Jaroslav Cerovsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaroslav Cerovsky has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Ondrej Ficker
Institute of Plasma Physics of the CAS
5 shared publications - Jaroslav Krbec
Institute of Plasma Physics Czech Academy of Sciences
3 shared publications - Vladimir Weinzettl
Institute of Plasma Physics of the Czech Academy of Sciences, U Slovanky 2525/1a, 182 00, Prague 8, Czech Republic
3 shared publications E. Tomesova
Institute of the Plasma Physics of the Czech Academy of Sciences 1 , Prague 18200
2 shared publications- Fabien Jaulmes
Institute of Plasma Physics of the Czech Academy of Sciences
2 shared publications - Gabor Cseh
HUN-REN Centre for Energy Research, Konkoly-Thege út 29-33, 1121 Budapest, Hungary
2 shared publications
Latest Publications
- 21 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
- 21 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
- Open Access
- 16 June 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (7)
Modelling and inversion of bremsstrahlung from runaway electrons on the GOLEM tokamak
Runaway electron (RE) losses are usually diagnosed with a small number of hard X-ray (HXR) detectors, which provide limited spatial information. Although multi-chord HXR spectrometers on large devices allow reconstruction of RE parameters in the plasma volume, equivalent methods for localized RE losses at plasma-facing components are scarce. We investigated the feasibility of inferring the RE strike-point position and in principle, pitch from bremsstrahlung generated at the poloidal limiter of the GOLEM tokamak. Geant4 simulations were used to construct a forward model, and synthetic detector signals were inverted with a tomographic algorithm. Benchmark tests indicated that strike-point localization should be possible with modest detector coverage, but pitch inference requires substantially more. With only five detectors available, we were able to demonstrate strike-point localization but no pitch estimation in the experiment. The results demonstrate the potential of thick-target bremsstrahlung as a diagnostic of RE losses.
- 16 June 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (7)
Open AccessModelling and inversion of bremsstrahlung from runaway electrons on the GOLEM tokamak
Runaway electron (RE) losses are usually diagnosed with a small number of hard X-ray (HXR) detectors, which provide limited spatial information. Although multi-chord HXR spectrometers on large devices allow reconstruction of RE parameters in the plasma volume, equivalent methods for localized RE losses at plasma-facing components are scarce. We investigated the feasibility of inferring the RE strike-point position and in principle, pitch from bremsstrahlung generated at the poloidal limiter of the GOLEM tokamak. Geant4 simulations were used to construct a forward model, and synthetic detector signals were inverted with a tomographic algorithm. Benchmark tests indicated that strike-point localization should be possible with modest detector coverage, but pitch inference requires substantially more. With only five detectors available, we were able to demonstrate strike-point localization but no pitch estimation in the experiment. The results demonstrate the potential of thick-target bremsstrahlung as a diagnostic of RE losses.
- Open Access
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
COMPASS Upgrade (COMPASS-U) [1] is a high-magnetic field (5 T) tokamak, currently being built at the Institute of Plasma Physics in Prague. The HUN-REN Centre for Energy Research plans to develop a pellet injector for COMPASS-U. This work aims to optimize the pellet injector parameters - pellet velocity, size, injection direction, and investigates the pellet-plasma interaction, using various plasma scenarios of the Compass Upgrade tokamak with the HPI2 code [2]. HPI2 is a widely used pellet injection simulation code that can handle 3D geometries and related secondary phenomena, like inhomogeneous pellet ablation.The dependence of material deposition and penetration depth on pellet size and velocity were examined, and for the desired material deposition, pellets with a radius of 0.75 mm should be injected into the plasma. Higher injection velocity is advantageous, but based on technical considerations, simulations were run using an injection velocity of 500 m/s.The properties of different injection directions were explored, in several scenarios, from early L-mode to the high-performance H-mode scenario, based on which the optimal injection geometry of the pellet injector was defined. While LFS injection is the easiest to realize technically, it results in the least efficient fuelling, as expected, as drift phenomena quickly accelerates the pellet cloud out from the plasma. The internal, HFS injection is the most efficient, where the drift direction points inward the plasma; due to accessibility constraints, pellets cannot be delivered here. A good compromise is the vertical (VHFS) injection, from an existing port. Relaxation of the plasma profiles after the injection were also investigated to characterise the pacing requirements of the injection.[1]: M. Komm et al, COMPASS Upgrade: a high-field tokamak for ITER- and DEMO-relevant research (2024) Nucl. Fusion 64 076028[2]: F. Koechl et al, Modelling of Pellet Particle Ablation and Deposition: The Hydrogen Pellet Injection code HPI2 (2014), EFDA–JET–PR(12)57, Nuclear Fusion
