Jiameng Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiameng Tian has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Bin Chen
State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, China
6 shared publications - Junfeng Wang
School of Energy and Power Engineering, Jiangsu University 1 , Zhenjiang, Jiangsu 212013
6 shared publications Junfeng Wang
School of Energy and Power Engineering Jiangsu University Zhenjiang China
4 shared publications- Mohamed Qenawy
School of Energy and Power Engineering, Jiangsu University 1 , Zhenjiang 212013, China
4 shared publications Yiqi Chen
4 shared publications- Zhentao Wang
School of Energy and Power Engineering, Jiangsu University 1 , Zhenjiang, Jiangsu 212013
4 shared publications
Latest Publications
- 6 August 2026
- Published by Wiley in AIChE Journal
- Vol. 72 (11) , e70582
Coupling of plasma discharge, bubble dynamics, and CO 2 conversion in a gas–liquid dielectric barrier discharge reactor
Plasma‐assisted carbon dioxide (CO 2 ) conversion in gas–liquid systems provides a potential pathway for carbon utilization under ambient conditions, yet its performance is often constrained by gas–liquid transport. This work investigates CO 2 conversion in a water‐filled dielectric barrier discharge (DBD) reactor by correlating discharge characteristics, bubble dispersion pattern, and conversion performance. High‐speed visualization reveals that the plasma discharge suppresses bubble coalescence and promotes breakup, shifting the bubble size distribution from a coarse unimodal population to a finer and more dispersed pattern. This transition is accompanied by increased bubble number density, enhanced interfacial renewal, and stronger bubble‐induced flows, thereby intensifying gas–liquid mass transfer. Correspondingly, the apparent gas‐phase CO 2 removal index reaches approximately 30% at low gas flow rates but decreases markedly with increasing flow rate, where hydrodynamic effects become dominant. The results suggest that conversion in gas–liquid DBD systems is closely associated with plasma‐modified bubble dynamics, providing mechanistic guidance for optimizing plasma‐assisted CO 2 conversion processes.
- 6 August 2026
- Published by Wiley in AIChE Journal
- Vol. 72 (11) , e70582
Coupling of plasma discharge, bubble dynamics, and CO 2 conversion in a gas–liquid dielectric barrier discharge reactor
Plasma‐assisted carbon dioxide (CO 2 ) conversion in gas–liquid systems provides a potential pathway for carbon utilization under ambient conditions, yet its performance is often constrained by gas–liquid transport. This work investigates CO 2 conversion in a water‐filled dielectric barrier discharge (DBD) reactor by correlating discharge characteristics, bubble dispersion pattern, and conversion performance. High‐speed visualization reveals that the plasma discharge suppresses bubble coalescence and promotes breakup, shifting the bubble size distribution from a coarse unimodal population to a finer and more dispersed pattern. This transition is accompanied by increased bubble number density, enhanced interfacial renewal, and stronger bubble‐induced flows, thereby intensifying gas–liquid mass transfer. Correspondingly, the apparent gas‐phase CO 2 removal index reaches approximately 30% at low gas flow rates but decreases markedly with increasing flow rate, where hydrodynamic effects become dominant. The results suggest that conversion in gas–liquid DBD systems is closely associated with plasma‐modified bubble dynamics, providing mechanistic guidance for optimizing plasma‐assisted CO 2 conversion processes.
