Axel Jacobsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Axel Jacobsen has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Paul Lebel
Chan Zuckerberg Biohub San Francisco
6 shared publications - Rafael Gómez-Sjöberg
Chan Zuckerberg Biohub San Francisco
6 shared publications - Chris Charlton
Chan Zuckerberg Biohub San Francisco
4 shared publications - Emily Huynh
Chan Zuckerberg Biohub San Francisco
4 shared publications - Greg Courville
Chan Zuckerberg Biohub San Francisco , 499 Illinois St, San Francisco, CA 94158
4 shared publications - Ilakkiyan Jeyakumar
Chan Zuckerberg Biohub San Francisco
4 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 4 (12)
Open-source cell culture automation system with integrated cell counting for passaging microplate cultures
Tissue culture in 96-well microplates is conventionally a tedious, highly manual process sensitive to individual technique and experimenter error. Here, we describe the Automated Cell Culture Splitter, a system for passaging plates of adherent or suspension cells, for routine culture maintenance or specialized applications such as seeding plates for microscopy. The system is built around the Opentrons OT-2 liquid handling robot and incorporates a novel on-deck imaging-based cell counter which allows it to compensate for density disparities across a source plate and control the number of cells seeded on a per-well basis. We find this solution can cut hands-on time by 61% and the results compare favorably to our existing manual cell culture processes in terms of both seeding density precision and biological outcomes, achieving a control of seeding density with a well-to-well coefficient of variation under 11%. The system is designed to be adaptable and an accessible entry point into automation for high-throughput cell culture; to that end, all of the source code and hardware designs are released under open source licenses.
- 1 December 2025
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 4 (12)
Open AccessOpen-source cell culture automation system with integrated cell counting for passaging microplate cultures
Tissue culture in 96-well microplates is conventionally a tedious, highly manual process sensitive to individual technique and experimenter error. Here, we describe the Automated Cell Culture Splitter, a system for passaging plates of adherent or suspension cells, for routine culture maintenance or specialized applications such as seeding plates for microscopy. The system is built around the Opentrons OT-2 liquid handling robot and incorporates a novel on-deck imaging-based cell counter which allows it to compensate for density disparities across a source plate and control the number of cells seeded on a per-well basis. We find this solution can cut hands-on time by 61% and the results compare favorably to our existing manual cell culture processes in terms of both seeding density precision and biological outcomes, achieving a control of seeding density with a well-to-well coefficient of variation under 11%. The system is designed to be adaptable and an accessible entry point into automation for high-throughput cell culture; to that end, all of the source code and hardware designs are released under open source licenses.
- 9 July 2025
- Published by Oxford University Press (OUP) in Transactions of the Royal Society of Tropical Medicine and Hygiene
- Vol. 119 (9) , 1100-1111
Remoscope: a label-free imaging cytometer for malaria diagnostics
Background: Malaria diagnostic testing remains a burden on healthcare systems. Here we present Remoscope, a portable imaging cytometer that scans fresh, unstained whole blood using a custom neural network running on low-cost hardware. Remoscope performs label-free, quantitative, stage-specific detection of Plasmodium falciparum (Pf) by screening up to 2 million red blood cells (RBCs) in 1–12 min, without sample fixation, staining or slide scanning. Low-cost disposable cartridges are used to confine flowing blood to an ultrathin sheet for imaging. Methods: Performance was benchmarked in vitro by titration of cultured Pf (17.1–710 000 parasites/µl) into whole blood. A study of Remoscope's diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitaemia were performed using Remoscope, quantitative polymerase chain reaction (qPCR) and thick blood smears. Results: Clinically, Remoscope's 10× diluted blood assay had a limit of detection with respect to qPCR of 95.1 parasites/µl, sensitivity of 83%, specificity of 96%, positive predictive value of 91% and negative predictive value of 93%. Conclusions: Remoscope's speed, accuracy, cost and ease of use address key challenges in malaria diagnosis worldwide. In this pilot study, the diagnostic accuracy approaches that of expert thick smears performed in duplication.
