Gang Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gang Wen has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Hui Li
Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo China
4 shared publications Yujun Tang
Academy of Biomedical Engineering Kunming Medical University Kunming Yunnan China
3 shared publications- Famin Wang
Tianjin University
2 shared publications Hui Li
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230026, P. R. China
2 shared publicationsJiao Li
2 shared publications- Linbo Wang
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230026, P. R. China
2 shared publications
Latest Publications
- 2 September 2026
- Published by Wiley in Laser & Photonics Reviews
Full‐Field‐of‐View Metalens Scanner Optical Module for High‐Speed Imaging Toward Miniaturized Two‐Photon Microscopy
Two‐photon microscopy is a widely used imaging technique in life sciences, offering deep‐tissue penetration and high signal‐to‐noise ratio. However, the performance of miniaturized two‐photon systems is often constrained by the bulky dimensions of conventional objectives, limited aberration correction, and a restricted field of view, which together hinder high‐quality imaging in freely behaving animals. Here, we design and experimentally validate a full‐field‐of‐view metalens scanner optical module based on a gallium nitride metasurface toward high‐speed miniaturized two‐photon microscopy. Guided by generalized Snell's law, the optimized phase profile of the full‐field‐of‐view metalens suppresses off‐axis aberrations and maintains well‐confined focusing over a 100 µm field of view. Transmission and reflection imaging experiments demonstrate that, when integrated with a piezoelectric fiber scanner, the metalens scanner optical module achieves an acquisition rate of 20 fps. The present study does not directly demonstrate two‐photon excitation, fluorescence imaging, or nonlinear optical sectioning, but rather establishes an optical foundation for the future integration of the metalens scanner module into a compact two‐photon fluorescence imaging system.
- 2 September 2026
- Published by Wiley in Laser & Photonics Reviews
Full‐Field‐of‐View Metalens Scanner Optical Module for High‐Speed Imaging Toward Miniaturized Two‐Photon Microscopy
Two‐photon microscopy is a widely used imaging technique in life sciences, offering deep‐tissue penetration and high signal‐to‐noise ratio. However, the performance of miniaturized two‐photon systems is often constrained by the bulky dimensions of conventional objectives, limited aberration correction, and a restricted field of view, which together hinder high‐quality imaging in freely behaving animals. Here, we design and experimentally validate a full‐field‐of‐view metalens scanner optical module based on a gallium nitride metasurface toward high‐speed miniaturized two‐photon microscopy. Guided by generalized Snell's law, the optimized phase profile of the full‐field‐of‐view metalens suppresses off‐axis aberrations and maintains well‐confined focusing over a 100 µm field of view. Transmission and reflection imaging experiments demonstrate that, when integrated with a piezoelectric fiber scanner, the metalens scanner optical module achieves an acquisition rate of 20 fps. The present study does not directly demonstrate two‐photon excitation, fluorescence imaging, or nonlinear optical sectioning, but rather establishes an optical foundation for the future integration of the metalens scanner module into a compact two‐photon fluorescence imaging system.
- Open Access
Physics-driven self-supervised learning for quantitative high-fidelity structured illumination microscopy
Structured illumination microscopy (SIM) enables rapid, long-term super-resolution (SR) imaging of live-cell dynamics. However, current SIM reconstruction methods, although achieving high structural fidelity, generally lack reliable intensity quantification. Here we present qHiFi-SIM, a physics-driven self-supervised learning framework for quantitative high-fidelity SIM imaging. By leveraging the wide-field (WF) image as a physical intensity reference and conventional SIM reconstruction as a structural continuity prior, qHiFi-SIM enables self-supervised training without ground-truth intensity data. It achieves structural fidelity comparable to HiFi-SIM while maintaining excellent intensity linearity at the SIM point-spread function scale (R 2 > 0.986, mean intensity ratio near 1). The framework transfers across diverse SIM setups and typical samples, and directly improves the intensity linearity of other state-of-the-art algorithms without retraining. We demonstrate its utility for live-cell quantitative visualization of mitochondrial intensity dynamics and high-fidelity SIM-FRET functional imaging, offering a practical tool for SR structural visualization and quantitative functional imaging in live cells.