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
COMPASS Upgrade (COMPASS-U) [1] is a high-magnetic field (5 T) tokamak, currently being built at the Institute of Plasma Physics in Prague. The HUN-REN Centre for Energy Research plans to develop a pellet injector for COMPASS-U. This work aims to optimize the pellet injector parameters - pellet velocity, size, injection direction, and investigates the pellet-plasma interaction, using various plasma scenarios of the Compass Upgrade tokamak with the HPI2 code [2]. HPI2 is a widely used pellet injection simulation code that can handle 3D geometries and related secondary phenomena, like inhomogeneous pellet ablation.The dependence of material deposition and penetration depth on pellet size and velocity were examined, and for the desired material deposition, pellets with a radius of 0.75 mm should be injected into the plasma. Higher injection velocity is advantageous, but based on technical considerations, simulations were run using an injection velocity of 500 m/s.The properties of different injection directions were explored, in several scenarios, from early L-mode to the high-performance H-mode scenario, based on which the optimal injection geometry of the pellet injector was defined. While LFS injection is the easiest to realize technically, it results in the least efficient fuelling, as expected, as drift phenomena quickly accelerates the pellet cloud out from the plasma. The internal, HFS injection is the most efficient, where the drift direction points inward the plasma; due to accessibility constraints, pellets cannot be delivered here. A good compromise is the vertical (VHFS) injection, from an existing port. Relaxation of the plasma profiles after the injection were also investigated to characterise the pacing requirements of the injection.[1]: M. Komm et al, COMPASS Upgrade: a high-field tokamak for ITER- and DEMO-relevant research (2024) Nucl. Fusion 64 076028[2]: F. Koechl et al, Modelling of Pellet Particle Ablation and Deposition: The Hydrogen Pellet Injection code HPI2 (2014), EFDA–JET–PR(12)57, Nuclear Fusion
- Open Access
- 1 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035008
Design of the soft x-ray spectrometer for observing high- Z elements at the full-metal COMPASS Upgrade tokamak
A compact and highly flexible soft x-ray (SXR) spectrometer for measuring electromagnetic radiation, primarily in the spectral range of about 2–8 keV, was designed with the aim of monitoring of highly ionized, mainly high- Z metallic impurities in the core of high temperature plasmas at the COMPASS Upgrade tokamak (currently under construction) with core plasma temperatures of ∼1–5 keV and core electron densities of ∼1–3 * 10 20 m −3 . These impurities will originate from plasma interaction with plasma-facing components made of tungsten and nickel–chromium-based alloys (Inconel), containing elements such as nickel, chromium, molybdenum and iron. The SXR spectrometer will enable the monitoring of each of these elements by resolving well their characteristic spectral lines in pre-selected spectral regions of interest. Additionally, information on the electron and ion temperature in the plasma core will be provided using artificially introduced impurities such as argon. The main technical parameters of the SXR spectrometer are as follows: Johann geometry using spherical Bragg crystals, back-illuminated charge-coupled device as a detector in a fixed position, pre-selected spectral regions of interest for metallic (W, Mo, Fe, Cr, Ni) and gaseous (Ar) impurities in the spectral region 2.4–8.1 keV (0.52–0.15 nm), spectral resolution about 2500, but better than 3000 for the Ar lines near 3.1 keV, time resolution about 40 ms, compact size (the core of the spectrometer of about 1 m by 1 m; 2.5 m long vacuum connection duct to the tokamak cryostat edge) and flexible configuration (remotely driven crystal exchanger, left–right spectrometer set-up flexibility, differential pumping). The contribution introduces the design of the spectrometer itself as well as future plans for its implementation in the tokamak hall in early operational phases with low hard radiation or in a shielded area outside the tokamak hall for high-performance plasmas at COMPASS Upgrade.