- 9 July 2025
- Published by Oxford University Press (OUP) in Transactions of the Royal Society of Tropical Medicine and Hygiene
- Vol. 119 (9) , 1100-1111
Remoscope: a label-free imaging cytometer for malaria diagnostics
Background: Malaria diagnostic testing remains a burden on healthcare systems. Here we present Remoscope, a portable imaging cytometer that scans fresh, unstained whole blood using a custom neural network running on low-cost hardware. Remoscope performs label-free, quantitative, stage-specific detection of Plasmodium falciparum (Pf) by screening up to 2 million red blood cells (RBCs) in 1–12 min, without sample fixation, staining or slide scanning. Low-cost disposable cartridges are used to confine flowing blood to an ultrathin sheet for imaging. Methods: Performance was benchmarked in vitro by titration of cultured Pf (17.1–710 000 parasites/µl) into whole blood. A study of Remoscope's diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitaemia were performed using Remoscope, quantitative polymerase chain reaction (qPCR) and thick blood smears. Results: Clinically, Remoscope's 10× diluted blood assay had a limit of detection with respect to qPCR of 95.1 parasites/µl, sensitivity of 83%, specificity of 96%, positive predictive value of 91% and negative predictive value of 93%. Conclusions: Remoscope's speed, accuracy, cost and ease of use address key challenges in malaria diagnosis worldwide. In this pilot study, the diagnostic accuracy approaches that of expert thick smears performed in duplication.
- Open Access
Open-source cell culture automation system with integrated cell counting for passaging microplate cultures
Tissue culture in 96-well microplates is conventionally a tedious, highly manual process sensitive to individual technique and experimenter error. Here, we describe the Automated Cell Culture Splitter (ACCS), a system for passaging plates of adherent or suspension cells, for routine culture maintenance or specialized applications such as seeding plates for microscopy. The system is built around the Opentrons OT-2 liquid handling robot and incorporates a novel on-deck imaging-based cell counter which allows it to compensate for density disparities across a source plate and control the number of cells seeded on a per-well basis. We find this solution can cut hands-on time by 61% and the results compare favorably to our existing manual cell culture processes in terms of both seeding density precision and bio-logical outcomes, achieving a control of seeding density with a well-to-well coefficient of variation (CV) under 11%. The system is designed to be adaptable and an accessible entry point into automation for high-throughput cell culture; to that end, all of the source code and hardware designs are released under open source licenses.
Open AccessOpen-source cell culture automation system with integrated cell counting for passaging microplate cultures
Tissue culture in 96-well microplates is conventionally a tedious, highly manual process sensitive to individual technique and experimenter error. Here, we describe the Automated Cell Culture Splitter (ACCS), a system for passaging plates of adherent or suspension cells, for routine culture maintenance or specialized applications such as seeding plates for microscopy. The system is built around the Opentrons OT-2 liquid handling robot and incorporates a novel on-deck imaging-based cell counter which allows it to compensate for density disparities across a source plate and control the number of cells seeded on a per-well basis. We find this solution can cut hands-on time by 61% and the results compare favorably to our existing manual cell culture processes in terms of both seeding density precision and bio-logical outcomes, achieving a control of seeding density with a well-to-well coefficient of variation (CV) under 11%. The system is designed to be adaptable and an accessible entry point into automation for high-throughput cell culture; to that end, all of the source code and hardware designs are released under open source licenses.
- Open Access
Remoscope: a label-free imaging cytometer for malaria diagnostics
Malaria diagnostic testing in high transmission settings remains a burden on healthcare systems. Here we present Remoscope, a portable automated imaging cytometer that scans fresh, unstained whole blood using a custom neural network on low-cost hardware. By screening up to two million red blood cells, Remoscope performs label-free quantitative stage-specific detection of Plasmodium falciparum ( Pf ) in 1-12 minutes without sample fixation, staining, or slide scanning. Flow is used to achieve high cellular throughput, with blood confined to a 4.5 µm monolayer in low-cost disposable flow cartridges. Remoscope performance was benchmarked in vitro by titration of cultured parasites into uninfected whole blood at concentrations of 17.1-710,000 parasites/µL. Counts generated by Remoscope demonstrated a linear response across the entire range. Considering drug susceptibility assays, the half-maximal effective concentration (EC50) of chloroquine (CQ) for the W2 strain of Pf was 211 nM by Remoscope, compared to 191 nM for conventional flow cytometry. Remoscope’s real-world diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitemia were performed using Remoscope, qPCR targeting the multicopy conserved var gene acidic terminal sequence, and microscopic evaluation of Giemsa-stained thick blood smears. Remoscope’s limit of detection with respect to qPCR was 95.1 parasites/µL. At this threshold, the system had a sensitivity of 83%, specificity of 96%, Positive Predictive Value (PPV) of 91%, and a Negative Predictive Value (NPV) of 93%. Remoscope’s speed, accuracy, low cost, and ease of use address practical challenges in malaria diagnostic settings around the world. As a general imaging flow cytometer, Remoscope may also inform the development of recognition models for the diagnosis of other infectious and noninfectious blood disorders.
