Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arda Zaim has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dynamic Field Assessment of Pressure Drop and Pressure Dew Point Performance in an Industrial Refrigerated Compressed Air Dryer Line

    by Arda Zaim

    Compressed air is one of the primary energy carriers used to operate pneumatic equipment and industrial processes. Moisture control is important for achieving the required air quality at the point of use. Refrigerated dryers reduce the moisture content of compressed air by condensing water vapor. Industrial field studies that jointly examine the hydraulic behavior and pressure dew point performance of refrigerated dryer lines under variable production demand remain limited. This study evaluated the hydraulic and pressure dew point performance of an industrial refrigerated dryer line under actual production conditions. Volumetric flow rate, line pressure, line pressure drop, and outlet pressure dew point were measured simultaneously. The flow rate ranged from 8.37 to 23.59 m³ min⁻¹. Line pressure drop ranged from 0.081 to 0.665 bar. The ratio of pressure drop to inlet pressure reached a maximum of 10.48%. The slope of the relationship between flow rate and pressure drop increased at higher flow rates. After initial conditioning, the outlet pressure dew point remained below the +3 °Ctd limit defined for water in ISO 8573-1. Short term changes in flow rate and pressure drop were not reflected in the outlet pressure dew point on the same time scale. This study provides field data at the system level for the simultaneous assessment of pressure dew point performance and hydraulic behavior under variable production demand.

  • Experimental assessment of energy consumption and CO 2 impacts of compressed air leakage across industrial sectors

    by Arda Zaim, Cisil Timuralp, Haydar Aras

    This study evaluates energy consumption resulting from compressed air leakage and the associated CO 2 equivalent emissions in industrial pneumatic systems. The analysis is based on ultrasonic field measurements conducted in 10 industrial facilities in Turkey. Measurements were performed under normal production conditions. Detected leakage points were classified by equipment category and measured flow rate range. Annual energy losses were calculated using a common SEC reference. The corresponding emission values were calculated using the national electricity emission factor. Leakage ratios ranged from 7% to 33% across the investigated facilities. Facilities with similar system scale showed different leakage ratios. Annual leakage-related energy losses ranged from 26.3 to 271.8 MWh per year. Normalized hourly losses ranged from 4 to 38 kWh/h. The calculated emission values ranged from 10 to 120 tCO 2 per year. Fittings and tubing showed the highest leakage contribution among equipment categories in the measured dataset. Connection sealing was the second major source group. Flow rate range classification separated leakage presence from leakage impact within equipment categories. The findings connect leakage location and measured flow rate with energy loss and calculated emission values in industrial compressed air systems.

  • Open Access

    Software-Based Automation and Control Architecture for a Magnetic Refrigeration System

    by Arda Zaim, Haydar Aras

    In this study, software-based, measurement-driven automation and control architecture is developed for magnetic refrigeration systems. The proposed structure integrates real-time measurement data obtained from magnetic, hydraulic, and thermal sub-processes within a single decision layer. Control actions are generated based on cycle-level performance feedback. Instead of directly regulating absolute performance values, the control logic relies on performance trends between successive cycles as the primary decision variable. The method is experimentally implemented on a reciprocating magnetic refrigerator prototype. The system is first operated with fixed parameters, after which cycle-level adaptation is activated using measurement-based decisions. Experimental results show that adaptive control drives the system toward a stable and high-performance regime following a short transient phase. The average coefficient of performance (COP) increases from approximately 0.21 under manual operation to about 1.20 in adaptive operation, while cycle-to-cycle fluctuations are significantly reduced. The results indicate that operation based on fixed timing and preset parameters is insufficient for magnetic refrigeration systems. In contrast, software-based control using cyclic feedback shifts the system to a more stable and efficient regime. The proposed architecture provides a high-level control framework with low hardware dependency and can be adapted to different magnetic refrigeration configurations.


  • Open Access

    Industrial Compressed Air System Optimization: Experimental Evaluation of Energy Efficiency and Sustainability Gains

    by Arda Zaim

    This study presents an experimental optimization of an industrial-scale compressed air system aimed at improving energy efficiency and operational performance. The evaluation was conducted in accordance with ISO 11011 standards, covering supply, distribution, demand, and air quality aspects. Reference and optimized scenarios were directly compared under equivalent operating conditions. The most significant improvement was the elimination of a 0.54-bar pressure drop, which enabled the compressor’s set pressure to be reduced from 7.0 bar to 6.5 bar and prevented unnecessary load cycles. In addition, the detection and repair of leakage points significantly reduced constant loads during non-production hours. As a result, average power consumption decreased by 32.6%, while idle consumption was reduced by 70%. Improvements in filtration and condensate management lowered moisture and oil carryover, thereby enhancing process reliability. Considering annual operating hours, the optimization was estimated to offer a potential reduction of approximately 63.5 tons of CO2 emissions. The results demonstrate that substantial efficiency and sustainability gains can be achieved through physical adjustments and operational measures without modifying control algorithms.


