YSYun Shang

Yun Shang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yun Shang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation of B0 magnetic field conditions in the human heart for improved diagnostic MRI

    by Yun Shang, Sebastian Theilenberg, Michelle Castillo, Boyu Peng, Maggie Fung, Patrick Quarterman, Benjamin Navot, Sachin R. Jambawalikar, Andrew J. Einstein, Christoph Juchem


  • B0 Magnetic Field Conditions in the Human Heart at 3 T Across One Thousand Subjects: A Numerical Simulation Study

    by Yun Shang, Sebastian Theilenberg, Boyu Peng, Laura M. Schreiber, Andrew J. Einstein, Sachin R. Jambawalikar, Christoph Juchem

    Functional scans in cardiovascular magnetic resonance (CMR) adopting bSSFP sequences suffer from dark band artifacts due to B0 inhomogeneity. The best remedy to mitigate this issue is through cardiac B0 shimming. The development of an optimal B0 shim strategy for the human heart is hindered by a limited understanding of B0 conditions in clinical diagnostic orientations of CMR. Here, we present high‐resolution B0 distributions in cardiac imaging planes, derived from simulations utilizing high‐resolution computed tomography (CT) images from 1008 subjects, and present an oblique slicing method to derive such B0 distributions. This study also presents a theoretical analysis of spherical harmonic B0 shimming at 3 T using a static global approach and slice‐specific dynamic shim updating in the short‐axis view of human hearts. The characteristics of cardiac B0 conditions along with spherical harmonic shimming were correlated with the subjects' demographic parameters, with weak or no correlations, suggesting limited demographic commonality and predominantly subject‐specific characteristics in cardiac B0. The segmented lung volume shows more significant associations and relatively higher correlations with B0 conditions, indicating that B0 conditions in the heart rely on the anatomy surrounding the heart more than overall body shape and size. This research provides a basis for the development of optimized cardiac B0 shim strategies.


  • Open Access

    Fabrication of a 25.2 T NMR magnet for an extreme condition user facility in China

    by Hui Han, Yun Shang

    This article highlights a research study on the fabrication of a 25.2 T ultra-high field NMR magnet for an extreme condition user facility in China.


  • Open Access

    Advancements in MR hardware systems and magnetic field control: B0 shimming, RF coils, and gradient techniques for enhancing magnetic resonance imaging and spectroscopy

    by Yun Shang, Gizeaddis Lamesgin Simegn, Kelly Gillen, Hsin-Jung Yang, Hui Han

    High magnetic field homogeneity is critical for magnetic resonance imaging (MRI), functional MRI, and MR spectroscopy (MRS) applications. B0 inhomogeneity during MR scans is a long-standing problem resulting from magnet imperfections and site conditions, with the main issue being the inhomogeneity across the human body caused by differences in magnetic susceptibilities between tissues, resulting in signal loss, image distortion, and poor spectral resolution. Through a combination of passive and active shim techniques, as well as technological advances employing multi-coil techniques, optimal coil design, motion tracking, and real-time modifications, improved field homogeneity and image quality have been achieved in MRI/MRS. The integration of RF and shim coils brings a high shim efficiency due to the proximity of subjects. This technique will potentially be applied to high-density RF coils with a high-density shim array for improved B0 homogeneity. Simultaneous shimming and image encoding can be achieved using multi-coil array, which also enables the development of novel encoding methods using advanced magnetic field control. Field monitoring enables the capture and real-time compensation for dynamic field perturbance beyond the static background inhomogeneity. These advancements have the potential to better use the scanner performance to enhance diagnostic capabilities and broaden applications of MRI/MRS in a variety of clinical and research settings. The purpose of this paper is to provide an overview of the latest advances in B0 magnetic field shimming and magnetic field control techniques as well as MR hardware, emphasize their significance and potential impact on improving the data quality of MRI/MRS.


