    Association between elastotonometric rise and bidirectional pneumatic applanation in the assessment of intraocular pressure after refractive surgery

    by А. A. Antonov, Е. А. Klinicheva, A. V. Volzhanin, А. S. Avagyan, Т. М. Aghajanyan, D. A. Dorofeev, А. А. Антонов, Е. А. Клиничева, А. В. Волжанин, А. С. Авагян, et al.

    INTRODUCTION . Correction of myopia and myopic astigmatism with LASIK, FS-LASIK, and photorefractive keratectomy (PRK) affects the biomechanical properties of the cornea, leading to distorted applanation tonometry readings. Filatov–Kalfa elastotonometry and bidirectional pneumatic applanation using the Ocular Response Analyzer (ORA) assess different components of the biomechanical response, and correlations between these methods after corneal refractive surgery remain insufficiently studied. P URPOSE . To evaluate how Filatov–Kalfa elastotonometry findings reflect corneal biomechanical properties measured with ORA in patients after corneal refractive correction of myopia and myopic astigmatism. METHODS . The study included 61 patients (121 eyes): the control group consisted of 31 eyes without a history of corneal refractive surgery, and the study group comprised 90 eyes divided into three subgroups after LASIK, FS-LASIK, and PRK. Elastotonometry was performed using 5, 7.5, and 15 g weights, along with Maklakov tonometry (10 g), noncontact pneumotonometry (NCT), and ORA assessment with measurement of corneal-compensated intraocular pressure (IOPcc), Goldmann-correlated intraocular pressure (IOPg), corneal hysteresis (CH), corneal resistance factor (CRF), and the biomechanical stress coefficient (Kbs). ΔIOP7.5/5 (corneal component), ΔIOP10/5 (corneoscleral component), ΔIOP15/10 (scleral component), and ΔIOP15/5 were calculated; Spearman correlation analysis was performed (p < 0.05). RESULTS . In the control group, significant correlations of ORA parameters, except Kbs, were found only with the corneal component (ΔIOP7.5/5). After LASIK, most IOP and biomechanical parameters, including IOPg, CH, CRF, and NCT, showed moderate correlations with the total elastotonometric rise ΔIOP15/5. In the FS-LASIK group, the main ORA and pneumotonometry parameters showed the strongest associations with the corneoscleral component ΔIOP10/5. After PRK, IOPcc, IOPg, CH, CRF, and Kbs were most strongly associated with the scleral and total components (ΔIOP15/10 and ΔIOP15/5). CONCLUSION . Correlations between Filatov–Kalfa elastotonometry results and ORA measurements differ substantially after LASIK, FS-LASIK, and PRK, reflecting the procedure-specific effects of these techniques on corneal biomechanical properties. Accounting for the dominant component of elastotonometric IOP rise may improve the accuracy of tonometry and assessment of the biomechanical status of the eye in the postoperative period.

  • Relationship between Maklakov tonometry and pneumatic applanation tonometry readings after refractive surgery

    by A. A. Antonov, E. A. Klinicheva, A. V. Volzhanin, T. M. Aghajanyan

    PURPOSE. This study examined the relationship between Maklakov tonometry readings obtained using weights of different masses and biomechanically corrected intraocular pressure (IOP) values measured by pneumatic applanation tonometry in patients after various types of keratorefractive surgery (LASIK, FS-LASIK, and PRK). METHODS. The study included 61 patients (121 eyes): a control group (n=31) and three postoperative groups – LASIK (n=26), FS-LASIK (n=32), and PRK (n=32). All patients underwent Maklakov tonometry using 5-, 10-, and 15-g weights. Using the Ocular Response Analyzer (ORA), corneal-compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), corneal hysteresis (CH), corneal resistance factor (CRF), and the biomechanical stress coefficient (Kbs) were measured. RESULTS. The strongest inverse correlations between Maklakov tonometry and IOPcc were observed in the PRK group (r=−0.80 and r=−0.91 for the 5- and 10-g weights, respectively), whereas in the LASIK group the maximum association was found with the 5-g weight (r=−0.85), weakening as the weight mass increased. In the FS-LASIK group, significant correlations were predominantly observed with the 10-g weight (r=−0.67). In the control group, the 10-g weight showed no correlation with any parameter, while the 5- and 15-g weights demonstrated moderate correlations with IOPcc, IOPg, CRF, and Kbs. Corneal hysteresis correlated significantly only with the 5-g weight in the PRK group (r=−0.491). CONCLUSION. After LASIK and PRK, Maklakov tonometry using a 5-g weight compares the best with biomechanically corrected IOP values, whereas after FS-LASIK the 10-g weight appears to be preferable. These findings underscore the need for individualized selection of weight mass when performing Maklakov tonometry in patients with altered corneal biomechanics.

