TOThais Ocampo

Thais Ocampo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thais Ocampo has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Does the radiographic image format influence the detection of fractured endodontic instruments in gutta-percha-filled canals?

    by Maria Luiza Santos de Oliveira, Thaís Ocampo, Caio Alencar-Palha, Murilo Miranda-Viana, Deborah Queiroz Freitas, Francisco Haiter-Neto

    Objective: To evaluate the influence of different image file formats on the accuracy of detecting fractured endodontic instruments in gutta-percha–filled root canals. Methods: Thirty-two mandibular molars were instrumented and divided into two groups: case (n = 15), which received a 2 mm fragment of a #35 K-file inside the mesial canal, and control (n = 17), without the fragment. Subsequently, all canals received gutta-percha, and each tooth was placed into a dry human mandible for acquiring radiographs. The radiographs were exported in TIFF, JPEG, BMP, PNG, and DICOM formats, resulting in 160 images (32 radiographs × 5 formats). Six radiologists evaluated the radiographs using a 5-point scale to determine the presence or absence of the fractured instrument. Area under the ROC curve, sensitivity, and specificity were calculated for each evaluator, along with a one-way ANOVA to compare the formats, adopting a 5% significance level. Results: The image file format did not significantly influence the accuracy (p = 767), sensitivity (0.307), or specificity (0.999) in detecting fractured endodontic instruments in filled canals. Conclusions: The study showed similar performance across the image file formats tested for detecting fractured instruments. These results suggest that commonly used and compatible formats can be used without compromising diagnostic accuracy. Advances in knowledge: Instrument fracture is one of the most challenging complications in endodontic treatments, and digital periapical radiographs are widely used in diagnosing this occurrence. The detection and localization of the fragment inside the canal are essential for a favorable prognosis.

  • Open Access

    Humanization of AI-generated abstracts in oral radiology: Role of chatbots and dedicated platforms

    by Caio Alencar-Palha, Thaís Ocampo, Thaísa Pinheiro Silva, Deborah Queiroz Freitas, Frederico Sampaio Neves, Matheus Lima Oliveira

    The rise of generative artificial intelligence (AI) in scientific writing has prompted the development of platforms designed to "humanize" AI-generated text by rephrasing content to reduce its detectability as machine-generated. This study aimed to evaluate the performance of chatbots and dedicated platforms in humanizing AI-generated abstracts. Thirty high-impact scientific articles published in dentomaxillofacial radiology journals were selected. The Methodology and Results sections of each abstract were used to prompt two chatbots—ChatGPT and Gemini—to generate complete abstracts. These AI-generated abstracts were then humanized using the same chatbots along with two dedicated platforms: HumanizeAI and StealthWriter. The percentage of AI-generated content was determined for all abstracts (n = 330), including the original human-written abstracts, using GPTZero. AI detection rates were compared using two-way analysis of variance followed by Tukey's post hoc test (α = 0.05). The results showed that original abstracts and AI-generated abstracts humanized by HumanizeAI and StealthWriter exhibited significantly lower GPTZero detection rates (p < 0.05), whereas abstracts generated or humanized by chatbots showed significantly higher detection rates (p < 0.05). In conclusion, chatbot-generated scientific abstracts humanized by dedicated platforms exhibit low AI detection rates, whereas those humanized by chatbots exhibit considerably higher detection levels. Educators must prepare students with critical appraisal skills to identify AI-generated content and uphold academic integrity, ensuring that AI serves as a complementary tool rather than a means of misrepresentation.

  • Development and assessment of a prototype of an interproximal image receptor-holding device for use in paediatric dentistry

    by Thais Ocampo, Caio Alencar-Palha, Deivi Cascante-Sequeira, Marcela Tarosso Réa, Deborah Queiroz Freitas, Francisco Haiter-Neto

    To develop and test a prototype for interproximal radiography positioning intended for paediatric dentistry and compare the technical quality of image receptor-holding devices (IRHDs) commonly used in clinical practice. Six prototypes, with 3 wedge dimensions (0.5, 1, and 2 mm, respectively) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCP, Hawe Kerr, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child’s skull and mandible. The chi-square and Fisher’s exact tests were employed to analyse significant differences in the number of repetitions and failures in obtaining correct images. A one-way analysis of variance (ANOVA) assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%. The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher’s exact test, revealed a P-value of .057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (P < .0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only 1 radiograph (76.7%) and took less time to execute the technique (1.17 and 1.12 min, respectively). The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.