Open AccessPhysics-driven self-supervised learning for quantitative high-fidelity structured illumination microscopy
Structured illumination microscopy (SIM) enables rapid, long-term super-resolution (SR) imaging of live-cell dynamics. However, current SIM reconstruction methods, although achieving high structural fidelity, generally lack reliable intensity quantification. Here we present qHiFi-SIM, a physics-driven self-supervised learning framework for quantitative high-fidelity SIM imaging. By leveraging the wide-field (WF) image as a physical intensity reference and conventional SIM reconstruction as a structural continuity prior, qHiFi-SIM enables self-supervised training without ground-truth intensity data. It achieves structural fidelity comparable to HiFi-SIM while maintaining excellent intensity linearity at the SIM point-spread function scale (R 2 > 0.986, mean intensity ratio near 1). The framework transfers across diverse SIM setups and typical samples, and directly improves the intensity linearity of other state-of-the-art algorithms without retraining. We demonstrate its utility for live-cell quantitative visualization of mitochondrial intensity dynamics and high-fidelity SIM-FRET functional imaging, offering a practical tool for SR structural visualization and quantitative functional imaging in live cells.
- 28 July 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (8) , 1180
Pyramidal lens enables mesoscale structured illumination by surpassing the spatial bandwidth limit of spatial light modulators
Structured illumination has emerged as a pivotal technique in biomedical imaging and machine vision, driving breakthroughs in optical sectioning, super-resolution microscopy, phase imaging, and 3D surface profiling. These applications rely on precise light patterns projected onto samples to extract high-resolution information, where spatial light modulators (SLMs) are widely used for their high speed, precision, and flexibility. However, the limited pixel count of SLMs constrains the spatial bandwidth product (SBP) of structured illumination, creating a tradeoff between the field-of-view (FoV) and spatial resolution. To address this limitation, we develop a mesoscale structured illumination technique that integrates a custom-designed pyramidal lens with an SLM; this technique achieves an unprecedented SBP enhancement of over 100-fold. We demonstrate the generation of mesoscale structured illumination fields containing more than 5000 stripes with a 6-step phase shift using only a 1024-pixel SLM. Leveraging this approach, we further develop a multicolor super-resolution structured illumination microscopy PyramidalSIM, which delivers a reconstructed FoV of 4K pixels and doubled spatial resolution yet utilizes only 609 SLM pixels. Our approach effectively surpasses the intrinsic SBP limitation of SLMs, paving the way for applications such as high-throughput super-resolution imaging and large-scale surface metrology.
- 28 July 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (8) , 1180
Pyramidal lens enables mesoscale structured illumination by surpassing the spatial bandwidth limit of spatial light modulators
Structured illumination has emerged as a pivotal technique in biomedical imaging and machine vision, driving breakthroughs in optical sectioning, super-resolution microscopy, phase imaging, and 3D surface profiling. These applications rely on precise light patterns projected onto samples to extract high-resolution information, where spatial light modulators (SLMs) are widely used for their high speed, precision, and flexibility. However, the limited pixel count of SLMs constrains the spatial bandwidth product (SBP) of structured illumination, creating a tradeoff between the field-of-view (FoV) and spatial resolution. To address this limitation, we develop a mesoscale structured illumination technique that integrates a custom-designed pyramidal lens with an SLM; this technique achieves an unprecedented SBP enhancement of over 100-fold. We demonstrate the generation of mesoscale structured illumination fields containing more than 5000 stripes with a 6-step phase shift using only a 1024-pixel SLM. Leveraging this approach, we further develop a multicolor super-resolution structured illumination microscopy PyramidalSIM, which delivers a reconstructed FoV of 4K pixels and doubled spatial resolution yet utilizes only 609 SLM pixels. Our approach effectively surpasses the intrinsic SBP limitation of SLMs, paving the way for applications such as high-throughput super-resolution imaging and large-scale surface metrology.
- Open Access
- 23 December 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (04)
Direct measurement and optimization of the polarization-dependent modulation depth in super-resolution structured illumination microscopy
Maintaining the s-polarization state of laser beams is important to achieve high modulation depth in a laser-interference-based super-resolution structured illumination microscope (SR-SIM). However, the imperfect optical components can depolarize the laser beams hence degenerating the modulation depth. Here, we first presented a direct measurement method designed to estimate the modulation depth more precisely by shifting illumination patterns with equal phase steps. This measurement method greatly reduces the dependence of modulation depths on the samples, and then developed a polarization optimization method to achieve high modulation depth at all orientations by actively and quantitatively compensating for the additional phase difference using a combination of waveplate and a liquid crystal variable retarder (LCVR). Experimental results demonstrate that our method can achieve illumination patterns with modulation depth higher than 0.94 at three orientations with only one LCVR voltage, which enables isotropic resolution improvement.
