CSCaroliny Hellen Silva

Caroliny Hellen Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Caroliny Hellen Silva has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of minimal cognitive behavioral therapy for patients with acute insomnia: A systematic review and meta-analysis

    by Douglas Barroso, Larissa Hespanhol, Maria Luísa Siegloch, Pedro Romeiro, Caroliny Silva, Isabela Costa, Alicja Garbacka, Alvaro Vitor Teixeira Filho, Daniel B. Kay


  • Open Access

    Impact of artificial intelligence on the training of general surgeons of the future: a scoping review of the advances and challenges

    by Caroliny Silva, Daniel Nascimento, Gabriela Gomes Dantas, Karoline Fonseca, Larissa Hespanhol, Amália Rego, Irami Araújo-Filho

    To explore artificial intelligence’s impact on surgical education, highlighting its advantages and challenges.


  • Open Access

    Direct Oral Anticoagulants versus Vitamin K Antagonists for Left Ventricular Thrombus: A Meta-Analysis with Trial Sequential Analysis

    by Eric Pasqualotto, Douglas Mesadri Gewehr, Rafael Oliva Morgado Ferreira, Matheus Pedrotti Chavez, Caroliny Hellen Silva, Sara Almeida Cruz, Jhonny Limachi-Choque, Amanda Park, Mário Sérgio Soares de Azeredo Coutinho, Luiz Fernando Kubrusly

    Background Vitamin K antagonists (VKAs) are the recommended first-line treatment for left ventricular thrombus (LVT); however, direct oral anticoagulants (DOACs) have been considered an alternative therapy. Objectives To evaluate the efficacy and safety of DOACs compared with VKAs therapy in patients with LVT. Methods PubMed, Embase, and Cochrane were systematically searched for randomized clinical trials or cohort studies that compared DOACs versus VKAs for LVT. Risk ratios (RRs) were computed for binary endpoints, with 95% confidence intervals (95% CIs). Statistical significance was defined as p value < 0.05. Results A total of 4 randomized clinical trials and 29 cohort studies were included, with 4,450 patients assigned to either DOACs or VKAs. There was no significant difference between groups for stroke or systemic embolic (SSE) events (RR 0.84; 95% CI 0.65 to 1.07; p = 0.157), stroke (RR 0.73; 95% CI 0.48 to 1.11; p = 0.140), systemic embolic (SE) events (RR 0.69; 95% CI 0.40 to 1.17; p = 0.166), thrombus resolution (RR 1.05; 95% CI 0.99 to 1.11; p = 0.077), any bleeding (RR 0.78; 95% CI 0.60 to 1.00; p = 0.054), clinically relevant bleeding (RR 0.69; 95% CI 0.46 to 1.03; p = 0.066), minor bleeding (RR 0.73; 95% CI 0.43 to 1.23; p = 0.234), major bleeding (RR 0.87; 95% CI 0.42 to 1.80; p = 0.705), and all-cause mortality (RR 1.05; 95% CI 0.79 to 1.39; p = 0.752). Compared with VKAs, rivaroxaban significantly reduced SSE events (RR 0.35; 95% CI 0.16 to 0.91; p = 0.029) and SE events (RR 0.39; 95% CI 0.16 to 0.95; p = 0.037). Conclusions DOACs had a similar rate of thromboembolic and hemorrhagic events, as well as thrombus resolution, compared to VKAs in the treatment of LVTs. Rivaroxaban therapy had a significant reduction in thromboembolic events, compared to VKAs.


  • Open Access

    Anticoagulantes Orais Diretos versus Antagonistas da Vitamina K para Trombo Ventricular Esquerdo: Uma Metanálise com Análise Sequencial de Ensaios

    by Eric Pasqualotto, Douglas Mesadri Gewehr, Rafael Oliva Morgado Ferreira, Matheus Pedrotti Chavez, Caroliny Hellen Silva, Sara Almeida Cruz, Jhonny Limachi-Choque, Amanda Park, Mário Sérgio Soares de Azeredo Coutinho, Luiz Fernando Kubrusly

    Resumo Fundamento Os antagonistas da vitamina K (AVKs) são o tratamento de primeira linha recomendado para trombo ventricular esquerdo (TVE); entretanto, os anticoagulantes orais diretos (AODs) têm sido considerados uma terapia alternativa. Objetivos Avaliar a eficácia e a segurança dos AODs em comparação com a terapia com AVKs em pacientes com TVE. Métodos PubMed, Embase e Cochrane foram sistematicamente pesquisados em busca de ensaios clínicos randomizados ou estudos de coorte que comparassem AODs versus AVKs para TVE. As razões de risco (RR) foram calculadas para desfechos binários, com intervalos de confiança (IC) de 95%. A significância estatística foi definida como valor de p < 0,05. Resultados Foram incluídos um total de 4 ensaios clínicos randomizados e 29 estudos de coorte, com 4.450 pacientes designados para AODs ou AVKs. Não houve diferença significativa entre os grupos para acidente vascular cerebral ou eventos embólicos sistêmicos (AVC/EES) (RR 0,84; IC 95% 0,65 a 1,07; p = 0,157), acidente vascular cerebral (RR 0,73; IC 95% 0,48 a 1,11; p = 0,140), eventos embólicos sistêmicos (EES) (RR 0,69; IC 95% 0,40 a 1,17; p = 0,166), resolução do trombo (RR 1,05; IC 95% 0,99 a 1,11; p = 0,077), qualquer sangramento (RR 0,78; IC 95% 0,60 a 1,00; p = 0,054), sangramento clinicamente relevante (RR 0,69; IC 95% 0,46 a 1,03; p = 0,066), sangramento menor (RR 0,73; IC 95% 0,43 a 1,23; p = 0,234), sangramento maior (RR 0,87; IC 95% 0,42 a 1,80; p = 0,705) e mortalidade por todas as causas (RR 1,05; IC 95% 0,79 a 1,39; p = 0,752). Em comparação com AVKs, a rivaroxabana reduziu significativamente AVC/EES (RR 0,35; IC 95% 0,16 a 0,91; p = 0,029) e EES (RR 0,39; IC 95% 0,16 a 0,95; p = 0,037). Conclusões Os AODs tiveram uma taxa semelhante de eventos tromboembólicos e hemorrágicos, bem como de resolução do trombo, em comparação com os AVKs no tratamento de TVE. A terapia com rivaroxabana teve uma redução significativa nos eventos tromboembólicos, em comparação com os AVKs.


