DVDustin Valdez

Dustin Valdez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dustin Valdez has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Data from Ethnic Mixture and Body Mass Index as Modifiers of Breast Cancer Risk among Native Hawaiian Women: Insights from the Multiethnic Cohort

    by Dustin Valdez, Janine V. Abe, Patricia Bohmann, David Bogumil, Lynne R. Wilkens, Loïc Le Marchand, Christopher A. Haiman, John A. Shepherd, Gertraud Maskarinec

    Background:Native Hawaiian (NH) women experience high breast cancer incidence and mortality. Although obesity is a known risk factor, the role of ethnic mixture, defined as self-reported combinations of racial or ethnic backgrounds, remains understudied. This population-based study examined whether breast cancer risk varies by ethnic mixture among NH women and whether these associations differ across body mass index (BMI) categories.Methods:We analyzed data from 7,700 NH women in the Multiethnic Cohort Study. Participants were categorized into ethnic mixture groups as NH only, NH/White, NH/Chinese, NH/White/Chinese, NH/other Asian, and NH/other. Age-adjusted incidence rates were calculated per 1,000 person-years. Cox proportional hazards models estimated hazard ratios (HR) and 95% confidence intervals (CI), adjusting for age, BMI, and other factors.Results:Incidence rates were highest among NH only and NH/White/Chinese (5.7 and 5.9 per 1,000 person-years) and lowest among NH/other (3.6). However, ethnic mixture was not significantly associated with risk in adjusted models. Stratified analyses showed modest, nonsignificant risk elevations among overweight NH/Chinese (HR = 1.33; 95% CI, 0.85–2.10). Among obese women, risk was consistent across all groups (HRs: 0.78–0.96), highlighting the dominant role of BMI. Overall, the association between ethnic mixture and breast cancer risk did not differ by BMI category.Conclusions:Ethnic mixture was not independently associated with breast cancer risk; BMI remained a consistent predictor. These findings underscore the need for research integrating ancestry, body composition, and social context to address cancer disparities.Impact:Obesity, not ethnic mixture, is the dominant factor influencing breast cancer risk in NH women.

  • Open Access

    Table S1 from Ethnic Mixture and Body Mass Index as Modifiers of Breast Cancer Risk among Native Hawaiian Women: Insights from the Multiethnic Cohort

    by Dustin Valdez, Janine V. Abe, Patricia Bohmann, David Bogumil, Lynne R. Wilkens, Loïc Le Marchand, Christopher A. Haiman, John A. Shepherd, Gertraud Maskarinec

    Table S1 showing HR and 95% CI for breast cancer and BMI

  • Ethnic Mixture and Body Mass Index as Modifiers of Breast Cancer Risk among Native Hawaiian Women: Insights from the Multiethnic Cohort

    by Dustin Valdez, Janine V. Abe, Patricia Bohmann, David Bogumil, Lynne R. Wilkens, Loïc Le Marchand, Christopher A. Haiman, John A. Shepherd, Gertraud Maskarinec

    Background: Native Hawaiian (NH) women experience high breast cancer incidence and mortality. Although obesity is a known risk factor, the role of ethnic mixture, defined as self-reported combinations of racial or ethnic backgrounds, remains understudied. This population-based study examined whether breast cancer risk varies by ethnic mixture among NH women and whether these associations differ across body mass index (BMI) categories. Methods: We analyzed data from 7,700 NH women in the Multiethnic Cohort Study. Participants were categorized into ethnic mixture groups as NH only, NH/White, NH/Chinese, NH/White/Chinese, NH/other Asian, and NH/other. Age-adjusted incidence rates were calculated per 1,000 person-years. Cox proportional hazards models estimated hazard ratios (HR) and 95% confidence intervals (CI), adjusting for age, BMI, and other factors. Results: Incidence rates were highest among NH only and NH/White/Chinese (5.7 and 5.9 per 1,000 person-years) and lowest among NH/other (3.6). However, ethnic mixture was not significantly associated with risk in adjusted models. Stratified analyses showed modest, nonsignificant risk elevations among overweight NH/Chinese (HR = 1.33; 95% CI, 0.85–2.10). Among obese women, risk was consistent across all groups (HRs: 0.78–0.96), highlighting the dominant role of BMI. Overall, the association between ethnic mixture and breast cancer risk did not differ by BMI category. Conclusions: Ethnic mixture was not independently associated with breast cancer risk; BMI remained a consistent predictor. These findings underscore the need for research integrating ancestry, body composition, and social context to address cancer disparities. Impact: Obesity, not ethnic mixture, is the dominant factor influencing breast cancer risk in NH women.

