Hanqing Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hanqing Huang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Zengping Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
2 shared publicationsS. Huang
Hunan Key Laboratory of Multi-Energy System Intelligent Interconnection Technology (HKL-MESI2T), People's Republic of China
1 shared publication- Weibo Qin
China Center for Information Industry Development, CClD, Beijing, China
1 shared publication Y. Zhang
Hunan Key Laboratory of Multi-Energy System Intelligent Interconnection Technology (HKL-MESI2T), People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 22 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (19) , 4375-4385
MMC‐HVDC AC side line protection based on positive sequence fault component current ratio
The high‐voltage direct current (HVDC) transmission based on modular multilevel converter shows the weak feed characteristic of limited fault current amplitude when connected to the traditional AC power grid, which leads to the risk of sensitivity reduction or even failure of the traditional pilot protection. Here, a modular multi‐level converter (MMC)‐HVDC AC side transmission line protection scheme based on positive sequence fault component current ratio is proposed. The positive sequence fault component current of the MMC‐HVDC side is calculated by using the positive sequence fault component current of the power grid side, and the fault is identified through the significant difference between the ratio of the positive sequence fault component current of the MMC‐HVDC side and the actual positive sequence fault component current of the MMC‐HVDC side in the case of internal and external faults. This method has the advantages of simple principle, low requirement for synchronous data, not affected by capacitive current and strong resistance to high resistance. The simulation results show that the algorithm can correctly partition internal and external faults, and is not affected by fault location, fault type and operation mode of converter station, and has high sensitivity and reliability.
- 22 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (19) , 4375-4385
Open AccessMMC‐HVDC AC side line protection based on positive sequence fault component current ratio
The high‐voltage direct current (HVDC) transmission based on modular multilevel converter shows the weak feed characteristic of limited fault current amplitude when connected to the traditional AC power grid, which leads to the risk of sensitivity reduction or even failure of the traditional pilot protection. Here, a modular multi‐level converter (MMC)‐HVDC AC side transmission line protection scheme based on positive sequence fault component current ratio is proposed. The positive sequence fault component current of the MMC‐HVDC side is calculated by using the positive sequence fault component current of the power grid side, and the fault is identified through the significant difference between the ratio of the positive sequence fault component current of the MMC‐HVDC side and the actual positive sequence fault component current of the MMC‐HVDC side in the case of internal and external faults. This method has the advantages of simple principle, low requirement for synchronous data, not affected by capacitive current and strong resistance to high resistance. The simulation results show that the algorithm can correctly partition internal and external faults, and is not affected by fault location, fault type and operation mode of converter station, and has high sensitivity and reliability.
- Open Access
- 23 May 2023
- Published by Wiley
MMC-HVDC AC side Line Protection based on positive sequence Fault component current ratio
The HVDC transmission based on modular multilevel converter shows the weak feed characteristic of limited fault current amplitude when connected to the traditional AC power grid, which leads to the risk of sensitivity reduction or even failure of the traditional pilot protection. In this paper, a MMC-HVDC AC side transmission line protection scheme based on positive sequence fault component current ratio is proposed. The positive sequence fault component current of the MMC-HVDC side is calculated by using the positive sequence fault component current of the power grid side, and the fault is identified through the significant difference between the ratio of the positive sequence fault component current of the MMC-HVDC side and the actual positive sequence fault component current of the MMC-HVDC side in the case of internal and external faults. This method has the advantages of simple principle, low requirement for synchronous data, not affected by capacitive current and strong resistance to high resistance. The simulation results show that the algorithm can correctly partition internal and external faults, and is not affected by fault location, fault type and operation mode of converter station, and has high sensitivity and reliability.
- 23 May 2023
- Published by Wiley
Open AccessMMC-HVDC AC side Line Protection based on positive sequence Fault component current ratio
The HVDC transmission based on modular multilevel converter shows the weak feed characteristic of limited fault current amplitude when connected to the traditional AC power grid, which leads to the risk of sensitivity reduction or even failure of the traditional pilot protection. In this paper, a MMC-HVDC AC side transmission line protection scheme based on positive sequence fault component current ratio is proposed. The positive sequence fault component current of the MMC-HVDC side is calculated by using the positive sequence fault component current of the power grid side, and the fault is identified through the significant difference between the ratio of the positive sequence fault component current of the MMC-HVDC side and the actual positive sequence fault component current of the MMC-HVDC side in the case of internal and external faults. This method has the advantages of simple principle, low requirement for synchronous data, not affected by capacitive current and strong resistance to high resistance. The simulation results show that the algorithm can correctly partition internal and external faults, and is not affected by fault location, fault type and operation mode of converter station, and has high sensitivity and reliability.
- 13 January 2023
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2022 (21) , 366-371
Reliability assessment on the topology of distributed power grid for UAVs
–Due to the special structure of distributed power system on UAV and its critical reliability requirements, it is necessary to build an appropriate reliability evaluation method. This paper presents a reliability evaluation method based on N-K cascading fault model. The method is based on the simulation of power system fault, the calculation of DC power flow, and the analyzing of load shedding under different fault combinations. In order to validate the proposal, case studies are implemented on a solar UAV, where classic topology schemes of distributed power system are evaluated. The results show that the evaluation index is reasonable and the proposed method greatly reduces the computational complexity, thus providing a promising reliability evaluation tool for the optimization of grid topology.
- 13 January 2023
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2022 (21) , 366-371
Reliability assessment on the topology of distributed power grid for UAVs
–Due to the special structure of distributed power system on UAV and its critical reliability requirements, it is necessary to build an appropriate reliability evaluation method. This paper presents a reliability evaluation method based on N-K cascading fault model. The method is based on the simulation of power system fault, the calculation of DC power flow, and the analyzing of load shedding under different fault combinations. In order to validate the proposal, case studies are implemented on a solar UAV, where classic topology schemes of distributed power system are evaluated. The results show that the evaluation index is reasonable and the proposed method greatly reduces the computational complexity, thus providing a promising reliability evaluation tool for the optimization of grid topology.