Research on eigenparameters and detection methods for single‐phase‐to‐ground faults in non‐effectively grounded distribution systems
Authors:
Open Access
- 2 May 2023
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Cyber-Physical Systems: Theory & Applications
- Vol. 8 (3) , 205-217
Abstract
Non‐effectively grounded power distribution systems (NGDS) are widely used in China and other countries. However, over a long time, single‐phase‐to‐ground faults (SGF) have been misjudged or omitted by the monitoring system, threatening the security of the power supply system and human safety. Based on the reason analysis for the omitted and misjudged SGFs in NGDS, the concept of NGDS fault eigenparameters to correctly reflect fault characteristics and a method of SGF detection based on fault eigenparameters are proposed. Then, the detection mechanism of phase voltage and fault current resistive elements for SGF is revealed. The variation characteristics of typical fault parameters changing with distribution system scale (parameter) and fault transition resistance, such as residual voltage and Zero‐sequence current (iA‐iO), are analysed. The eigenparameters of SGF in certain NGDS with specific scales/parameters are also proposed, which can correctly reflect the fault characteristics under different transition resistances.Keywords
This publication has 19 references indexed in Scilit:
- Smart Transformer-Based Single Phase-To-Neutral Fault ManagementIEEE Transactions on Power Delivery, 2019
- A Decentralized Fault Detection Technique for Detecting Single Phase to Ground Faults in Power Distribution Systems With Resonant GroundingIEEE Transactions on Power Delivery, 2018
- Detecting Single-Phase-to-Ground Fault Event and Identifying Faulty Feeder in Neutral Ineffectively Grounded Distribution SystemIEEE Transactions on Power Delivery, 2017
- A Novel Line Protection Scheme for a Single Phase-to-Ground Fault Based on Voltage Phase ComparisonIEEE Transactions on Power Delivery, 2015
- Traveling wave based single-phase-to-ground protection method for power distribution systemCSEE Journal of Power and Energy Systems, 2015
- Stator Single-Phase-to-Ground Fault Protection for Bus-connected Powerformers Based on Hierarchical Clustering AlgorithmIEEE Transactions on Energy Conversion, 2013
- Studies on the Stator Single-Phase-to-Ground Fault Protection for a High-Voltage Cable-Wound GeneratorIEEE Transactions on Energy Conversion, 2013
- Novel Identification Method of Stator Single Phase-to-Ground Fault for Cable-Wound GeneratorsIEEE Transactions on Energy Conversion, 2008
- Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral systemIEEE Transactions on Power Delivery, 1998
- Single-line-to-ground fault test of a 3-phase superconducting fault current limiting reactorIEEE Transactions on Magnetics, 1992