Jonghwan Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonghwan Shin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Sukhan Lee
Department of AI & Robotics, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
2 shared publications - Juneho Yi
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication - Ranjita Kumari
Electrical and Computer Engineering Department, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication - Soojin Lee
Department of Artificial Intelligence, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Effect of Perceptual Training with Sound-Guided and Kinesthetic Feedback on Human 3D Sound Localization Capabilities
In this paper, we experimentally investigate how the 3D sound localization capabilities of the blind can improve through perceptual training. To this end, we develop a novel perceptual training method with sound-guided feedback and kinesthetic assistance to evaluate its effectiveness compared to conventional training methods. In perceptual training, we exclude visual perception by blindfolding the subjects to apply the proposed method to the visually impaired. Subjects used a specially designed pointing stick to generate a sound at the tip, indicating localization error and tip position. The proposed perceptual training aims to evaluate the training effect on 3D sound localization, including variations in azimuth, elevation, and distance. The six days of training based on six subjects resulted in the following outcomes: (1) In general, accuracy in full 3D sound localization can be improved based on training. (2) Training based on relative error feedback is more effective than absolute error feedback. (3) Subjects tend to underestimate distance when the sound source is near, less than 1000 mm, or larger than 15° to the left, and overestimate the elevation when the sound source is near or in the center, and within ±15° in azimuth estimations.
Open AccessEffect of Perceptual Training with Sound-Guided and Kinesthetic Feedback on Human 3D Sound Localization Capabilities
In this paper, we experimentally investigate how the 3D sound localization capabilities of the blind can improve through perceptual training. To this end, we develop a novel perceptual training method with sound-guided feedback and kinesthetic assistance to evaluate its effectiveness compared to conventional training methods. In perceptual training, we exclude visual perception by blindfolding the subjects to apply the proposed method to the visually impaired. Subjects used a specially designed pointing stick to generate a sound at the tip, indicating localization error and tip position. The proposed perceptual training aims to evaluate the training effect on 3D sound localization, including variations in azimuth, elevation, and distance. The six days of training based on six subjects resulted in the following outcomes: (1) In general, accuracy in full 3D sound localization can be improved based on training. (2) Training based on relative error feedback is more effective than absolute error feedback. (3) Subjects tend to underestimate distance when the sound source is near, less than 1000 mm, or larger than 15° to the left, and overestimate the elevation when the sound source is near or in the center, and within ±15° in azimuth estimations.
- Open Access
Real-Time Deep Recognition of Standardized Liver Ultrasound Scan Locations
Liver ultrasound (US) plays a critical role in diagnosing liver diseases. However, it is often difficult for examiners to accurately identify the liver segments captured in US images due to patient variability and the complexity of US images. Our study aim is automatic, real-time recognition of standardized US scans coordinated with reference liver segments to guide examiners. We propose a novel deep hierarchical architecture for classifying liver US images into 11 standardized US scans, which has yet to be properly established due to excessive variability and complexity. We address this problem based on a hierarchical classification of 11 US scans with different features applied to individual hierarchies as well as a novel feature space proximity analysis for handling ambiguous US images. Experiments were performed using US image datasets obtained from a hospital setting. To evaluate the performance under patient variability, we separated the training and testing datasets into distinct patient groups. The experimental results show that the proposed method achieved an F1-score of more than 93%, which is more than sufficient for a tool to guide examiners. The superior performance of the proposed hierarchical architecture was demonstrated by comparing its performance with that of non-hierarchical architecture.
Open AccessReal-Time Deep Recognition of Standardized Liver Ultrasound Scan Locations
Liver ultrasound (US) plays a critical role in diagnosing liver diseases. However, it is often difficult for examiners to accurately identify the liver segments captured in US images due to patient variability and the complexity of US images. Our study aim is automatic, real-time recognition of standardized US scans coordinated with reference liver segments to guide examiners. We propose a novel deep hierarchical architecture for classifying liver US images into 11 standardized US scans, which has yet to be properly established due to excessive variability and complexity. We address this problem based on a hierarchical classification of 11 US scans with different features applied to individual hierarchies as well as a novel feature space proximity analysis for handling ambiguous US images. Experiments were performed using US image datasets obtained from a hospital setting. To evaluate the performance under patient variability, we separated the training and testing datasets into distinct patient groups. The experimental results show that the proposed method achieved an F1-score of more than 93%, which is more than sufficient for a tool to guide examiners. The superior performance of the proposed hierarchical architecture was demonstrated by comparing its performance with that of non-hierarchical architecture.