  • Performance of a Generative Pre‐Trained Transformer in Generating Scientific Abstracts in Dentistry: A Comparative Observational Study

    by Caio Alencar‐Palha, Thais Ocampo, Thaisa Pinheiro Silva, Frederico Sampaio Neves, Matheus L. Oliveira

    Objectives: To evaluate the performance of a Generative Pre‐trained Transformer (GPT) in generating scientific abstracts in dentistry.Methods: Ten scientific articles in dental radiology had their original abstracts collected, while another 10 articles had their methodology and results added to a ChatGPT prompt to generate an All abstracts were randomised and compiled into a single file for subsequent assessment. Five evaluators classified whether the abstract was generated by a human using a 5‐point scale and provided justifications within seven aspects: formatting, information accuracy, orthography, punctuation, terminology, text fluency, and writing style. Furthermore, an online GPT detector provided “Human Score” values, and a plagiarism detector assessed similarity with existing literature.Results: Sensitivity values for detecting human writing ranged from 0.20 to 0.70, with a mean of 0.58; specificity values ranged from 0.40 to 0.90, with a mean of 0.62; and accuracy values ranged from 0.50 to 0.80, with a mean of 0.60. Orthography and Punctuation were the most indicated aspects for the abstract generated by ChatGPT. The GPT detector revealed confidence levels for a “Human Score” of 16.9% for the AI‐generated texts and plagiarism levels averaging 35%.Conclusion: The GPT exhibited commendable performance in generating scientific abstracts when evaluated by humans, as the generated abstracts were indistinguishable from those generated by humans. When evaluated by an online GPT detector, the use of GPT became apparent.


  • Peracetic acid efficacy on disinfection of photostimulable phosphor plates

    by Débora Costa Ruiz, Thaís Santos Cerqueira Ocampo, Eduardo Martinelli Franco, Iago Filipe Correia-Dantas, Renata de Oliveira Mattos-Graner, Francisco Haiter-Neto, Deborah Queiroz Freitas

    To evaluate the antimicrobial efficacy of white vinegar, acetic acid and peracetic acid on photostimulable phosphor (PSP) plates disinfection, and to assess the disinfectant influence on the radiographic quality. Eight PSP plates (Express system) were contaminated with Streptococcus mutans and Candida albicans. These plates were wiped with tissues without any substance, with white vinegar, acetic acid, and peracetic acid, followed by an agar imprint. Number of microbial colonies formed was recorded. Afterwards, the quality of radiographs was tested using the more efficient disinfectant. Before disinfection and after every five disinfections, two radiographs of an acrylic-block and two radiographs of an aluminum step-wedge were acquired for each plate. Density, noise, uniformity, and contrast were analyzed. Three oral radiologists evaluated the images for the presence of artifacts. One-way Analysis of Variance compared changes on gray values among the disinfections (α = 0.05). Intra- and inter-examiner agreement for the presence of artifacts was calculated by weighted Kappa. Peracetic acid was the only one that eliminated both microorganisms. Density and uniformity decreased after 100 disinfections, and contrast changed without a pattern in the course of disinfections (P ≤ 0.05). Small artifacts were observed after 30 disinfections. Intra- and inter-examiner agreements were almost perfect. Disinfection with peracetic acid eliminated both microorganisms. However, it also affected density, uniformity and contrast of radiographs, and led to the formation of small artifacts.


