Muhammet Anıl Kaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammet Anıl Kaya has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cengiz Görkem Dengiz
Ondokuz Mayıs University
2 shared publications - Erkan Öztürk
Ondokuz Mayis Üniversitesi
1 shared publication - Kemal Yıldızlı
Ondokuz Mayıs University
1 shared publication - Kenan Büyükkaya
GİRESUN ÜNİVERSİTESİ, TEKNİK BİLİMLER MESLEK YÜKSEKOKULU
1 shared publication - Murat Aydin
Karadeniz Technical University
1 shared publication
Latest Publications
- 11 December 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 240 (11) , 1864-1877
Effect of plasma nitriding on pistol slides
This study investigates the effects of traditional quenching and plasma (ion) nitriding on the microstructure and mechanical properties of cold-drawn low-alloy AISI 4140 steel, which is widely utilised in the light weapons and defence industries. AISI 4140 alloy is widely used in pistol slides in the small arms industry. The quenching method enhances the strength of pistol slides, which endure high loads during firing. However, the distortions and restrictions encountered during this process affect the strength of the slides. In this study, cold-drawn AISI 4140 material was subjected to plasma nitriding, a thermochemical process increasingly used in the defense industry, and various properties were compared with the traditional quenching process. The structural and mechanical properties of the alloy were analyzed in the raw material (cold-drawn, untreated), quenched-tempering (QT) and quenched-tempering-plasma nitriding (QT + plasma nitrided) conditions, focusing especially on fatigue performance. The results revealed that the raw material consists of deformation-induced grain-oriented ferrite and pearlite phases. The QT process transformed the microstructure predominantly into bainite and martensite. QT + plasma nitrided resulted in chemical modifications at the surface, forming a white layer containing iron nitrides and a diffusion layer containing alloy nitrides. The effective hardening depth due to nitrogen diffusion was measured as 0.25–0.30 mm. The QT + plasma-nitrided specimen showed the highest hardness, tensile strength, impact toughness, and better fatigue performance. In particular, fatigue cracks initiated from the surface in the raw material and QT specimens. In contrast, fisheye cracks between the diffusion layer and the core in the QT + plasma-nitrided specimens indicated an improved fatigue-resistance mechanism. These findings highlight the advantages of plasma nitriding as an advanced surface-hardening technique for improving the dimensional stability and performance of critical components, especially in the small-arms industry.
- 11 December 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 240 (11) , 1864-1877
Effect of plasma nitriding on pistol slides
This study investigates the effects of traditional quenching and plasma (ion) nitriding on the microstructure and mechanical properties of cold-drawn low-alloy AISI 4140 steel, which is widely utilised in the light weapons and defence industries. AISI 4140 alloy is widely used in pistol slides in the small arms industry. The quenching method enhances the strength of pistol slides, which endure high loads during firing. However, the distortions and restrictions encountered during this process affect the strength of the slides. In this study, cold-drawn AISI 4140 material was subjected to plasma nitriding, a thermochemical process increasingly used in the defense industry, and various properties were compared with the traditional quenching process. The structural and mechanical properties of the alloy were analyzed in the raw material (cold-drawn, untreated), quenched-tempering (QT) and quenched-tempering-plasma nitriding (QT + plasma nitrided) conditions, focusing especially on fatigue performance. The results revealed that the raw material consists of deformation-induced grain-oriented ferrite and pearlite phases. The QT process transformed the microstructure predominantly into bainite and martensite. QT + plasma nitrided resulted in chemical modifications at the surface, forming a white layer containing iron nitrides and a diffusion layer containing alloy nitrides. The effective hardening depth due to nitrogen diffusion was measured as 0.25–0.30 mm. The QT + plasma-nitrided specimen showed the highest hardness, tensile strength, impact toughness, and better fatigue performance. In particular, fatigue cracks initiated from the surface in the raw material and QT specimens. In contrast, fisheye cracks between the diffusion layer and the core in the QT + plasma-nitrided specimens indicated an improved fatigue-resistance mechanism. These findings highlight the advantages of plasma nitriding as an advanced surface-hardening technique for improving the dimensional stability and performance of critical components, especially in the small-arms industry.
- 13 August 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (3) , 3621-3648
The Development of a Mechanical Friction Measurement Approach to Employ a Novel Designed and Manufactured Pantograph Tribometer
- 13 August 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (3) , 3621-3648
The Development of a Mechanical Friction Measurement Approach to Employ a Novel Designed and Manufactured Pantograph Tribometer
- Open Access
- 15 June 2022
- Published by Karadeniz Fen Bilimleri Dergisi in Karadeniz Fen Bilimleri Dergisi
- Vol. 12 (1) , 340-354
Investigation of Static Strain Aging Behaviour of AISI 304 Austenitic Stainless Steel
In this study, the change in the material's mechanical properties by the static strain ageing process after the pre-deformation applied to AISI 304 austenitic stainless steel was investigated and analysed. The samples were first applied to 5% pre-deformation and then annealed in the oven at 150°C, 250°C, 400°C and 550°C in separate groups for 30 and 60 minutes. The data obtained by performing hardness and tensile tests after static strain ageing were compared, and the interaction between test parameters and these parameters was investigated by performing Pareto analysis. As a result of the study, the highest tensile strength and hardness values were observed in the samples applied static strain ageing for 60 minutes at 150°C. The yield and tensile strengths of the as-received material increased by 10% with the ageing process. It was determined that these values decreased from 400°C. In addition, as a result of Pareto analysis, it was determined that the temperature value is the most critical parameter affecting the results.
- 15 June 2022
- Published by Karadeniz Fen Bilimleri Dergisi in Karadeniz Fen Bilimleri Dergisi
- Vol. 12 (1) , 340-354
Open AccessInvestigation of Static Strain Aging Behaviour of AISI 304 Austenitic Stainless Steel
In this study, the change in the material's mechanical properties by the static strain ageing process after the pre-deformation applied to AISI 304 austenitic stainless steel was investigated and analysed. The samples were first applied to 5% pre-deformation and then annealed in the oven at 150°C, 250°C, 400°C and 550°C in separate groups for 30 and 60 minutes. The data obtained by performing hardness and tensile tests after static strain ageing were compared, and the interaction between test parameters and these parameters was investigated by performing Pareto analysis. As a result of the study, the highest tensile strength and hardness values were observed in the samples applied static strain ageing for 60 minutes at 150°C. The yield and tensile strengths of the as-received material increased by 10% with the ageing process. It was determined that these values decreased from 400°C. In addition, as a result of Pareto analysis, it was determined that the temperature value is the most critical parameter affecting the results.