Jie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jiangbo Wu
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou, China
5 shared publications - Yao Lv
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
5 shared publications - Yongqing He
Department of Energy and Environment, Southeast University, Nanjing 211189, China
5 shared publications - Wenyu Zhang
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
3 shared publications - Xiaoze Du
Key Laboratory of Power Station Energy Transfer Conversion and System, North China Electric Power University, Ministry of Education, Beijing 102206, China
3 shared publications - Zihan Yan
School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China
2 shared publications
Latest Publications
- Open Access
- 27 February 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 270
Two-Dimensional Simulation on the Critical Diameter of Particles in Asymmetric I-Shaped DLD Arrays
Deterministic lateral displacement (DLD) is a passive particle separation method based on microfluidic technology, with its separation mechanism primarily relying on particle size differences. Therefore, the critical separation size is of great significance in the design of DLD devices. The geometric asymmetry of the pillar array design significantly influences fluid behavior and critical particle size variations. This study first analyzed particle motion characteristics through particle trajectory observation experiments within asymmetric microfluidic chips. Subsequently, a two-dimensional numerical simulation method was employed to investigate the effects of three different ratios of lateral gap size to downstream gap size (Gx:Gy) on particle trajectories and flow field distribution. The results indicate that as Gx:Gy decreases, the upward flow rate gradually reduces, accompanied by changes in the flow field velocity distribution, causing particles to favor displacement mode. This study provides new theoretical foundations for the precise regulation of particle motion behavior and introduces novel insights for optimizing DLD device design.
- 27 February 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 270
Open AccessTwo-Dimensional Simulation on the Critical Diameter of Particles in Asymmetric I-Shaped DLD Arrays
Deterministic lateral displacement (DLD) is a passive particle separation method based on microfluidic technology, with its separation mechanism primarily relying on particle size differences. Therefore, the critical separation size is of great significance in the design of DLD devices. The geometric asymmetry of the pillar array design significantly influences fluid behavior and critical particle size variations. This study first analyzed particle motion characteristics through particle trajectory observation experiments within asymmetric microfluidic chips. Subsequently, a two-dimensional numerical simulation method was employed to investigate the effects of three different ratios of lateral gap size to downstream gap size (Gx:Gy) on particle trajectories and flow field distribution. The results indicate that as Gx:Gy decreases, the upward flow rate gradually reduces, accompanied by changes in the flow field velocity distribution, causing particles to favor displacement mode. This study provides new theoretical foundations for the precise regulation of particle motion behavior and introduces novel insights for optimizing DLD device design.
- Open Access
- 1 March 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (3)
Investigating the impact of pillar shape on flexible erythrocyte separation through deterministic lateral displacement
The deterministic lateral displacement (DLD) method has gradually moved beyond the separation of spherical rigid particles and has been successfully applied to the field of biological cells, especially to the separation of disc-shaped flexible erythrocytes. Different shapes of micropillars in the DLD device significantly affect the sorting performance of erythrocytes. We investigated the effect of the flow field in the gap of micropillars of different shapes (circular, triangular, I-shaped) on the behavior of erythrocyte tumbling motion. The simulation results showed that in the I-shaped pillar DLD device, compared with the circular and triangular pillars, the erythrocytes exhibited a stable and continuous flipping motion during the movement along the array offset direction, which enabled the effective separation size to be maintained at a high level. In addition, the formula for calculating the critical diameter of the I-shaped pillar DLD array for separating erythrocytes was obtained by fitting, which provides strong support for a more efficient design of the I-shaped pillar DLD device dedicated to erythrocyte sorting.
- 1 March 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (3)
Open AccessInvestigating the impact of pillar shape on flexible erythrocyte separation through deterministic lateral displacement
The deterministic lateral displacement (DLD) method has gradually moved beyond the separation of spherical rigid particles and has been successfully applied to the field of biological cells, especially to the separation of disc-shaped flexible erythrocytes. Different shapes of micropillars in the DLD device significantly affect the sorting performance of erythrocytes. We investigated the effect of the flow field in the gap of micropillars of different shapes (circular, triangular, I-shaped) on the behavior of erythrocyte tumbling motion. The simulation results showed that in the I-shaped pillar DLD device, compared with the circular and triangular pillars, the erythrocytes exhibited a stable and continuous flipping motion during the movement along the array offset direction, which enabled the effective separation size to be maintained at a high level. In addition, the formula for calculating the critical diameter of the I-shaped pillar DLD array for separating erythrocytes was obtained by fitting, which provides strong support for a more efficient design of the I-shaped pillar DLD device dedicated to erythrocyte sorting.
- Open Access
- 31 January 2024
- Published by Springer Nature in Research Square
Investigating the Impact of Pillar Shape on Flexible Erythrocyte Separation through Deterministic Lateral Displacement
The deterministic lateral displacement (DLD) method has gradually moved beyond the separation of spherical rigid particles and has been successfully applied to the field of biological cells, especially to the separation of disc-shaped flexible erythrocytes. Different shapes of micropillars in the DLD device significantly affect the sorting performance of erythrocytes. We investigated the effect of the flow field in the gap of micropillars of different shapes (circular, triangular, I-shaped) on the behavior of erythrocyte tumbling motion. The simulation results showed that in the I-shaped pillar DLD device, compared with the circular and triangular pillars, the erythrocytes exhibited a stable and continuous flipping motion during the movement along the array offset direction, which enabled the effective separation size to be maintained at a high level. In addition, the formula for calculating the critical diameter of the I-shaped pillar DLD array for separating erythrocytes was obtained by fitting, which provides strong support for more efficient design of the I-shaped pillar DLD device dedicated to erythrocyte sorting.