- 23 December 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (04)
Open AccessDirect measurement and optimization of the polarization-dependent modulation depth in super-resolution structured illumination microscopy
Maintaining the s-polarization state of laser beams is important to achieve high modulation depth in a laser-interference-based super-resolution structured illumination microscope (SR-SIM). However, the imperfect optical components can depolarize the laser beams hence degenerating the modulation depth. Here, we first presented a direct measurement method designed to estimate the modulation depth more precisely by shifting illumination patterns with equal phase steps. This measurement method greatly reduces the dependence of modulation depths on the samples, and then developed a polarization optimization method to achieve high modulation depth at all orientations by actively and quantitatively compensating for the additional phase difference using a combination of waveplate and a liquid crystal variable retarder (LCVR). Experimental results demonstrate that our method can achieve illumination patterns with modulation depth higher than 0.94 at three orientations with only one LCVR voltage, which enables isotropic resolution improvement.
- Open Access
- 29 October 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (01)
Quantitative evaluation of intensity fidelity of super-resolution reconstruction for structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) relies heavily on post-processing reconstruction to obtain high-quality SR images from raw data. Although many SIM reconstruction algorithms have been developed to recover fine cellular structures with high fidelity even from the noisy data, whether the pixel intensities of reconstructed SR images are still proportional to the original fluorescence intensity has been less explored. The linearity between the intensity before and after reconstruction is defined as the intensity fidelity. Here, we proposed a method to evaluate the reconstructed SR image intensity fidelity at different spatial frequencies. With the proposed metric, we systematically investigated the impact of the key factors on the intensity fidelity in the standard Wiener-SIM reconstructions with simulated data, then evaluated the intensity fidelity of the SR images reconstructed by representative open-source packages. Our work provides a reference for SR-SIM image intensity fidelity improvement.
- 29 October 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (01)
Open AccessQuantitative evaluation of intensity fidelity of super-resolution reconstruction for structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) relies heavily on post-processing reconstruction to obtain high-quality SR images from raw data. Although many SIM reconstruction algorithms have been developed to recover fine cellular structures with high fidelity even from the noisy data, whether the pixel intensities of reconstructed SR images are still proportional to the original fluorescence intensity has been less explored. The linearity between the intensity before and after reconstruction is defined as the intensity fidelity. Here, we proposed a method to evaluate the reconstructed SR image intensity fidelity at different spatial frequencies. With the proposed metric, we systematically investigated the impact of the key factors on the intensity fidelity in the standard Wiener-SIM reconstructions with simulated data, then evaluated the intensity fidelity of the SR images reconstructed by representative open-source packages. Our work provides a reference for SR-SIM image intensity fidelity improvement.
- 8 October 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (20) , 5870-5873
Single-molecule tracking technology based on symmetric power exponential phases
We present a design approach for a symmetric power exponential phase, resulting in a phase-modulated point-spread function with two symmetrical mainlobes that can be steered toward the optical axis opposite the x axis. This design offers nanoscale 3D localization capabilities suitable for 3D single-molecule tracking and localization imaging. The axial probing depth of this symmetric power exponential point-spread function can be adjusted as needed by manipulating specific parameters. Optimization of the symmetric power exponential phase involves truncation filtering to reduce sidelobes and the utilization of a phase inversion-based optimization algorithm to enhance transfer function efficiency and localization precision. A successful multi-molecule 3D tracking experiment was conducted at a 10 µm axial depth using a numerical aperture of 1.4 to validate the efficacy of the proposed design methodology.
- 8 October 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (20) , 5870-5873
Single-molecule tracking technology based on symmetric power exponential phases
We present a design approach for a symmetric power exponential phase, resulting in a phase-modulated point-spread function with two symmetrical mainlobes that can be steered toward the optical axis opposite the x axis. This design offers nanoscale 3D localization capabilities suitable for 3D single-molecule tracking and localization imaging. The axial probing depth of this symmetric power exponential point-spread function can be adjusted as needed by manipulating specific parameters. Optimization of the symmetric power exponential phase involves truncation filtering to reduce sidelobes and the utilization of a phase inversion-based optimization algorithm to enhance transfer function efficiency and localization precision. A successful multi-molecule 3D tracking experiment was conducted at a 10 µm axial depth using a numerical aperture of 1.4 to validate the efficacy of the proposed design methodology.
