Xiaohui Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaohui Song has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Fei Gao
Shanghai Jiao Tong University
1 shared publication - Hua Liu
School of Electronic Engineering, Nanjing Xiaozhuang University, No. 3601 Honhjing Avenue, Jiangning District, Nanjing 211171, China
1 shared publication - Jianlong Li
School of Control and Computer Engineering, North China Electric Power University, Beijing, China
1 shared publication - Liwei Xie
School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410114, China
1 shared publication - Qiang Zhang
School of Mines, China University of Mining & Technology, Xuzhou 221116, China
1 shared publication - Shanshan Zhao
Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 27 June 2023
- Published by Wiley
Identification Method and Device for Single-Phase-to-Ground Fault Based on Electric Field Variation in Small-Current Grounded Distribution Systems
Considering the low identification accuracy of single-phase-to-ground(SLG) fault in distribution systems with the neural point small-current grounded, breaking through the traditional fault identification method based on voltage or current, this paper focuses on mining the features of electric field variation when SLG fault occurs. Firstly, based on the charge simulation method, the electric field at the same height under three-phase distribution lines and that on the line surface during SLG fault are respectively calculated. Accordingly, the variation law of electric field in small-current grounded distribution systems during SLG fault is obtained theoretically, and the corresponding relationship between the variation mode of electric field and the occurrence of SLG fault is established. Besides, MEMS sensor is innovatively adopted for electric field measurement in distribution systems by taking advantage of its small size, low power consumption and high accuracy, and its integration scheme with fault indicator is formed. On this basis, a SLG fault identification method and corresponding devices based on the variation of electric field are proposed, and the effectiveness is verified by experiments.
- 27 June 2023
- Published by Wiley
Open AccessIdentification Method and Device for Single-Phase-to-Ground Fault Based on Electric Field Variation in Small-Current Grounded Distribution Systems
Considering the low identification accuracy of single-phase-to-ground(SLG) fault in distribution systems with the neural point small-current grounded, breaking through the traditional fault identification method based on voltage or current, this paper focuses on mining the features of electric field variation when SLG fault occurs. Firstly, based on the charge simulation method, the electric field at the same height under three-phase distribution lines and that on the line surface during SLG fault are respectively calculated. Accordingly, the variation law of electric field in small-current grounded distribution systems during SLG fault is obtained theoretically, and the corresponding relationship between the variation mode of electric field and the occurrence of SLG fault is established. Besides, MEMS sensor is innovatively adopted for electric field measurement in distribution systems by taking advantage of its small size, low power consumption and high accuracy, and its integration scheme with fault indicator is formed. On this basis, a SLG fault identification method and corresponding devices based on the variation of electric field are proposed, and the effectiveness is verified by experiments.
- Open Access
- 2 May 2023
- Published by Institution of Engineering and Technology (IET) in IET Cyber-Physical Systems: Theory & Applications
- Vol. 8 (3) , 205-217
Research on eigenparameters and detection methods for single‐phase‐to‐ground faults in non‐effectively grounded distribution systems
Non‐effectively grounded power distribution systems (NGDS) are widely used in China and other countries. However, over a long time, single‐phase‐to‐ground faults (SGF) have been misjudged or omitted by the monitoring system, threatening the security of the power supply system and human safety. Based on the reason analysis for the omitted and misjudged SGFs in NGDS, the concept of NGDS fault eigenparameters to correctly reflect fault characteristics and a method of SGF detection based on fault eigenparameters are proposed. Then, the detection mechanism of phase voltage and fault current resistive elements for SGF is revealed. The variation characteristics of typical fault parameters changing with distribution system scale (parameter) and fault transition resistance, such as residual voltage and Zero‐sequence current (iA‐iO), are analysed. The eigenparameters of SGF in certain NGDS with specific scales/parameters are also proposed, which can correctly reflect the fault characteristics under different transition resistances.