- 1 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035008
Open AccessDesign of the soft x-ray spectrometer for observing high- Z elements at the full-metal COMPASS Upgrade tokamak
A compact and highly flexible soft x-ray (SXR) spectrometer for measuring electromagnetic radiation, primarily in the spectral range of about 2–8 keV, was designed with the aim of monitoring of highly ionized, mainly high- Z metallic impurities in the core of high temperature plasmas at the COMPASS Upgrade tokamak (currently under construction) with core plasma temperatures of ∼1–5 keV and core electron densities of ∼1–3 * 10 20 m −3 . These impurities will originate from plasma interaction with plasma-facing components made of tungsten and nickel–chromium-based alloys (Inconel), containing elements such as nickel, chromium, molybdenum and iron. The SXR spectrometer will enable the monitoring of each of these elements by resolving well their characteristic spectral lines in pre-selected spectral regions of interest. Additionally, information on the electron and ion temperature in the plasma core will be provided using artificially introduced impurities such as argon. The main technical parameters of the SXR spectrometer are as follows: Johann geometry using spherical Bragg crystals, back-illuminated charge-coupled device as a detector in a fixed position, pre-selected spectral regions of interest for metallic (W, Mo, Fe, Cr, Ni) and gaseous (Ar) impurities in the spectral region 2.4–8.1 keV (0.52–0.15 nm), spectral resolution about 2500, but better than 3000 for the Ar lines near 3.1 keV, time resolution about 40 ms, compact size (the core of the spectrometer of about 1 m by 1 m; 2.5 m long vacuum connection duct to the tokamak cryostat edge) and flexible configuration (remotely driven crystal exchanger, left–right spectrometer set-up flexibility, differential pumping). The contribution introduces the design of the spectrometer itself as well as future plans for its implementation in the tokamak hall in early operational phases with low hard radiation or in a shielded area outside the tokamak hall for high-performance plasmas at COMPASS Upgrade.
- Open Access
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
A lanthanum bromide detector of runaway electrons for TCV
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼8MeV on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Open AccessA lanthanum bromide detector of runaway electrons for TCV
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼8MeV on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Calorimetry probe for runaway electron heat load measurement at COMPASS
Runaway electrons, accelerated in a tokamak discharge to high energies (tens of MeV), can cause serious damage to plasma facing components. Therefore, it is important to develop effective mitigation strategies to reduce the risk of tokamak damage. To study the effects of various mitigation strategies, a dedicated diagnostic, the calorimetry probe, was developed at the COMPASS tokamak. This probe successfully measured the heat loads caused by runaway electrons directly, using a set of temperature sensors embedded in a graphite body. Deposited energy measured by the probe ranged from a few hundred joules up to (15 ± 1) kJ, while the mean deposited energy was (4.5 ± 1.1) kJ. The design of the probe and the initial results from 250 discharges covering four experimental campaigns dedicated to runaway electron studies (2019–2021) are presented in this article.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Calorimetry probe for runaway electron heat load measurement at COMPASS
Runaway electrons, accelerated in a tokamak discharge to high energies (tens of MeV), can cause serious damage to plasma facing components. Therefore, it is important to develop effective mitigation strategies to reduce the risk of tokamak damage. To study the effects of various mitigation strategies, a dedicated diagnostic, the calorimetry probe, was developed at the COMPASS tokamak. This probe successfully measured the heat loads caused by runaway electrons directly, using a set of temperature sensors embedded in a graphite body. Deposited energy measured by the probe ranged from a few hundred joules up to (15 ± 1) kJ, while the mean deposited energy was (4.5 ± 1.1) kJ. The design of the probe and the initial results from 250 discharges covering four experimental campaigns dedicated to runaway electron studies (2019–2021) are presented in this article.
- 20 February 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 201
Installation of the room temperature solid state pellet injector for investigation of runaway electrons at the COMPASS tokamak
- 20 February 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 201
Installation of the room temperature solid state pellet injector for investigation of runaway electrons at the COMPASS tokamak
- Open Access
- 23 May 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (8) , 085501
A new hard x-ray spectrometer for runaway electron measurements in tokamaks
Runaway electron gamma-ray detection system, a novel hard x-ray (HXR) spectrometer optimized for bremsstrahlung radiation measurement from runaway electrons in fusion plasmas, has been developed. The detector is based on a 1‘×1’ LaBr3:Ce scintillator crystal coupled with a photomultiplier tube. The system has an energy dynamic range exceeding 20 MeV with an energy resolution of 3% at 661.7 keV. The detector gain is stable even under severe loads, with a gain shift that stays below 3% at HXR counting rates in excess of 1 MCps. The performance of the system enables unprecedented studies of the time-dependent runaway electron energy distribution function, as shown in recent runaway electron physics experiments at the ASDEX Upgrade and COMPASS tokamaks.
- 23 May 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (8) , 085501
Open AccessA new hard x-ray spectrometer for runaway electron measurements in tokamaks
Runaway electron gamma-ray detection system, a novel hard x-ray (HXR) spectrometer optimized for bremsstrahlung radiation measurement from runaway electrons in fusion plasmas, has been developed. The detector is based on a 1‘×1’ LaBr3:Ce scintillator crystal coupled with a photomultiplier tube. The system has an energy dynamic range exceeding 20 MeV with an energy resolution of 3% at 661.7 keV. The detector gain is stable even under severe loads, with a gain shift that stays below 3% at HXR counting rates in excess of 1 MCps. The performance of the system enables unprecedented studies of the time-dependent runaway electron energy distribution function, as shown in recent runaway electron physics experiments at the ASDEX Upgrade and COMPASS tokamaks.