  • Open Access

    High resolution simulation and measurement demonstrate oscillatory spatiotemporal B0 fluctuations across the human cardiac cycle

    by Yun Shang, Sebastian Theilenberg, Martin Gajdošík, Laura M. Schreiber, Christoph Juchem

    Purpose: Functional cardiac MRI scans employing balanced steady‐state free precession sequences suffer from dark band artifacts in the myocardium due to B0 inhomogeneity. We recently introduced a novel method for the theoretical derivation of B0 distributions in the human heart. This study aims to simulate the B0 distributions in the heart across the cardiac cycle using structural MR images and validate the simulations via in vivo measured cardiac phase‐specific B0 maps on the same subjects at 3T.Methods: Cardiac phase‐specific B0 field maps were acquired from eight healthy subjects at 3T. B0 conditions were simulated based on tissue masks created from the cardiac‐phase specific structural images from the in vivo B0 map scan and anatomical images from a thoracic MRI scan, adopting our recently published approach. The simulations and in vivo measurements were compared by calculating the spatial correlation of their B0 distributions and temporal correlation of the derived spherical harmonic coefficients throughout the cardiac cycle.Results: The spatial comparison of B0 maps between the simulation and in vivo measurement indicates an overall average correlation coefficient of 0.91 across the cardiac cycle in all subjects. Both groups show consistent high‐level B0 patterns. Temporal variations of B0 conditions exhibit sinusoidal characteristics and are strongly correlated between simulation and in vivo.Conclusion: Theoretical simulations employing regional anatomical features were validated by direct in vivo B0 mapping in the same subjects. The spatial B0 condition throughout the cardiac cycle exhibits oscillatory characteristics due to structural distortions of cardiac motion.


  • Open Access

    Design and realization of a multi‐coil array for B0 field control in a compact 1.5T head‐only MRI scanner

    by Sebastian Theilenberg, Yun Shang, Jalal Ghazouani, Chathura Kumaragamage, Terence W. Nixon, Scott McIntyre, J. Thomas Vaughan, Ben Parkinson, Mike Garwood, Robin A. de Graaf, et al.

    Purpose: To design and implement a multi-coil (MC) array for B-0 field generation for image encoding and simultaneous advanced shimming in a novel 1.5T head-only MRI scanner. Methods: A 31-channel MC array was designed following the unique constraints of this scanner design: The vertically oriented magnet is very short, stopping shortly above the shoulders of a sitting subject, and includes a window for the subject to see through. Key characteristics of the MC hardware, the B-0 field generation capabilities, and thermal behavior, were optimized in simulations prior to its construction. The unit was characterized via bench testing. B-0 field generation capabilitieswere validated on a human 4TMRscanner by analysis of experimental B-0 fields and by comparing images for severalMRI sequences acquired with theMC array to those acquired with the system's linear gradients. Results: The MC system was designed to produce a multitude of linear and nonlinear magnetic fields including linear gradients of up to 10 kHz/cm (23.5 mT/m) with MC currents of 5 A per channel. With water cooling it can be driven with a duty cycle of up to 74% and ramp times of 500 mu s. MR imaging experiments encoded with the developed multi-coil hardware were largely artifact-free; residual imperfections were predictable, and correctable. Conclusion: The presented compact multi-coil array is capable of generating image encoding fields with amplitudes and quality comparable to clinical systems at very high duty cycles, while additionally enabling high-order B-0 shimming capabilities and the potential for nonlinear encoding fields.


  • High‐resolution simulation of B0 field conditions in the human heart from segmented computed tomography images

    by Yun Shang, Sebastian Theilenberg, Maxim Terekhov, Wolfram Mattar, Boyu Peng, Sachin R. Jambawalikar, Laura M. Schreiber, Christoph Juchem

    B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady‐state free precession pulse sequences. The limited spatial resolution of MR‐derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI‐based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject‐ and population‐specific B0 shim strategies for the human heart.