- 31 January 2024
- Published by Springer Nature in Research Square
Open AccessInvestigating the Impact of Pillar Shape on Flexible Erythrocyte Separation through Deterministic Lateral Displacement
The deterministic lateral displacement (DLD) method has gradually moved beyond the separation of spherical rigid particles and has been successfully applied to the field of biological cells, especially to the separation of disc-shaped flexible erythrocytes. Different shapes of micropillars in the DLD device significantly affect the sorting performance of erythrocytes. We investigated the effect of the flow field in the gap of micropillars of different shapes (circular, triangular, I-shaped) on the behavior of erythrocyte tumbling motion. The simulation results showed that in the I-shaped pillar DLD device, compared with the circular and triangular pillars, the erythrocytes exhibited a stable and continuous flipping motion during the movement along the array offset direction, which enabled the effective separation size to be maintained at a high level. In addition, the formula for calculating the critical diameter of the I-shaped pillar DLD array for separating erythrocytes was obtained by fitting, which provides strong support for more efficient design of the I-shaped pillar DLD device dedicated to erythrocyte sorting.
- Open Access
- 31 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (2) , 214
Diseased Erythrocyte Enrichment Based on I-Shaped Pillar DLD Arrays
Enrichment of erythrocytes is a necessary step in the diagnosis of blood diseases. Due to the high deformability and viscosity of erythrocytes, they cannot be regarded as stable point-like solids, so the influence of their deformability on fluid dynamics must be considered. Therefore, by using the special effect of an I-shaped pillar (I-pillar) on erythrocytes, erythrocytes with different deformability can be made to produce different provisional distances in the chip, so as to achieve the separation of the two kinds of erythrocytes. In this study, a microfluidic chip was designed to conduct a control test between erythrocytes stored for a long time and fresh erythrocytes. At a specific flow rate, the different deformable erythrocytes in the chip move in different paths. Then, the influence of erythrocyte deformability on its movement trajectory was analyzed by two-dimensional finite element flow simulation. DLD sorting technology provides a new method for the sorting and enrichment of diseased erythrocytes.
- 31 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (2) , 214
Open AccessDiseased Erythrocyte Enrichment Based on I-Shaped Pillar DLD Arrays
Enrichment of erythrocytes is a necessary step in the diagnosis of blood diseases. Due to the high deformability and viscosity of erythrocytes, they cannot be regarded as stable point-like solids, so the influence of their deformability on fluid dynamics must be considered. Therefore, by using the special effect of an I-shaped pillar (I-pillar) on erythrocytes, erythrocytes with different deformability can be made to produce different provisional distances in the chip, so as to achieve the separation of the two kinds of erythrocytes. In this study, a microfluidic chip was designed to conduct a control test between erythrocytes stored for a long time and fresh erythrocytes. At a specific flow rate, the different deformable erythrocytes in the chip move in different paths. Then, the influence of erythrocyte deformability on its movement trajectory was analyzed by two-dimensional finite element flow simulation. DLD sorting technology provides a new method for the sorting and enrichment of diseased erythrocytes.
- Open Access
A Numerical Study on the Erythrocyte Flow Path in I-Shaped Pillar DLD Arrays
Erythrocyte enrichment is needed for blood disease diagnosis and research. DLD arrays with an I-shaped pillar (I-pillar) sort erythrocytes in a unique, accurate, and low-reagent method. However, the existing I-shaped pillar DLD arrays for erythrocyte sorting have the drawbacks of higher flow resistance and more challenging fabrication. A two-dimensional erythrocyte simulation model and the arbitrary Lagrangian–Euler equations at the cell–fluid boundary were built based on the fluid–solid coupling method to investigate the influencing factors of the erythrocyte flow path in an I-pillar DLD array and find its optimization method. Three different sizes of I-pillars were built and multiple sets of corresponding arrays were constructed, followed by finite element simulations to separately investigate the effects of these arrays on the induction of erythrocyte motion paths. This work demonstrates the motion paths of erythrocyte models in a series of I-pillar arrays with different design parameters, aiming to summarize the variation modes of erythrocyte motion paths, which in turn provides some reference for designing and optimizing the pillar size and array arrangement methods for I-pillar array DLD chips.
Open AccessA Numerical Study on the Erythrocyte Flow Path in I-Shaped Pillar DLD Arrays
Erythrocyte enrichment is needed for blood disease diagnosis and research. DLD arrays with an I-shaped pillar (I-pillar) sort erythrocytes in a unique, accurate, and low-reagent method. However, the existing I-shaped pillar DLD arrays for erythrocyte sorting have the drawbacks of higher flow resistance and more challenging fabrication. A two-dimensional erythrocyte simulation model and the arbitrary Lagrangian–Euler equations at the cell–fluid boundary were built based on the fluid–solid coupling method to investigate the influencing factors of the erythrocyte flow path in an I-pillar DLD array and find its optimization method. Three different sizes of I-pillars were built and multiple sets of corresponding arrays were constructed, followed by finite element simulations to separately investigate the effects of these arrays on the induction of erythrocyte motion paths. This work demonstrates the motion paths of erythrocyte models in a series of I-pillar arrays with different design parameters, aiming to summarize the variation modes of erythrocyte motion paths, which in turn provides some reference for designing and optimizing the pillar size and array arrangement methods for I-pillar array DLD chips.