  • Top Cited Papers
    Open Access

    Performance of a commercially available Generative Pre-trained Transformer (GPT) in describing radiolucent lesions in panoramic radiographs and establishing differential diagnoses

    by Thaísa Pinheiro Silva, Maria Fernanda Silva Andrade-Bortoletto, Thaís Santos Cerqueira Ocampo, Caio Alencar-Palha, Michael M. Bornstein, Christiano Oliveira-Santos, Matheus L. Oliveira

    Objectives: To evaluate the performance of a commercially available Generative Pre-trained Transformer (GPT) in describing and establishing differential diagnoses for radiolucent lesions in panoramic radiographs. Materials and methods: Twenty-eight panoramic radiographs, each containing a single radiolucent lesion, were evaluated in consensus by three examiners and a commercially available ChatGPT-3.5 model. They provided descriptions regarding internal structure (radiodensity, loculation), periphery (margin type, cortication), shape, location (bone, side, region, teeth/structures), and effects on adjacent structures (effect, adjacent structure). Diagnostic impressions related to origin, behavior, and nature were also provided. The GPT program was additionally prompted to provide differential diagnoses. Keywords used by the GPT program were compared to those used by the examiners and scored as 0 (incorrect), 0.5 (partially correct), or 1 (correct). Mean score values and standard deviation were calculated for each description. Performance in establishing differential diagnoses was assessed using Rank-1, -2, and − 3. Results: Descriptions of margination, affected bone, and origin received the highest scores: 0.93, 0.93, and 0.87, respectively. Shape, region, teeth/structures, effect, affected region, and nature received considerably lower scores ranging from 0.22 to 0.50. Rank-1, -2, and − 3 demonstrated accuracy in 25%, 57.14%, and 67.85% of cases, respectively. Conclusion: The performance of the GPT program in describing and providing differential diagnoses for radiolucent lesions in panoramic radiographs is variable and at this stage limited in its use for clinical application. Clinical relevance: Understanding the potential role of GPT systems as an auxiliary tool in image interpretation is imperative to validate their clinical applicability.


  • Open Access

    ChatGPT and scientific writing: A reflection on the ethical boundaries

    by Thaís Santos Cerqueira Ocampo, Thaísa Pinheiro Silva, Caio Alencar-Palha, Francisco Haiter-Neto, Matheus L. Oliveira

    Ocampo TS, et al. Imaging Sci Dent. 2023 May;53:e17. https://doi.org/10.5624/isd.20230085


  • Evaluation of different teaching methods in the radiographic diagnosis of proximal carious lesions

    by Beatriz De Carvalho Rocha, Beatriz Salomão Porto-Alegre Rosa, Thaís Santos Cerqueira, Sergio Lins De-Azevedo-Vaz, Gabriella Lopes De Rezende Barbosa, Liana Matos Ferreira, Francielle Silvestre Verner, Maria Augusta Visconti

    Objectives: To evaluate four different teaching methodologies in the radiographic diagnosis of proximal carious lesions and in the students’ perception of these methodologies. Methods: 71 undergraduate dental students were subdivided into 4 groups according to the teaching methodologies used (traditional, hybrid, e-learning and problem-based learning). All methods were applied by two properly trained researchers. Initially, students completed a pre-methodology test (index test). After applying the teaching methodologies, the students were submitted to a post-methodology test containing periapical radiographs for evaluation of proximal carious lesions. Then, the students answered a questionnaire to verify their perception of the different teaching methodologies. Statistical analysis was done. Results: There were no relationship between the results of pre- and post-methodologies tests, irrespective of the teaching methodology employed (p > 0.05). No differences between the teaching methodologies studied (p > 0.05) were found regarding the amount of correct answers. However, the students who participated in the active (e-learning and problem-based learning) and hybrid teaching methodology reported a positive impact in relation to their diagnostic skills at the questionnaire. Conclusions: All the tested methodologies had a similar performance; however, the traditional methodology showed less acceptance by the students when analyzed subjectively and comparatively. The results of the present study increase comprehension about teaching methodologies for radiographic diagnosis of proximal carious lesions, and there is a potential to build on the knowledge base and provide practical support for students and educators.