- 2 May 2023
- Published by Institution of Engineering and Technology (IET) in IET Cyber-Physical Systems: Theory & Applications
- Vol. 8 (3) , 205-217
Open AccessResearch on eigenparameters and detection methods for single‐phase‐to‐ground faults in non‐effectively grounded distribution systems
Non‐effectively grounded power distribution systems (NGDS) are widely used in China and other countries. However, over a long time, single‐phase‐to‐ground faults (SGF) have been misjudged or omitted by the monitoring system, threatening the security of the power supply system and human safety. Based on the reason analysis for the omitted and misjudged SGFs in NGDS, the concept of NGDS fault eigenparameters to correctly reflect fault characteristics and a method of SGF detection based on fault eigenparameters are proposed. Then, the detection mechanism of phase voltage and fault current resistive elements for SGF is revealed. The variation characteristics of typical fault parameters changing with distribution system scale (parameter) and fault transition resistance, such as residual voltage and Zero‐sequence current (iA‐iO), are analysed. The eigenparameters of SGF in certain NGDS with specific scales/parameters are also proposed, which can correctly reflect the fault characteristics under different transition resistances.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 63, 961-964
Installation Technology of Vector Adjustment Mechanism for Electric Propulsion System in Spacecraft
In view of the small installation and operation space of the satellite electric propulsion vector adjustment mechanism unlocker of the communication platform, the installation process is complicated, and the pressing gap requirements are strict. This article summarizes and refines the installation and operation skills of the vector adjustment mechanism unlocker and the pressing gap control method. The realization of quantitative control has been successfully applied in the model development, ensuring the high reliability of the vector adjustment mechanism and meeting the requirements of on-orbit work.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 63, 961-964
Installation Technology of Vector Adjustment Mechanism for Electric Propulsion System in Spacecraft
In view of the small installation and operation space of the satellite electric propulsion vector adjustment mechanism unlocker of the communication platform, the installation process is complicated, and the pressing gap requirements are strict. This article summarizes and refines the installation and operation skills of the vector adjustment mechanism unlocker and the pressing gap control method. The realization of quantitative control has been successfully applied in the model development, ensuring the high reliability of the vector adjustment mechanism and meeting the requirements of on-orbit work.
- Open Access
- 1 January 2020
- Published by Power System Technology Press in CSEE Journal of Power and Energy Systems
- Vol. 8 (2) , 591-598
Vulnerable point identification using heterogeneous interdependent node theory for distribution system
- 1 January 2020
- Published by Power System Technology Press in CSEE Journal of Power and Energy Systems
- Vol. 8 (2) , 591-598
Open AccessVulnerable point identification using heterogeneous interdependent node theory for distribution system
- Open Access
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 486 (1) , 012064
A New Distribution Network Structure for Maximizing the Allowable Penetration of Distributed Energy Resource
The traditional network structure cannot be suitable for the connection of large-scale distributed energy resources, thus the high penetration of distributed energy resource (DER) will have destructive effects on the security and reliability of the traditional distribution network. The paper proposes a new distribution network structure to increase the maximum allowable penetration of DER. Firstly, the model and method of the new distribution network structure are presented. Secondly, the theory basis of increasing the DER penetration by the new network structure is proved. Finally, the proposed model and method are applied to the typical test case. And the simulation results show that compared with the traditional structure, the new distribution network structure can not only increase the maximum penetration of distributed energy resource greatly, but also realize the high energy efficiency, reliability and sustainability. Therefore, the issue of future distribution network security with high penetration of distributed energy resource can be well solved by the new distribution network structure proposed in the paper.
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 486 (1) , 012064
Open AccessA New Distribution Network Structure for Maximizing the Allowable Penetration of Distributed Energy Resource
The traditional network structure cannot be suitable for the connection of large-scale distributed energy resources, thus the high penetration of distributed energy resource (DER) will have destructive effects on the security and reliability of the traditional distribution network. The paper proposes a new distribution network structure to increase the maximum allowable penetration of DER. Firstly, the model and method of the new distribution network structure are presented. Secondly, the theory basis of increasing the DER penetration by the new network structure is proved. Finally, the proposed model and method are applied to the typical test case. And the simulation results show that compared with the traditional structure, the new distribution network structure can not only increase the maximum penetration of distributed energy resource greatly, but also realize the high energy efficiency, reliability and sustainability. Therefore, the issue of future distribution network security with high penetration of distributed energy resource can be well solved by the new distribution network structure proposed in the paper.