Ranjita Kumari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ranjita Kumari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jitae Shin
Sungkyunkwan University
2 shared publications - Pradeep Kumar Anand
College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Korea
2 shared publications - Sukhan Lee
Department of AI & Robotics, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
2 shared publications - Jonghwan Shin
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication - Soojin Lee
Department of Artificial Intelligence, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 18 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (12) , 1558
Sound Localization Training and Induced Brain Plasticity: An fMRI Investigation
Background/Objectives: Neuroimaging techniques have been increasingly utilized to explore neuroplasticity induced by various training regimens. Magnetic resonance imaging (MRI) enables to study these changes non-invasively. While visual and motor training have been widely studied, less is known about how auditory training affects brain activity. Our objective was to investigate the effects of sound localization training on brain activity and identify brain regions exhibiting significant changes in activation pre- and post-training to understand how sound localization training induces plasticity in the brain. Method: Six blindfolded participants each underwent 30-minute sound localization training sessions twice a week for three weeks. All participants completed functional MRI (fMRI) testing before and after the training. Results: fMRI scans revealed that sound localization training led to increased activation in several cortical areas, including the superior frontal gyrus, superior temporal gyrus, middle temporal gyrus, parietal lobule, precentral gyrus, and postcentral gyrus. These regions are associated with cognitive processes such as auditory processing, spatial working memory, planning, decision-making, error detection, and motor control. Conversely, a decrease in activation was observed in the left middle temporal gyrus, a region linked to language comprehension and semantic memory. Conclusions: These findings suggest that sound localization training enhances neural activity in areas involved in higher-order cognitive functions, spatial attention, and motor execution, while potentially reducing reliance on regions involved in basic sensory processing. This study provides evidence of training-induced neuroplasticity, highlighting the brain’s capacity to adapt through targeted auditory training intervention.
- 18 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (12) , 1558
Open AccessSound Localization Training and Induced Brain Plasticity: An fMRI Investigation
Background/Objectives: Neuroimaging techniques have been increasingly utilized to explore neuroplasticity induced by various training regimens. Magnetic resonance imaging (MRI) enables to study these changes non-invasively. While visual and motor training have been widely studied, less is known about how auditory training affects brain activity. Our objective was to investigate the effects of sound localization training on brain activity and identify brain regions exhibiting significant changes in activation pre- and post-training to understand how sound localization training induces plasticity in the brain. Method: Six blindfolded participants each underwent 30-minute sound localization training sessions twice a week for three weeks. All participants completed functional MRI (fMRI) testing before and after the training. Results: fMRI scans revealed that sound localization training led to increased activation in several cortical areas, including the superior frontal gyrus, superior temporal gyrus, middle temporal gyrus, parietal lobule, precentral gyrus, and postcentral gyrus. These regions are associated with cognitive processes such as auditory processing, spatial working memory, planning, decision-making, error detection, and motor control. Conversely, a decrease in activation was observed in the left middle temporal gyrus, a region linked to language comprehension and semantic memory. Conclusions: These findings suggest that sound localization training enhances neural activity in areas involved in higher-order cognitive functions, spatial attention, and motor execution, while potentially reducing reliance on regions involved in basic sensory processing. This study provides evidence of training-induced neuroplasticity, highlighting the brain’s capacity to adapt through targeted auditory training intervention.
- Open Access
- 27 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2514
Improving the Accuracy of Continuous Blood Glucose Measurement Using Personalized Calibration and Machine Learning
Despite tremendous developments in continuous blood glucose measurement (CBGM) sensors, they are still not accurate for all patients with diabetes. As glucose concentration in the blood is <1% of the total blood volume, it is challenging to accurately measure glucose levels in the interstitial fluid using CBGM sensors due to within-patient and between-patient variations. To address this issue, we developed a novel data-driven approach to accurately predict CBGM values using personalized calibration and machine learning. First, we scientifically divided measured blood glucose into smaller groups, namely, hypoglycemia (250 mg/dL). Second, we separately trained each group using different machine learning models based on patients’ personalized parameters, such as physical activity, posture, heart rate, breath rate, skin temperature, and food intake. Lastly, we used multilayer perceptron (MLP) for the D1NAMO dataset (training to test ratio: 70:30) and grid search for hyperparameter optimization to predict accurate blood glucose concentrations. We successfully applied our proposed approach in nine patients with type 1 diabetes and observed that the mean absolute relative difference (MARD) decreased from 17.8% to 8.3%.