- 20 November 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 284
Spatio-temporal variation of spray flash evaporation and its impact on surface heat transfer
- 20 November 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 284
Spatio-temporal variation of spray flash evaporation and its impact on surface heat transfer
- 19 November 2025
- Published by Elsevier in Carbohydrate Polymers
- Vol. 375, 124693
Eco-friendly nanocellulose composites for stabilizing nanoemulsion insecticides: Enhancing efficacy and weather resistance
- 19 November 2025
- Published by Elsevier in Carbohydrate Polymers
- Vol. 375, 124693
Eco-friendly nanocellulose composites for stabilizing nanoemulsion insecticides: Enhancing efficacy and weather resistance
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
An experimental study on two-phase flashing R134a spray cooling performance with multiple nozzles
Low-boiling-point R134a spray cooling effectively reduces surface temperatures rapidly, with applications in chip cooling, automotive air conditioning, and laser biomedicine. Multiple nozzles have a larger spray coverage and liquid film spreading area compared to a single nozzle, allowing for enhanced convective and phase-change heat transfer, leading to large-area uniform cooling and flexible adjustment of cooling capacity. An experimental apparatus for cryogen spray cooling was set up to analyze the effects of various factors, including nozzle inner diameter, spray distance, spray pressure, spurt duration, and cooling substrate, on the surface heat transfer characteristics. The results indicate that the lowest surface temperature is primarily influenced by the nozzle inner diameter and spray distance, while the peak heat flux is mainly affected by the spray distance and the cooling substrate. The heat flux with copper surface is ∼38 times that of an epoxy resin block (qmax = 8179.94 kW/m2). Nozzle diameter has the most significant impact on the uniformity of surface cooling, whereas spray pressure and duration have the weakest effects on surface heat transfer characteristics. When the cooling substrate is an epoxy resin block, appropriate spray conditions (Nozzle diameter D = 0.4 mm, spray pressure P = 1.9 MPa, spray distance H = 10 mm, and spurt duration ts= 50 ms) allow droplets to fully atomize and distribute reasonably across the surface, achieving the lowest cooling temperature (Tmin = −40.13 °C) and the highest heat flux (qmax = 217.76 kW/m2) as well as realizing a longer effective cooling time.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
An experimental study on two-phase flashing R134a spray cooling performance with multiple nozzles
Low-boiling-point R134a spray cooling effectively reduces surface temperatures rapidly, with applications in chip cooling, automotive air conditioning, and laser biomedicine. Multiple nozzles have a larger spray coverage and liquid film spreading area compared to a single nozzle, allowing for enhanced convective and phase-change heat transfer, leading to large-area uniform cooling and flexible adjustment of cooling capacity. An experimental apparatus for cryogen spray cooling was set up to analyze the effects of various factors, including nozzle inner diameter, spray distance, spray pressure, spurt duration, and cooling substrate, on the surface heat transfer characteristics. The results indicate that the lowest surface temperature is primarily influenced by the nozzle inner diameter and spray distance, while the peak heat flux is mainly affected by the spray distance and the cooling substrate. The heat flux with copper surface is ∼38 times that of an epoxy resin block (qmax = 8179.94 kW/m2). Nozzle diameter has the most significant impact on the uniformity of surface cooling, whereas spray pressure and duration have the weakest effects on surface heat transfer characteristics. When the cooling substrate is an epoxy resin block, appropriate spray conditions (Nozzle diameter D = 0.4 mm, spray pressure P = 1.9 MPa, spray distance H = 10 mm, and spurt duration ts= 50 ms) allow droplets to fully atomize and distribute reasonably across the surface, achieving the lowest cooling temperature (Tmin = −40.13 °C) and the highest heat flux (qmax = 217.76 kW/m2) as well as realizing a longer effective cooling time.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Cone-jet regime in electrospray: A comprehensive review
Cone jet is a very important and promising mean in electrohydrodynamic atomization or electrospray, where a liquid cone forms at the end of a capillary tube at a rational range of potential and flow rate and a permanent, stable, and thin jet emerges from the cone tip and further disintegrates into plenty of fine drops. Owing to several advantages of uniform and microscale drop size, high-charge density, and precise trajectory control, the cone-jet electrospray effectively meets a wide range of application requirements. This work provides a critical review the recent experiments, theories, analysis, and numerical simulations concerning the formation and evolution of Taylor cone and cone jet, as well as the subsequent jet breakup and drops generation. Our aim is to offer a comprehensive understanding of the underlying physics of the process of cone jet, including the conditions for the formation and the stable operation of the cone jet, and the universal scaling laws governing minimum flow rate, drop size, and electric current, as well as the instability of cone jet. In addition, the coaxial Taylor cone jets and the recent numerical studies on cone-jet dynamics are also briefly reviewed.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Cone-jet regime in electrospray: A comprehensive review
