated periodically with specific technical platforms in laboratory to evaluate the sensor’s performance and characteristics. This is costly, time-consuming and inconvenient for industrial measurements. Pseudorandom M-sequence is a kind of binary signal that exhibits statistical characteristics similar to white noise. This paper proposes a fast self-calibration method based on pseudorandom M-sequence, which is suitable for acquiring the impedance and sensitivity response curves of piezoelectric sensors. The clock pulse frequency of M-sequence can be adjusted to match the calibration band. The simulation and experimental results confirm that this method is feasible, reliable and efficient in terms of both power and time consumption, requiring a few milliseconds and approximately 10 mW for a single calibration. The method was successfully applied in a commercial AE sensor and a recently-developed wireless piezoelectric sensor. This work provides a novel solution for the self-calibration of smart piezoelectric sensors.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Partial discharge detection, diagnosis, and location technology based on a novel transient earth voltage-ultrasonic integrated sensor used for switchgear equipment
Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users. However, insulation faults often occur during the operation of MV switchgear and GIS because of pollution, humidity, heat, mechanical shock, and other factors. Partial discharge (PD) measurements are the most effective indicator to prevent insulation failure. Transient earth voltage (TEV) and ultrasonic methods are the most popular PD measurement methods for switchgear. Currently, these two methods are used widely and independently. In this study, a novel TEV-ultrasonic integrated sensor is proposed based on the independent structure of the TEV and the ultrasonic sensor. The performance parameters of the proposed sensor were tested on test platforms. PD measurement experiments were conducted in a 10 kV switchgear and 220 kV GIS to analyze the performance of the integrated sensor. The results show that the sensor can simultaneously measure the TEV and ultrasonic signals in the same location. The integrated sensor can realize effective and sensitive detection, precise location, and accurate diagnosis of PD in the MV switchgear and GIS.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Partial discharge detection, diagnosis, and location technology based on a novel transient earth voltage-ultrasonic integrated sensor used for switchgear equipment
Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users. However, insulation faults often occur during the operation of MV switchgear and GIS because of pollution, humidity, heat, mechanical shock, and other factors. Partial discharge (PD) measurements are the most effective indicator to prevent insulation failure. Transient earth voltage (TEV) and ultrasonic methods are the most popular PD measurement methods for switchgear. Currently, these two methods are used widely and independently. In this study, a novel TEV-ultrasonic integrated sensor is proposed based on the independent structure of the TEV and the ultrasonic sensor. The performance parameters of the proposed sensor were tested on test platforms. PD measurement experiments were conducted in a 10 kV switchgear and 220 kV GIS to analyze the performance of the integrated sensor. The results show that the sensor can simultaneously measure the TEV and ultrasonic signals in the same location. The integrated sensor can realize effective and sensitive detection, precise location, and accurate diagnosis of PD in the MV switchgear and GIS.