- 27 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2514
Open AccessImproving the Accuracy of Continuous Blood Glucose Measurement Using Personalized Calibration and Machine Learning
Despite tremendous developments in continuous blood glucose measurement (CBGM) sensors, they are still not accurate for all patients with diabetes. As glucose concentration in the blood is <1% of the total blood volume, it is challenging to accurately measure glucose levels in the interstitial fluid using CBGM sensors due to within-patient and between-patient variations. To address this issue, we developed a novel data-driven approach to accurately predict CBGM values using personalized calibration and machine learning. First, we scientifically divided measured blood glucose into smaller groups, namely, hypoglycemia (250 mg/dL). Second, we separately trained each group using different machine learning models based on patients’ personalized parameters, such as physical activity, posture, heart rate, breath rate, skin temperature, and food intake. Lastly, we used multilayer perceptron (MLP) for the D1NAMO dataset (training to test ratio: 70:30) and grid search for hyperparameter optimization to predict accurate blood glucose concentrations. We successfully applied our proposed approach in nine patients with type 1 diabetes and observed that the mean absolute relative difference (MARD) decreased from 17.8% to 8.3%.
- Open Access
Effect of Perceptual Training with Sound-Guided and Kinesthetic Feedback on Human 3D Sound Localization Capabilities
In this paper, we experimentally investigate how the 3D sound localization capabilities of the blind can improve through perceptual training. To this end, we develop a novel perceptual training method with sound-guided feedback and kinesthetic assistance to evaluate its effectiveness compared to conventional training methods. In perceptual training, we exclude visual perception by blindfolding the subjects to apply the proposed method to the visually impaired. Subjects used a specially designed pointing stick to generate a sound at the tip, indicating localization error and tip position. The proposed perceptual training aims to evaluate the training effect on 3D sound localization, including variations in azimuth, elevation, and distance. The six days of training based on six subjects resulted in the following outcomes: (1) In general, accuracy in full 3D sound localization can be improved based on training. (2) Training based on relative error feedback is more effective than absolute error feedback. (3) Subjects tend to underestimate distance when the sound source is near, less than 1000 mm, or larger than 15° to the left, and overestimate the elevation when the sound source is near or in the center, and within ±15° in azimuth estimations.
Open AccessEffect of Perceptual Training with Sound-Guided and Kinesthetic Feedback on Human 3D Sound Localization Capabilities
In this paper, we experimentally investigate how the 3D sound localization capabilities of the blind can improve through perceptual training. To this end, we develop a novel perceptual training method with sound-guided feedback and kinesthetic assistance to evaluate its effectiveness compared to conventional training methods. In perceptual training, we exclude visual perception by blindfolding the subjects to apply the proposed method to the visually impaired. Subjects used a specially designed pointing stick to generate a sound at the tip, indicating localization error and tip position. The proposed perceptual training aims to evaluate the training effect on 3D sound localization, including variations in azimuth, elevation, and distance. The six days of training based on six subjects resulted in the following outcomes: (1) In general, accuracy in full 3D sound localization can be improved based on training. (2) Training based on relative error feedback is more effective than absolute error feedback. (3) Subjects tend to underestimate distance when the sound source is near, less than 1000 mm, or larger than 15° to the left, and overestimate the elevation when the sound source is near or in the center, and within ±15° in azimuth estimations.