Bin Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bin Cai has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Tianhao Cheng
School of Information and Navigation, Air Force Engineering University, Xian, China
2 shared publications - Biling Wang
Medical Artificial Intelligence and Automation (MAIA) Laboratory and Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America
1 shared publication - Buhong Wang
Air Force Engineering University
1 shared publication - Dan Nguyen
Medical Artificial Intelligence and Automation Laboratory Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA
1 shared publication Fengping Yang
CNPC Tubular Goods Research Institute (China)
1 shared publication- Hongbo Zhang
Stage Key Laboratory for Powder Metallurgy, Central South University, Changsha, 410083, China
1 shared publication
Latest Publications
- Open Access
- 8 May 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (9) , 2467
A Priori Knowledge Based Ground Moving Target Indication Technique Applied to Distributed Spaceborne SAR System
Through formation flying, the distributed spaceborne SAR(synthetic aperture radar) system can increase the number of spatial degree of freedoms (DOFs) and provide flexible multi-baselines for SAR-GMTI (ground moving target indication), which improves the system performance. This paper proposes an a priori knowledge-based adaptive clutter cancellation and moving target detection technique applied to the distributed spaceborne SAR-GMTI systems. Firstly, the adaptive clutter cancellation technique is exploited to suppress the ground clutter. A priori knowledge, such as road network information, is integrated to the adaptive clutter cancellation processor to reduce any moving target steering vector mismatch. Secondly, adaptive matched filter (AMF) and adaptive beamformer orthogonal rejection test (ABORT) are exploited as adaptive detection techniques for moving target detection. Due to the dense road network, the moving target steering vector estimation may be ambiguous for the different position and orientation of the roads. The multiple hypothesis testing (MHT) technique is proposed to detect the moving targets and resolve the potential ambiguities. A scheme is exploited to detect, classify, and relocate the moving targets. Finally, simulation experiments and performance analysis have demonstrated the effectiveness and robustness of the proposed technique.
- 8 May 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (9) , 2467
Open AccessA Priori Knowledge Based Ground Moving Target Indication Technique Applied to Distributed Spaceborne SAR System
Through formation flying, the distributed spaceborne SAR(synthetic aperture radar) system can increase the number of spatial degree of freedoms (DOFs) and provide flexible multi-baselines for SAR-GMTI (ground moving target indication), which improves the system performance. This paper proposes an a priori knowledge-based adaptive clutter cancellation and moving target detection technique applied to the distributed spaceborne SAR-GMTI systems. Firstly, the adaptive clutter cancellation technique is exploited to suppress the ground clutter. A priori knowledge, such as road network information, is integrated to the adaptive clutter cancellation processor to reduce any moving target steering vector mismatch. Secondly, adaptive matched filter (AMF) and adaptive beamformer orthogonal rejection test (ABORT) are exploited as adaptive detection techniques for moving target detection. Due to the dense road network, the moving target steering vector estimation may be ambiguous for the different position and orientation of the roads. The multiple hypothesis testing (MHT) technique is proposed to detect the moving targets and resolve the potential ambiguities. A scheme is exploited to detect, classify, and relocate the moving targets. Finally, simulation experiments and performance analysis have demonstrated the effectiveness and robustness of the proposed technique.
- 2 November 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12351, 399-404
Quality inspection and defect analysis of a batch of long radius elbows for oil and gas transportation
Given the quality problem of a batch of oil and gas long radius elbow found on site, a quality sampling inspection was carried out. The quality was tested by a penetrant test, geometric dimensions measurement, chemical composition analysis, and a hardness test. Metallographic analysis was carried out about the defects found. It can be seen that no obvious abnormality was found in the profile size, remaining wall thickness, chemical composition analysis, and hardness test results of this batch of elbows. There is a longitudinal crack with a length of 10 mm on the outer surface of the pipe end of the DN50 elbow. According to anatomical analysis, this defect is a shallow crack on the outer surface, with a certain angle between the crack and the outer surface of the pipe. The maximum depth in the cross-section is 0.24 mm, and the vertical depth from the outer surface is 0.12 mm. It is speculated that these cracks occurred before solution treatment and are related to the original defects of the parent pipe or mechanical damage during cold work.
- 2 November 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12351, 399-404
Quality inspection and defect analysis of a batch of long radius elbows for oil and gas transportation
Given the quality problem of a batch of oil and gas long radius elbow found on site, a quality sampling inspection was carried out. The quality was tested by a penetrant test, geometric dimensions measurement, chemical composition analysis, and a hardness test. Metallographic analysis was carried out about the defects found. It can be seen that no obvious abnormality was found in the profile size, remaining wall thickness, chemical composition analysis, and hardness test results of this batch of elbows. There is a longitudinal crack with a length of 10 mm on the outer surface of the pipe end of the DN50 elbow. According to anatomical analysis, this defect is a shallow crack on the outer surface, with a certain angle between the crack and the outer surface of the pipe. The maximum depth in the cross-section is 0.24 mm, and the vertical depth from the outer surface is 0.12 mm. It is speculated that these cracks occurred before solution treatment and are related to the original defects of the parent pipe or mechanical damage during cold work.