  • Open Access

    Glucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials

    by Amanda Godoi, Isabela Reis Marques, Eduardo M. H. Padrão, Ashwin Mahesh, Larissa C. Hespanhol, José Eduardo Riceto Loyola Júnior, Isabela A. F. de Souza, Vittoria C. S. Moreira, Caroliny H. Silva, Isabele A. Miyawaki, et al.

    Background: Glycaemic control of Type 1 Diabetes Mellitus (T1DM) remains a challenge due to hypoglycaemic episodes and the burden of insulin self-management. Advancements have been made with the development of automated insulin delivery (AID) devices, yet, previous reviews have only assessed the use of AID over days or weeks, and potential benefits with longer time of AID use in this population remain unclear. Methods: We performed a systematic review and meta-analysis of randomised controlled trials comparing AID (hybrid and fully closed-loop systems) to usual care (sensor augmented pumps, multiple daily insulin injections, continuous glucose monitoring and predictive low-glucose suspend) for adults and children with T1DM with a minimum duration of 3 months. We searched PubMed, Embase, Cochrane Central, and Clinicaltrials.gov for studies published up until April 4, 2023. Main outcomes included time in range 70–180 mg/dL as the primary outcome, and change in HbA1c (%, mmol/mol), glucose variability, and psychosocial impact (diabetes distress, treatment satisfaction and fear of hypoglycaemia) as secondary outcomes. Adverse events included diabetic ketoacidosis (DKA) and severe hypoglycaemia. Statistical analyses were conducted using mean differences and odds ratios. Sensitivity analyses were performed according to age, study duration and type of AID device. The protocol was registered in PROSPERO, CRD42022366710. Results: We identified 25 comparisons from 22 studies (six crossover and 16 parallel designs) including a total of 2376 participants (721 in adult studies, 621 in paediatric studies, and 1034 in combined studies) which were eligible for analysis. Use of AID devices ranged from 12 to 96 weeks. Patients using AID had 10.87% higher time in range [95% CI 9.38 to 12.37; p < 0.0001, I2 = 87%) and 0.37% (4.77 mmol/mol) lower HbA1c (95% CI − 0.49% (− 6.39 mmol/mol) to – 0.26 (− 3.14 mmol/mol); p < 0·0001, I2 = 77%]. AID systems decreased night hypoglycaemia, time in hypoglycaemia and hyperglycaemia and improved patient distress, with no increase in the risk of DKA or severe hypoglycaemia. No difference was found regarding treatment satisfaction or fear of hypoglycaemia. Among children, there was no difference in glucose variability or time spent in hypoglycaemia between the use of AID systems or usual care. In sensitivity analyses, results remained consistent with the overall analysis favouring AID. Conclusion: The use of AID systems over 12 weeks, regardless of technical or clinical differences, improved glycaemic outcomes and diabetes distress without increasing the risk of adverse events in adults and children with T1DM.


  • The Single-Syringe Versus the Double-Syringe Techniques of Adenosine Administration for Supraventricular Tachycardia: A Systematic Review and Meta-Analysis

    by Isabele A. Miyawaki, Cintia Gomes, Vittoria Caporal S. Moreira, Isabela R. Marques, Isabela A. F. de Souza, Caroliny H. A. Silva, José Eduardo Riceto Loyola Júnior, Kangwook Huh, Marc McDowell, Eduardo M. H. Padrao, et al.

    Introduction The intravenous double-syringe technique (DST) of adenosine administration is the first-line treatment for stable supraventricular tachycardia (SVT). Alternatively, the single-syringe technique (SST) was recently found to be potentially beneficial in several studies. This study aimed to perform a meta-analysis of the SST versus the DST of adenosine administration for the treatment of SVT. Methods We assessed EMBASE, PubMed, Cochrane, and ClinicalTrials.gov databases for randomized controlled trials (RCTs) and non-randomized studies of intervention (NRSIs) comparing the DST to the SST of adenosine administration in patients with SVT. Outcomes included termination rate, termination rate at first dose, total administered dose, adverse effects, and discharge rate. Results We included four studies (three RCTs and one NRSI) with a total of 178 patients, of whom 99 underwent the SST of adenosine administration. No significant difference was found between treatment groups regarding termination rate, termination rate restricted to RCTs, total administered dose, and discharge rate. Termination rate at first dose (odds ratio 2.87; confidence interval 1.11–7.41; p = 0.03; I2 = 0%) was significantly increased in patients who received the SST. Major adverse effects were observed in only one study. Conclusions The SST is probably as safe as the DST and at least as effective for SVT termination, SVT termination at first dose, and discharge rate from the emergency department. However, definitive superiority of one technique is not feasible given the limited sample size. Registration PROSPERO identifier nº CRD42022345125.