ABAbdelkader Bekri

Abdelkader Bekri

*This is an algorithmically generated author record based on publicly available information.

Abdelkader Bekri has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Flight Control of a Quadrotor by Backstepping/PID

    by Mohammed Elamine Sabri, Abdlkader Bekri, Abdjabbar Hazzab

    The quadrotor is an unmanned aerial vehicle (UAV) with four rotors, able to carry out a multitude of missions. This paper consists of establishing nonlinear laws of command to control the movement of this engine. Firstly a dynamic model, taking care of the all the phenomenon which govern the movement of the helicopter, has been developed. Secondly two approaches of control one classic, the other uses the backstepping. Thereafter, a new strategy has been proposed to improve the performance of control. The control law of this technique is developed using backstepping based on the PID. The results of simulation show the performance of this command.

  • Open Access

    Designing fuzzy membership functions using genetic algorithm with a new encoding method

    by Ali Hamed, Slimane Hireche, Abdelkader Bekri, Ahmed Cheriet

    This article presents a new method for designing fuzzy membership functions using the genetic algorithm (GA) without the use of constraints. Conventional approaches to designing these functions often involve manual tuning or optimization techniques with limitations. However, this article introduces a constraint-free approach, as the GA requires all constraints to be met for a chromosome; if even one condition is not satisfied, the chromosome is discarded, regardless of its ideal values for other variables. Consequently, a high number of constraints, especially in the studied case, increases the likelihood of chromosome rejection, leading to a time-consuming design process and suboptimal results.

  • Open Access

    Small signal stability and dynamic performance investigation on multi-machines power system including DFIG wind farm

    by Khaled Kouider, Abdelkader Bekri

    The boundless potential of wind power in augmenting global energy production is a promising prospect. The efficient design and cost-effectiveness of doubly fed induction generator (DFIG) wind systems make them an optimistic solution for incorporating wind power on a massive scale. However, integrating these systems into power grids poses several challenges, including power system stability. This study examines the small signal stability and dynamic performance of a modified Western System Coordinating Council (WSCC) 9-bus system including a DFIG wind farm using load flow analysis, and both electromechanical oscillations and eigenvalue analysis. Three case studies were conducted based on the DFIG location and power increment.The simulation is carried out with the aid of the power system analysis toolbox (PSAT) that operates within the MATLAB environment. The study’s findings suggest that the perturbation and location of the DFIG relative to the system’s load have a minimal influence on the overall system’s stability and efficiency. However, when considering damping ratio, power angle, and rotor speed deviations, generators 1 and 2 with the perturbed DFIG installed on bus 8 are the most sensitive units to instability. Hence, larger perturbations and different DFIG’s location influence on power systems necessitates further analysis.


  • Open Access

    Enhancing transient stability and dynamic response of wind-penetrated power systems through PSS and STATCOM cooperation

    by Khaled Kouider, Abdelkader Bekri

    The large-scale integration of doubly-fed induction generator (DFIG) based wind power plants poses stability challenges for power system operation. This study investigates the transient stability and dynamic performance of a modified 3-machine, 9-bus Western System Coordinating Council (WSCC) system. The investigation was conducted by connecting the DFIG wind farm to the sixth bus via a low-impedance transmission line and installing power system stabilizers (PSSs) on all automatic voltage regulators (AVRs). A three-phase fault simulation was carried out to test the system, with and without power system stabilizers and a static synchronous compensator (STATCOM) device. Time-domain simulations demonstrate improved transient response with PSS-STATCOM control. A 50% reduction in settling time and 70% decrease in power angle undershoots at the slack bus are achieved following disturbances, even at minimum wind penetration levels. Load flow analysis shows the coordinated controllers maintain voltages within 0.5% of nominal at 60% wind penetration, while voltages at load buses can deviate up to 15% without control. Eigenvalue analysis indicates the PSS-STATCOM boosts damping ratios of critical oscillatory modes from nearly 0% to over 30% under high wind injection. Together, the present findings provide significant evidence that PSS and STATCOM cooperation enhances dynamic voltage regulation, angle stability, and damping across operating ranges, thereby maintaining secure operation in systems with high renewable integration.


  • Open Access

    Novel strategy for fault e-diagnosis of wind energy conversion systems using wavelet analysis based on Rt-Lab and Arduino

    by Ahmed Cheriet, Abdeldjebar Hazzab, Abdelkader Bekri, Hicham Gouabi, Mohamed Habbab, Miloud Rezkallah, Ambrish Chandra, Hussein Ibrahim

    The diagnosis of wind energy conversion systems (WECS) turns out to be necessary because of their relatively high cost of operation and maintenance. Wind turbines are hard-to-access structures, and they are often located in remote areas. Therefore, a remote diagnosis (e-diagnosis) is required. This paper proposes an alternative approach for the e-diagnosis of a WECS based on the discrete wavelet transform (DWT) and frequency analysis of the aero generator stator currents. To validate this approach, real-time hardware in the loop (HIL) is used to simulate in real-time the mathematical model of the induction generator on the OPAL-RT OP5600 platform to generate the stator currents and the rotor speed. The DWT is applied to the current signal, to generate the DWT signal, which has a huge number of points that are not supported for direct transmission by the Arduino Mega RobotDyn because of its limited sample time. The absolute values of the DWT peak points (MDWT) are sent as point’s packages form to the diagnosis station via the ESP8266 integrated Wi-Fi board of the Arduino Mega RobotDyn to monitor the SCIG states and determine the number of broken bars.