- Open Access
- 1 July 2022
- Published by Comprehensive Publications in International Journal of Surgery Science
- Vol. 6 (3) , 92-95
Groove chest: An independent thoracic deformity
Thoracic deformity can be roughly divided into two categories, one is depression deformity the other is protrusion deformity. In general, depression deformity is called pectus excavatum. In the era of open surgery, there is no big problem with this nomenclature. However, in the era of minimally invasive surgery, because the general minimally invasive surgery cannot be used to treat some depression deformities, it is necessary to further classify these deformities. After a long time observations, we found that there was a type of deformity with distinct characteristics, which was the transverse groove in the anterior chest wall, and was significantly different from the hollow of the typical pectus excavatum. This deformity cannot be corrected with standard Nuss procedure. In order to better understand and treat this special deformity, we named it groove chest. We also made a special design for its operation, and finally designed an effective surgical method. Our experience shows that the surgery we designed is an effective technique, which also proves the necessity of treating groove chest as an independent deformity.
- 1 July 2022
- Published by Comprehensive Publications in International Journal of Surgery Science
- Vol. 6 (3) , 92-95
Open AccessGroove chest: An independent thoracic deformity
Thoracic deformity can be roughly divided into two categories, one is depression deformity the other is protrusion deformity. In general, depression deformity is called pectus excavatum. In the era of open surgery, there is no big problem with this nomenclature. However, in the era of minimally invasive surgery, because the general minimally invasive surgery cannot be used to treat some depression deformities, it is necessary to further classify these deformities. After a long time observations, we found that there was a type of deformity with distinct characteristics, which was the transverse groove in the anterior chest wall, and was significantly different from the hollow of the typical pectus excavatum. This deformity cannot be corrected with standard Nuss procedure. In order to better understand and treat this special deformity, we named it groove chest. We also made a special design for its operation, and finally designed an effective surgical method. Our experience shows that the surgery we designed is an effective technique, which also proves the necessity of treating groove chest as an independent deformity.
- Open Access
Region Specific Optimization (RSO)-based Deep Interactive Registration
Medical image registration is a fundamental and vital task which will affect the efficacy of many downstream clinical tasks. Deep learning (DL)-based deformable image registration (DIR) methods have been investigated, showing state-of-the-art performance. A test time optimization (TTO) technique was proposed to further improve the DL models' performance. Despite the substantial accuracy improvement with this TTO technique, there still remained some regions that exhibited large registration errors even after many TTO iterations. To mitigate this challenge, we firstly identified the reason why the TTO technique was slow, or even failed, to improve those regions' registration results. We then proposed a two-levels TTO technique, i.e., image-specific optimization (ISO) and region-specific optimization (RSO), where the region can be interactively indicated by the clinician during the registration result reviewing process. For both efficiency and accuracy, we further envisioned a three-step DL-based image registration workflow. Experimental results showed that our proposed method outperformed the conventional method qualitatively and quantitatively.
Open AccessRegion Specific Optimization (RSO)-based Deep Interactive Registration
Medical image registration is a fundamental and vital task which will affect the efficacy of many downstream clinical tasks. Deep learning (DL)-based deformable image registration (DIR) methods have been investigated, showing state-of-the-art performance. A test time optimization (TTO) technique was proposed to further improve the DL models' performance. Despite the substantial accuracy improvement with this TTO technique, there still remained some regions that exhibited large registration errors even after many TTO iterations. To mitigate this challenge, we firstly identified the reason why the TTO technique was slow, or even failed, to improve those regions' registration results. We then proposed a two-levels TTO technique, i.e., image-specific optimization (ISO) and region-specific optimization (RSO), where the region can be interactively indicated by the clinician during the registration result reviewing process. For both efficiency and accuracy, we further envisioned a three-step DL-based image registration workflow. Experimental results showed that our proposed method outperformed the conventional method qualitatively and quantitatively.
- 31 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (12) , 13200-13214
Lightweight CNNs-Based Interleaved Sparse Array Design of Phased-MIMO Radar
Conventional transmit subarray partitioning schemes of phased-MIMO radar will cause several problems, the reduction of array aperture, the increase of feeding network complexity and optimization algorithms time cost. Focus on the problems above, this paper proposes a deep learning-based interleaved sparse transmit subarray partitioning method. Firstly, the training data is generated by phased-MIMO array manifold matrix. Secondly, a dimensionality reduction method for radar data is introduced to reduce the dimensionality of the sample data while minimizing information loss. Then, a lightweight convolutional neural network is constructed for training and the optimal array structures is selected by classification. Finally, linear and plane arrays experiment results show that our proposed method can achieve 97.95% classification accuracy, better than other conventional dimensionality reduction methods and neural networks; compared with the traditional SCP partitioning method, our proposed method has similar beampattern sidelobe level and DOA estimation accuracy, but the time cost is greatly reduced.
- 31 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (12) , 13200-13214
Lightweight CNNs-Based Interleaved Sparse Array Design of Phased-MIMO Radar
Conventional transmit subarray partitioning schemes of phased-MIMO radar will cause several problems, the reduction of array aperture, the increase of feeding network complexity and optimization algorithms time cost. Focus on the problems above, this paper proposes a deep learning-based interleaved sparse transmit subarray partitioning method. Firstly, the training data is generated by phased-MIMO array manifold matrix. Secondly, a dimensionality reduction method for radar data is introduced to reduce the dimensionality of the sample data while minimizing information loss. Then, a lightweight convolutional neural network is constructed for training and the optimal array structures is selected by classification. Finally, linear and plane arrays experiment results show that our proposed method can achieve 97.95% classification accuracy, better than other conventional dimensionality reduction methods and neural networks; compared with the traditional SCP partitioning method, our proposed method has similar beampattern sidelobe level and DOA estimation accuracy, but the time cost is greatly reduced.