  • Open Access

    Gd ve La0.75Ba0.25MnO3 BİLEŞİĞİNİN YAPISAL ÖZELLİKLERİNİN VE MANYETİK SOĞUTMA PERFORMANSLARININ DENEYSEL OLARAK ARAŞTIRILMASI

    by Arda Zaim, Haydar Aras, Cumhur Gökhan Ünlü

    Çalışmada oda sıcaklığına yakın sıcaklıklarda çalışan manyetik soğutma sistemlerinde manyetokalorik malzeme olarak kullanılan Gd elementinin ve La0.75Ba0.25MnO3 perovskit manganit bileşiğinin yapısal özellikleri ve manyetik soğutma performansı deneysel olarak incelenmiştir. La0.75Ba0.25MnO3 perovskit manganit bileşiği sol-jel yöntemiyle sentezlenmiş, her iki manyetokalorik malzemenin yapısal özellikleri SEM ve EDX analizi gerçekleştirilerek detaylı bir şekilde ele alınmıştır. SEM analizinde Gd elementi için tane boyutlarının homojen bir dağılıma sahip olmadığı, tane boyutlarının 2-20 µm aralığında değiştiği ve kübik benzeri formda sert köşeli bir yapıda olduğu belirlenmiş olup; La0.75Ba0.25MnO3 perovskit manganit bileşiğinde ise daha küçük tane boyutlu, küresel geometride, süngerimsi yapıda, homojen dağılımlı ve düşük boşluklu bir yapı gözlenmiştir. EDX analizinde Gd elementinde yapının tamamen Gd’den oluştuğu, sol-jel yöntemiyle sentezlenen perovskit manganit bileşiğinde istenilen yapı karakterizasyonunun elde edildiği tespit edilmiştir. 1.2 T manyetik akı yoğunluğunda gerçekleştirilen zamana bağlı sıcaklık değişimi deneylerinde 250 çevrim sonrasında kritik kullanım faktörü olarak tanımlanan φ=15’de; Gd elementinde 2.204 K, La0.75Ba0.25MnO3 perovskit manganit bileşiğinde ise 1.472 K sıcaklık farkı elde edilmiştir.

  • Pnömatik Sistemlerde Enerji Verimliliği

    by Arda Zai̇m, Haydar Aras

    Artan nüfus ve gelişen teknolojiyle birlikte enerji tüketimi ve maliyetleri günden güne artış göstermektedir. Ülkemiz fosil enerji kaynakları bakımından sınırlı kaynaklara sahip ve dışa bağımlıdır. Enerji ihtiyacının güvenilir, ekonomik ve yeterli bir biçimde karşılanabilmesi temel amaçtır. Bu bağlamda enerjinin verimli kullanımı üzerinde önemle durulması gereken hususlar arasında yer almaktadır. Enerji verimliliği, harcanan enerji miktarının, üretimdeki kapasite ve kaliteyi azaltmadan, ekonomik kalkınmayı ve sosyal refahı engellemeden en aza indirilmesidir. Bu çalışmada, endüstride en çok kullanılan ikincil enerji kaynağı basınçlı havayla çalışan pnömatik sistemlerdeki enerji verimliliği uygulamaları ele alınmış ve deneysel çalışmalarla desteklenmiştir. Basınçlı hava sistemi tasarımında verimliliği artıran unsurlar belirlenmiş; kompresör, silindir ve vakum ejektörü gibi pnömatik iş elemanlarında işletme basınçlarının düşürülmesiyle elde edilebilecek tasarruf miktarları hesaplanmıştır. Ciddi maliyetler oluşturan hava kaçaklarının tespiti ve maliyeti konusunda fiziki bulgular incelenmiş, enerji tasarruf fonksiyonlu ürünlerin kullanımı için yol gösterilmiştir. Çalışmanın, enerji arzında büyük oranda dışa bağımlı olan ülkemizin sanayi sektöründe enerji yoğunluğunun düşürülmesi ve karbon ayak izinin azaltılması faaliyetlerinde bir rehber niteliği taşıyacağı düşünülmektedir.