  • Learning a Clinically-Relevant Concept Bottleneck for Lesion Detection in Breast Ultrasound

    by Arianna Bunnell, Yannik Glaser, Dustin Valdez, Thomas Wolfgruber, Aleen Altamirano, Carol Zamora González, Brenda Y. Hernandez, Peter Sadowski, John A. Shepherd


  • Open Access

    Performance of progressive generations of GPT on an exam designed for certifying physicians as Certified Clinical Densitometrists

    by Dustin Valdez, Arianna Bunnell, Sian Yik Lim, Peter Sadowski, John A. Shepherd

    Background: Artificial intelligence (AI) large language models (LLMs) such as ChatGPT have demonstrated the ability to pass standardized exams. These models are not trained for a specific task, but instead trained to predict sequences of text from large corpora of documents sourced from the internet. It has been shown that even models trained on this general task can pass exams in a variety of domain-specific fields, including the United States Medical Licensing Examination. We asked if LLMs would perform as well on a much narrower subdomain tests designed for medical specialists. Furthermore, we wanted to better understand how progressive generations of GPT (generative pre-trained transformer) models may be evolving in the completeness and sophistication of their responses even while generational training remains general. In this study, we evaluated the performance of two versions of GPT (GPT 3 and 4) on their ability to pass the certification exam given to physicians to work as osteoporosis specialists and become a certified clinical densitometrists. Methods: A 100-question multiple-choice practice exam was obtained from a 3 rd party exam preparation website that mimics the accredited certification tests given by the ISCD (international society for clinical densitometry). The exam was administered to two versions of GPT, the free version (GPT Playground) and ChatGPT+, which are based on GPT-3 and GPT-4, respectively (OpenAI, San Francisco, CA). The systems were prompted with the exam questions verbatim. If the response was purely textual and did not specify which of the multiple-choice answers to select, the authors matched the text to the closest answer. Each exam was graded and an estimated ISCD score was provided from the exam website. In addition, each response was evaluated by a rheumatologist CCD and ranked for accuracy using a 5-level scale. The two GPT versions were compared in terms of response accuracy and length. Results: The average response length was 11.6 ±19 words for GPT-3 and 50.0±43.6 words for GPT-4. GPT-3 answered 62 questions correctly resulting in a failing ISCD score of 289. However, GPT-4 answered 82 questions correctly with a passing score of 342. GPT-3 scored highest on the “Overview of Low Bone Mass and Osteoporosis” category (72% correct) while GPT-4 scored well above 80% accuracy on all categories except “Imaging Technology in Bone Health” (65% correct). Regarding subjective accuracy, GPT-3 answered 23 questions with nonsensical or totally wrong responses while GPT-4 had no responses in that category. Conclusion: If this had been an actual certification exam, GPT-4 would now have a CCD suffix to its name even after being trained using general internet knowledge. Clearly, more goes into physician training than can be captured in this exam. However, GPT algorithms may prove to be valuable physician aids in the diagnoses and monitoring of osteoporosis and other diseases.