Open AccessRemoscope: a label-free imaging cytometer for malaria diagnostics
Malaria diagnostic testing in high transmission settings remains a burden on healthcare systems. Here we present Remoscope, a portable automated imaging cytometer that scans fresh, unstained whole blood using a custom neural network on low-cost hardware. By screening up to two million red blood cells, Remoscope performs label-free quantitative stage-specific detection of Plasmodium falciparum ( Pf ) in 1-12 minutes without sample fixation, staining, or slide scanning. Flow is used to achieve high cellular throughput, with blood confined to a 4.5 µm monolayer in low-cost disposable flow cartridges. Remoscope performance was benchmarked in vitro by titration of cultured parasites into uninfected whole blood at concentrations of 17.1-710,000 parasites/µL. Counts generated by Remoscope demonstrated a linear response across the entire range. Considering drug susceptibility assays, the half-maximal effective concentration (EC50) of chloroquine (CQ) for the W2 strain of Pf was 211 nM by Remoscope, compared to 191 nM for conventional flow cytometry. Remoscope’s real-world diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitemia were performed using Remoscope, qPCR targeting the multicopy conserved var gene acidic terminal sequence, and microscopic evaluation of Giemsa-stained thick blood smears. Remoscope’s limit of detection with respect to qPCR was 95.1 parasites/µL. At this threshold, the system had a sensitivity of 83%, specificity of 96%, Positive Predictive Value (PPV) of 91%, and a Negative Predictive Value (NPV) of 93%. Remoscope’s speed, accuracy, low cost, and ease of use address practical challenges in malaria diagnostic settings around the world. As a general imaging flow cytometer, Remoscope may also inform the development of recognition models for the diagnosis of other infectious and noninfectious blood disorders.
- Open Access
- 21 February 2024
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 4 (2) , e0002766
A handheld luminometer with sub-attomole limit of detection for distributed applications in global health
Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ~$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase. Using these devices, we performed two pilot cross-sectional serology studies to assess sars-cov-2 antibody levels: a cohort in the United States, as well as a field study in Bangladesh. Results from both studies were consistent with previous work and demonstrate the device’s suitability for distributed applications in global health.
- 21 February 2024
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 4 (2) , e0002766
Open AccessA handheld luminometer with sub-attomole limit of detection for distributed applications in global health
Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ~$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase. Using these devices, we performed two pilot cross-sectional serology studies to assess sars-cov-2 antibody levels: a cohort in the United States, as well as a field study in Bangladesh. Results from both studies were consistent with previous work and demonstrate the device’s suitability for distributed applications in global health.
- Open Access
A handheld luminometer with sub-attomole limit of detection for distributed applications in global health
Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ∼$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase, or approximately 1fW of radiant optical power. Using these devices, we performed split luciferase serology studies to monitor sars-cov-2 antibodies in a cohort in the United States, as well as a field study in Bangladesh.
Open AccessA handheld luminometer with sub-attomole limit of detection for distributed applications in global health
Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ∼$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase, or approximately 1fW of radiant optical power. Using these devices, we performed split luciferase serology studies to monitor sars-cov-2 antibodies in a cohort in the United States, as well as a field study in Bangladesh.
- 6 June 2012
- Published by Springer Nature in Journal of Materials Science
- Vol. 47 (18) , 6621-6632
Effects of material heterogeneities on the compressive response of thiol-ene pyramidal lattices
- 6 June 2012
- Published by Springer Nature in Journal of Materials Science
- Vol. 47 (18) , 6621-6632
Effects of material heterogeneities on the compressive response of thiol-ene pyramidal lattices