- 24 May 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (11) , 2949-2952
Keyframe-aided resolution enhancement network for dynamic super-resolution structured illumination microscopy
Deep learning has been used to reconstruct super-resolution structured illumination microscopy (SR-SIM) images with wide-field or fewer raw images, effectively reducing photobleaching and phototoxicity. However, the dependability of new structures or sample observation is still questioned using these methods. Here, we propose a dynamic SIM imaging strategy: the full raw images are recorded at the beginning to reconstruct the SR image as a keyframe, then only wide-field images are recorded. A deep-learning-based reconstruction algorithm, named KFA-RET, is developed to reconstruct the rest of the SR images for the whole dynamic process. With the structure at the keyframe as a reference and the temporal continuity of biological structures, KFA-RET greatly enhances the quality of reconstructed SR images while reducing photobleaching and phototoxicity. Moreover, KFA-RET has a strong transfer capability for observing new structures that were not included during network training.
- 24 May 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (11) , 2949-2952
Keyframe-aided resolution enhancement network for dynamic super-resolution structured illumination microscopy
Deep learning has been used to reconstruct super-resolution structured illumination microscopy (SR-SIM) images with wide-field or fewer raw images, effectively reducing photobleaching and phototoxicity. However, the dependability of new structures or sample observation is still questioned using these methods. Here, we propose a dynamic SIM imaging strategy: the full raw images are recorded at the beginning to reconstruct the SR image as a keyframe, then only wide-field images are recorded. A deep-learning-based reconstruction algorithm, named KFA-RET, is developed to reconstruct the rest of the SR images for the whole dynamic process. With the structure at the keyframe as a reference and the temporal continuity of biological structures, KFA-RET greatly enhances the quality of reconstructed SR images while reducing photobleaching and phototoxicity. Moreover, KFA-RET has a strong transfer capability for observing new structures that were not included during network training.
- Open Access
- 10 March 2021
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 9
High Dynamic Range Structured Illumination Microscope Based on Multiple Exposures
Structured illumination microscope (SIM) can double the spatial resolution by using fringed pattern illumination. However, for samples with large intra-scene dynamic ranges, such as clustered objects, SIM fails to reconstruct high-quality images and often exhibits strong artifacts. Herein, we present a high dynamic range SIM (HDR-SIM) method using a multi-exposure acquisition strategy. With HDR-SIM, individual and clustered microspheres and vesicles with 420 times intensity differences can be visualized in the same scene while the delicate structures of the sample were preserved effectively.
- 10 March 2021
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 9
Open AccessHigh Dynamic Range Structured Illumination Microscope Based on Multiple Exposures
Structured illumination microscope (SIM) can double the spatial resolution by using fringed pattern illumination. However, for samples with large intra-scene dynamic ranges, such as clustered objects, SIM fails to reconstruct high-quality images and often exhibits strong artifacts. Herein, we present a high dynamic range SIM (HDR-SIM) method using a multi-exposure acquisition strategy. With HDR-SIM, individual and clustered microspheres and vesicles with 420 times intensity differences can be visualized in the same scene while the delicate structures of the sample were preserved effectively.
- Open Access
HiFi-SIM: reconstructing high-fidelity structured illumination microscope images
Structured illumination microscopy (SIM) has been a widely-used super-resolution (SR) fluorescence microscopy technique, but artifacts often appear in reconstructed SR images which reduce its fidelity and might cause misinterpretation of biological structures. We present HiFi-SIM, a high-fidelity SIM reconstruction algorithm, by engineering the effective point spread function (PSF) into an ideal form. HiFi-SIM can effectively reduce commonly-seen artifacts without loss of fine structures and improve the axial sectioning. Since results of HiFi-SIM are not sensitive to used PSF and reconstruction parameters, it lowers the requirements for dedicated PSF calibration and complicated parameter adjustment, thus promoting SIM as a daily imaging tool.
Open AccessHiFi-SIM: reconstructing high-fidelity structured illumination microscope images
Structured illumination microscopy (SIM) has been a widely-used super-resolution (SR) fluorescence microscopy technique, but artifacts often appear in reconstructed SR images which reduce its fidelity and might cause misinterpretation of biological structures. We present HiFi-SIM, a high-fidelity SIM reconstruction algorithm, by engineering the effective point spread function (PSF) into an ideal form. HiFi-SIM can effectively reduce commonly-seen artifacts without loss of fine structures and improve the axial sectioning. Since results of HiFi-SIM are not sensitive to used PSF and reconstruction parameters, it lowers the requirements for dedicated PSF calibration and complicated parameter adjustment, thus promoting SIM as a daily imaging tool.