Cone jet is a very important and promising mean in electrohydrodynamic atomization or electrospray, where a liquid cone forms at the end of a capillary tube at a rational range of potential and flow rate and a permanent, stable, and thin jet emerges from the cone tip and further disintegrates into plenty of fine drops. Owing to several advantages of uniform and microscale drop size, high-charge density, and precise trajectory control, the cone-jet electrospray effectively meets a wide range of application requirements. This work provides a critical review the recent experiments, theories, analysis, and numerical simulations concerning the formation and evolution of Taylor cone and cone jet, as well as the subsequent jet breakup and drops generation. Our aim is to offer a comprehensive understanding of the underlying physics of the process of cone jet, including the conditions for the formation and the stable operation of the cone jet, and the universal scaling laws governing minimum flow rate, drop size, and electric current, as well as the instability of cone jet. In addition, the coaxial Taylor cone jets and the recent numerical studies on cone-jet dynamics are also briefly reviewed.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
A comprehensive study of interpolation methods in electrohydrodynamic cone-jet across diverse liquid conductivities
Accurate modeling of electrohydrodynamic atomization (EHDA) in the cone-jet regime requires reliable interpolation of fluid properties—such as permittivity, conductivity, and viscosity—across the liquid–gas interface. While the weighted arithmetic mean (WAM) is widely used in two-phase simulations due to its simplicity and stability, it may introduce significant inaccuracies in electrohydrodynamic (EHD) applications by over-smoothing critical property gradients. This study presents a comprehensive comparative analysis of five mean interpolation methods—weighted arithmetic mean (WAM), weighted harmonic mean (WHM), geometric mean (GM), modified geometric mean (mGM), and power-law mean (PLM)—for modeling electrohydrodynamic atomization (EHDA) processes under varying conductivity regimes. By evaluating their performance on key EHD metrics such as surface charge distribution, cone-jet dynamics, droplet size, jet breakup, and beam current, we reveal the strengths and limitations of each method. Numerical results were validated against experimental data and established scaling laws. For low-conductivity fluids, WAM demonstrated superior accuracy in predicting droplet sizes and beam currents due to its balanced interpolation and numerical robustness, while WHM offered stronger charge retention at the expense of stability. GM, mGM, and PLM provided improved physical accuracy under conditions of assured numerical stability. In the medium-conductivity regime, WHM emerged as the most effective method for capturing interfacial charge dynamics and droplet formation, although WAM excelled in predicting geometric features such as jet length and Taylor-cone height. For high-conductivity fluids, all five interpolation schemes yielded comparable results, accurately estimating droplet sizes and beam currents within a 5% margin of experimental values. The findings underscore the importance of selecting appropriate interpolation methods based on fluid conductivity, with WAM favored for low-conductivity fluids, WHM for medium-conductivity systems, and flexibility among all schemes for high-conductivity scenarios. These findings provide practical guidance for selecting or tuning interpolation methods in two-phase EHD simulations and establish a robust framework for improving numerical reliability in multiphase electrohydrodynamic modeling.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
A comprehensive study of interpolation methods in electrohydrodynamic cone-jet across diverse liquid conductivities
Accurate modeling of electrohydrodynamic atomization (EHDA) in the cone-jet regime requires reliable interpolation of fluid properties—such as permittivity, conductivity, and viscosity—across the liquid–gas interface. While the weighted arithmetic mean (WAM) is widely used in two-phase simulations due to its simplicity and stability, it may introduce significant inaccuracies in electrohydrodynamic (EHD) applications by over-smoothing critical property gradients. This study presents a comprehensive comparative analysis of five mean interpolation methods—weighted arithmetic mean (WAM), weighted harmonic mean (WHM), geometric mean (GM), modified geometric mean (mGM), and power-law mean (PLM)—for modeling electrohydrodynamic atomization (EHDA) processes under varying conductivity regimes. By evaluating their performance on key EHD metrics such as surface charge distribution, cone-jet dynamics, droplet size, jet breakup, and beam current, we reveal the strengths and limitations of each method. Numerical results were validated against experimental data and established scaling laws. For low-conductivity fluids, WAM demonstrated superior accuracy in predicting droplet sizes and beam currents due to its balanced interpolation and numerical robustness, while WHM offered stronger charge retention at the expense of stability. GM, mGM, and PLM provided improved physical accuracy under conditions of assured numerical stability. In the medium-conductivity regime, WHM emerged as the most effective method for capturing interfacial charge dynamics and droplet formation, although WAM excelled in predicting geometric features such as jet length and Taylor-cone height. For high-conductivity fluids, all five interpolation schemes yielded comparable results, accurately estimating droplet sizes and beam currents within a 5% margin of experimental values. The findings underscore the importance of selecting appropriate interpolation methods based on fluid conductivity, with WAM favored for low-conductivity fluids, WHM for medium-conductivity systems, and flexibility among all schemes for high-conductivity scenarios. These findings provide practical guidance for selecting or tuning interpolation methods in two-phase EHD simulations and establish a robust framework for improving numerical reliability in multiphase electrohydrodynamic modeling.