  • Open Access

    Efficacy and safety of 0.1 % brimonidine as a starting monotherapy and when added to combination therapy of glaucoma

    by E. D. Semenov, A. A. Antonov, Kh. Hadiri, T. M. Aghajanyan, Х. Хдери

    Purpose: to analyze the efficacy and safety of Santabrim® as a starting monotherapy and when added to combination therapy for glaucoma.Material and methods. The study was conducted on 60 patients (60 eyes), including 21 (35 %) men and 39 (65 %) women, with initial or advanced primary open-angle glaucoma with moderately elevated IOP. The average age of patients was 63.4 years. The first group (30 eyes) consisted of patients who were prescribed Santabrim® 2 times a day as a starting monotherapy. The second group consisted of patients (30 eyes) who had an enhanced regimen using Santabrim® 2 times a day as a third drug. To analyze the hypotensive effect, the data of corneally compensated IOP were compared at the first visit and 1 month after the appointment or enhancement of the local hypotensive regimen. Safety was assessed by comparing the degree of fluorescein staining of the cornea, conjunctival hyperemia, OSDI questionnaire indicators and the level of adherence to treatment at the appropriate time in two groups of patients.Results. Santabrim® significantly reduces the level of IOP. The use of the drug as monotherapy allows to reduce IOP by 26.3 % of the initial level. Strengthening combination therapy by adding Santabrem® as a third drug allows reducing the level of IOP by an additional 15.9 %. Objective indicators of the condition of the tissues of the anterior surface of the eye have not changed significantly. Based on the results of the assessment of the main signs of dry eye syndrome (OSDI) and the degree of patient adherence to treatment, no significant changes were revealed.Conclusion. Brimonidine 0.1 % (Santabrim®) can be recommended for the hypotensive treatment of glaucoma both in monotherapy and in combination with other groups of local instillation drugs, and its direct neuroprotective effect additionally contributes to the stabilization of glaucoma opticoneuropathy.

  • Open Access

    The choice of IOP measurement method for assessing the effectiveness of glaucoma surgery

    by A. A. Vitkov, Kh. Hadiri, T. M. Aghajanyan, A. M. Akimov, I. I. Asinovskova, A. A. Komarov, E. D. Semenov, Х. Хдери

    Purpose of this study — to compare the results of different tonometry methods before surgical treatment of glaucoma and in the early postoperative period.The study was conducted on a group of 50 patients (50 eyes) aged 55 to 80 years with uncompensated primary open-angle glaucoma, who were admitted to in-patient department for glaucoma surgery. Patients were examined using bidirectional applanation tonometry of the cornea performed on Ocular Response Analyzer, pneumotonometry on Canon TX-20P device, and with Icare tonometer. These studies were carried out on the day before the surgery, the next day, and 2 weeks after the operation.Significant differences in tonometry readings were revealed between all tested devices at high intraocular pressure (IOP) levels (before glaucoma surgery). Significant differences were also found in IOP values obtained with Icare tonometer in the central zone of the cornea and in the middle periphery in the nasal and temporal sectors. A significant difference between the indicators remained on the next day after surgery, except for the Icare readings. After two weeks, the tonometric parameters did not differ significantly from each other.Corneal compensated IOP (IOPcc) is the most important tonometric indicator in clinical practice because it takes into account the individual biomechanical characteristics of the patient’s cornea. When examining patients with glaucoma, the IOPcc indicator significantly differed in uncompensated IOP, which is important for determining the correct treatment tactics. When assessing the level of IOP after surgery this trend persisted, indicating a systematic underestimation of IOP level (overestimation of the effect of glaucoma surgery). The reliability of the study is confirmed by the results of measurements on unoperated fellow eyes (control).