  • Open Access

    Performance of progressive generations of GPT on an exam designed for certifying physicians as Certified Clinical Densitometrists (Preprint)

    by Dustin Valdez, Arianna Bunnell, Sian Yik Lim, Peter Sadowski, John Shepherd

    BACKGROUND Artificial intelligence (AI) large language models (LLMs) such as ChatGPT have demonstrated the ability to pass standardized exams. These models are not trained for a specific task, but instead trained to predict sequences of text from large corpora of documents sourced from the internet. It has been shown that even models trained on this general task can pass exams in a variety of domain-specific fields, including the United States Medical Licensing Examination. We asked if LLMs would perform as well on a much narrower subdomain tests designed for medical specialists. Furthermore, we wanted to better understand how progressive generations of GPT (generative pre-trained transformer) models may be evolving in the completeness and sophistication of their responses even while generational training remains general. OBJECTIVE To evaluate the performance of two versions of GPT (GPT 3 and 4) on their ability to pass the certification exam given to physicians to work as osteoporosis specialists and become a certified clinical densitometrists. METHODS A 100-question multiple-choice practice exam was obtained from a 3rd party exam preparation website that mimics the accredited certification tests given by the ISCD (international society for clinical densitometry). The exam was administered to two versions of GPT, the free version (GPT Playground) and ChatGPT+, which are based on GPT-3 and GPT-4, respectively (OpenAI, San Francisco, CA). The systems were prompted with the exam questions verbatim. If the response was purely textual and did not specify which of the multiple-choice answers to select, the authors matched the text to the closest answer. Each exam was graded and an estimated ISCD score was provided from the exam website. In addition, each response was evaluated by a rheumatologist CCD and ranked for accuracy using a 5-level scale. The two GPT versions were compared in terms of response accuracy and length. RESULTS The average response length was 11.6 ±19 words for GPT-3 and 50.0±43.6 words for GPT-4. GPT-3 answered 62 questions correctly resulting in a failing ISCD score of 289. However, GPT-4 answered 82 questions correctly with a passing score of 342. GPT-3 scored highest on the “Overview of Low Bone Mass and Osteoporosis” category (72% correct) while GPT-4 scored well above 80% accuracy on all categories except “Imaging Technology in Bone Health” (65% correct). Regarding subjective accuracy, GPT-3 answered 23 questions with nonsensical or totally wrong responses while GPT-4 had no responses in that category. CONCLUSIONS If this had been an actual certification exam, GPT-4 would now have a CCD suffix to its name even after being trained using general internet knowledge. Clearly, more goes into physician training than can be captured in this exam. However, GPT algorithms may prove to be valuable physician aids in the diagnoses and monitoring of osteoporosis and other diseases.

  • Technical note: Low clinical efficacy, but good acceptability of a point‐of‐care electronic palpation device for breast cancer screening for a lower middle‐income environment

    by Dustin Valdez, Teofila Cruz, Stephanie Rania, Grazyna Badowski, Kevin Cassel, Thomas Wolfgruber, Scott Grosskreutz, Louis J. Dulana, Roy Adonay, Gertraud Maskarinec, et al.

    Background : Late-stage breast cancer rates in the Pacific where mammography services are limited are exceedingly high: Marshall Islands (61%), Palau (94%), and Samoa (79%). Due to the limited medical resources in these areas an alternative accessible technology is needed. The iBreast Exam (iBE) is a point-of-care electronic palpitation device that has a reported sensitivity of 86%. However, little is known about the performance and acceptability of this device for women in the Pacific. Methods : A total of 39 women (ages 42–73 years) were recruited in Guam with 19 women having a mammogram requiring biopsy (BI-RADS category 4 or above) and 20 women with a negative screening mammogram before study visit. Participants received an iBE exam and completed a 26-item breast health questionnaire to evaluate the iBE. Furthermore, the performance characteristics of the iBE were tested using gelatin breast phantoms in terms of tumor size, tumor depth, and overall breast stiffness. Results : The iBE had a sensitivity of 20% (2 true positives to 8 false negatives) and specificity of 92% (24 false positives to 278 true negatives) when analyzed based on location of tumor by quadrant. The iBE also had generally poor agreement according to a Cohen's kappa value of 0.068. The phantom experiments showed that the iBE can detect tumors as deep as 2.5cm, but only if the lesion is greater than 8mm in diameter. However, the iBE did demonstrate acceptability; 67% of the women reported that they had high trust in iBE as an early detection device. Conclusions : The iBE had generally poor sensitivity and specificity when tested in a clinical setting which does not allow its use as a screening tool. Impact : This study demonstrates the need for an alternative screening method other than electronic palpation for lower-middle income areas. This article is protected by copyright. All rights reserved