- 15 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Enhancing flashing spray cooling with eco-friendly R1234yf through intermittent spurt coupled with cold air jet
- 15 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Enhancing flashing spray cooling with eco-friendly R1234yf through intermittent spurt coupled with cold air jet
- Open Access
- 1 April 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (4)
Improving fluid flow and heat transfer of cryogen spray cooling using sweeping cold air jet
Industrial growth has led to increased electronic component integration, resulting in higher working temperatures and technological failures. Cryogen spray cooling (CSC) could reach cryogenic temperatures with fast-responding, but its heat transfer limitation due to liquid film deposition is potentially challenging. In this study, CSC cooling is incorporated with either a cold air jet (CAJ) or a sweeping jet (SWJ) to enhance heat and fluid flow. A K-type thermocouple is used for measuring the surface temperature, while the improved Duhamel theorem is used to estimate the heat flux. The spray and film intensities are recorded through the Mie-scattering methodology via high-speed camera. The results demonstrated that the CAJ/SWJ exhibited a significant reduction in surface temperature and film intensity, enhanced heat dissipation and spray efficiency compared to CSC cooling. More precisely, it demonstrated a 26%–36% heat transfer coefficient improvement, along with a 52% increase in the corresponding time of the critical heat flux. Meanwhile, the CAJ/SWJ intensifies heat transfer during film and transition boiling, inspired by the fast liquid film evaporations. In contrast, the SWJ is much preferred due to its wider and stable coolant coverage throughout film evaporation, as seen by its greater heat transfer coefficient. The combined results demonstrated the need to promptly eliminate the deposited film, as it holds the potential to serve as a pivotal resolution for the advancement of thermal management technology.
- 1 April 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (4)
Open AccessImproving fluid flow and heat transfer of cryogen spray cooling using sweeping cold air jet
Industrial growth has led to increased electronic component integration, resulting in higher working temperatures and technological failures. Cryogen spray cooling (CSC) could reach cryogenic temperatures with fast-responding, but its heat transfer limitation due to liquid film deposition is potentially challenging. In this study, CSC cooling is incorporated with either a cold air jet (CAJ) or a sweeping jet (SWJ) to enhance heat and fluid flow. A K-type thermocouple is used for measuring the surface temperature, while the improved Duhamel theorem is used to estimate the heat flux. The spray and film intensities are recorded through the Mie-scattering methodology via high-speed camera. The results demonstrated that the CAJ/SWJ exhibited a significant reduction in surface temperature and film intensity, enhanced heat dissipation and spray efficiency compared to CSC cooling. More precisely, it demonstrated a 26%–36% heat transfer coefficient improvement, along with a 52% increase in the corresponding time of the critical heat flux. Meanwhile, the CAJ/SWJ intensifies heat transfer during film and transition boiling, inspired by the fast liquid film evaporations. In contrast, the SWJ is much preferred due to its wider and stable coolant coverage throughout film evaporation, as seen by its greater heat transfer coefficient. The combined results demonstrated the need to promptly eliminate the deposited film, as it holds the potential to serve as a pivotal resolution for the advancement of thermal management technology.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Intermittent cryogen spray cooling coupled with cold air jet for heat transfer enhancement and cryogen saving of laser dermatology
Laser dermatology has become a convenient technique for medical treatment. However, the epidermal temperature could be increased, leading to intolerable side effects. Cryogen spray cooling (CSC) is implemented to decrease epidermal damage, but the current CSC could increase cryogen wastage. In this study, the CSC is coupled with a cold air jet (CAJ) and is further subjected to intermittent strategy (ICSC) to mitigate film deposition, enhance heat transfer, and save cryogen consumption, through CAJ-to-spray interaction. The surface temperature is measured by a thin film type-T thermocouple, while the heat transfer is estimated by enhanced Duhamel theorem. The film intensity is captured by a digital single-lens reflex camera through the scattering-illumination technique. The results affirmed the benefits of using ICSC/ICSC-CAJ for laser dermatology. It demonstrated lower surface temperature, film intensity, and film resistance as well as higher convection and efficiency compared with CSC. ICSC-CAJ showed the lowest minimum temperature (1.8%–4.9% decrement) and film resistance (3.8%–17.5% decrement), the highest average convective coefficient (84%–92% increment) and efficiency (7%–9% increment) compared with ICSC. Lower frequency and moderate duties would be preferable for ICSC, while higher frequency and lower duties would be preferable for ICSC-CAJ. The efficiency increased with the saving (110% increment), which insights into our understanding of alternative enhancement toward cryogen saving strategy.
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Open AccessIntermittent cryogen spray cooling coupled with cold air jet for heat transfer enhancement and cryogen saving of laser dermatology
Laser dermatology has become a convenient technique for medical treatment. However, the epidermal temperature could be increased, leading to intolerable side effects. Cryogen spray cooling (CSC) is implemented to decrease epidermal damage, but the current CSC could increase cryogen wastage. In this study, the CSC is coupled with a cold air jet (CAJ) and is further subjected to intermittent strategy (ICSC) to mitigate film deposition, enhance heat transfer, and save cryogen consumption, through CAJ-to-spray interaction. The surface temperature is measured by a thin film type-T thermocouple, while the heat transfer is estimated by enhanced Duhamel theorem. The film intensity is captured by a digital single-lens reflex camera through the scattering-illumination technique. The results affirmed the benefits of using ICSC/ICSC-CAJ for laser dermatology. It demonstrated lower surface temperature, film intensity, and film resistance as well as higher convection and efficiency compared with CSC. ICSC-CAJ showed the lowest minimum temperature (1.8%–4.9% decrement) and film resistance (3.8%–17.5% decrement), the highest average convective coefficient (84%–92% increment) and efficiency (7%–9% increment) compared with ICSC. Lower frequency and moderate duties would be preferable for ICSC, while higher frequency and lower duties would be preferable for ICSC-CAJ. The efficiency increased with the saving (110% increment), which insights into our understanding of alternative enhancement toward cryogen saving strategy.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (12)
Unstable spray pattern and cooling performance of cryogen spray coupled with cold air jet: An experimental study
This study focuses on the interactions between cryogen spray cooling (CSC) and cold air jet (CAJ), as well as the heat transfer performance upon CAJ-CSC impingement assisted for laser dermatology. CAJ is found to collapse downstream spray on the windward side, enhancing fluctuations of R1234yf spray width. Standard deviation (SD) distribution identifies that fluctuations at nozzle exit are attributed to ambient-to-spray interactions, which is also confirmed by the proper orthogonal decomposition (POD) analysis. The third POD mode highlights jet-to-spray interactions on the windward side of spray, yielding an enhanced instability by 1.72 times when CAJ flow rate (Q) increases from 4 to 8 m3/h. The closer location to the spray center on the same radial side corresponds to a faster thermal response and a lower temperature drop (ΔT). ΔT on the windward side decreases due to the considerable CAJ-induced droplet swarm drift. The heat transfer degrades on the leeward side due to the thermal gas boundary layer originating from the inclined CAJ sweep. Nevertheless, the CAJ with a small flow rate (4 m3/h) enhances the heat transfer at spray center, yielding a minimum surface temperature of −32.3 °C. Comparative investigation indicates R134a has superior cooling performance but more significant instabilities inside spray plume. R1234yf serves a relatively stable sub-cooling region within a radial distance of ±1 mm from spray center characterized by low spray fluctuations and high temperature drops at Q = 4 m3/h. Substitution of R1234yf for R134a still needs heat transfer enhancement for clinical considerations.
- 1 December 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (12)
Open AccessUnstable spray pattern and cooling performance of cryogen spray coupled with cold air jet: An experimental study
This study focuses on the interactions between cryogen spray cooling (CSC) and cold air jet (CAJ), as well as the heat transfer performance upon CAJ-CSC impingement assisted for laser dermatology. CAJ is found to collapse downstream spray on the windward side, enhancing fluctuations of R1234yf spray width. Standard deviation (SD) distribution identifies that fluctuations at nozzle exit are attributed to ambient-to-spray interactions, which is also confirmed by the proper orthogonal decomposition (POD) analysis. The third POD mode highlights jet-to-spray interactions on the windward side of spray, yielding an enhanced instability by 1.72 times when CAJ flow rate (Q) increases from 4 to 8 m3/h. The closer location to the spray center on the same radial side corresponds to a faster thermal response and a lower temperature drop (ΔT). ΔT on the windward side decreases due to the considerable CAJ-induced droplet swarm drift. The heat transfer degrades on the leeward side due to the thermal gas boundary layer originating from the inclined CAJ sweep. Nevertheless, the CAJ with a small flow rate (4 m3/h) enhances the heat transfer at spray center, yielding a minimum surface temperature of −32.3 °C. Comparative investigation indicates R134a has superior cooling performance but more significant instabilities inside spray plume. R1234yf serves a relatively stable sub-cooling region within a radial distance of ±1 mm from spray center characterized by low spray fluctuations and high temperature drops at Q = 4 m3/h. Substitution of R1234yf for R134a still needs heat transfer enhancement for clinical considerations.