Ravi Shankar Tiwari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ravi Shankar Tiwari has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Om Hari Gupta
Electrical Engineering, National Institute of Technology Jamshedpur, Jamshedpur, India
3 shared publications Om Hari Gupta
Department of Electrical Engineering, National Institute of Technology
2 shared publicationsVijay K. Sood
Department of Electrical, Computer and Software Engineering, Ontario Tech University
2 shared publications- Anjali Gupta
GLA University
1 shared publication Lingqi He
College of Electrical and Information Engineering, Hunan University 3 , Changsha 410082
1 shared publicationMayank Goyal
Department of Electrical Engineering GLA University
1 shared publication
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 123-135
Renewable Energy Sources: State of the Art and Technical Viability to Fulfil the Energy Demand of Society: A Review
- 2 August 2026
- Published by Springer Nature
- p. 123-135
Renewable Energy Sources: State of the Art and Technical Viability to Fulfil the Energy Demand of Society: A Review
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
A six-year continuous performance review of a grid-connected solar photovoltaic (GSPV) plant with baseline simulated benchmarking via PVsyst
This paper presents a longitudinal performance evaluation of a rooftop grid-connected solar photovoltaic (GSPV) plant, emphasizing alterations in energy production and performance ratio (PR) over time. The assessment involves year-wise data analysis for 6 years of a 1.39 MW GSPV plant in north India. The purpose is to assess performance, degradation trends in energy production, system losses, and capability under varying climatic conditions. The key indicators critically examined to quantify plant performance are energy production, PR, capacity factor, yield factors, losses, and rate of degradation of the plant. The total energy production received in 6 years is 8887.91 MWh. The average annual reference yield, array yield, and final yield are 4.47, 3.09, and 2.29, respectively. In order to create a technical benchmark, the plant is modeled in PVsyst software and analyzed annually using site-specific meteorological and system configuration data. The simulated results are compared with the real-time measured data of the plant obtained from the metering and recording unit to confirm the reliability and accuracy of the simulation-based performance prediction. At the end, the percentage error (% ξ) and mean average percentage errors (MAPE) between real-time and simulated results are evaluated. The MAPE is small, less than 5% for the initial year, which increased in subsequent years due to inadequate assumptions in factors like soiling, thermal losses, component ageing, etc. This study highlights the factors that essentially affect the accuracy of the static baseline model for long-term performance prediction.
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
A six-year continuous performance review of a grid-connected solar photovoltaic (GSPV) plant with baseline simulated benchmarking via PVsyst
This paper presents a longitudinal performance evaluation of a rooftop grid-connected solar photovoltaic (GSPV) plant, emphasizing alterations in energy production and performance ratio (PR) over time. The assessment involves year-wise data analysis for 6 years of a 1.39 MW GSPV plant in north India. The purpose is to assess performance, degradation trends in energy production, system losses, and capability under varying climatic conditions. The key indicators critically examined to quantify plant performance are energy production, PR, capacity factor, yield factors, losses, and rate of degradation of the plant. The total energy production received in 6 years is 8887.91 MWh. The average annual reference yield, array yield, and final yield are 4.47, 3.09, and 2.29, respectively. In order to create a technical benchmark, the plant is modeled in PVsyst software and analyzed annually using site-specific meteorological and system configuration data. The simulated results are compared with the real-time measured data of the plant obtained from the metering and recording unit to confirm the reliability and accuracy of the simulation-based performance prediction. At the end, the percentage error (% ξ) and mean average percentage errors (MAPE) between real-time and simulated results are evaluated. The MAPE is small, less than 5% for the initial year, which increased in subsequent years due to inadequate assumptions in factors like soiling, thermal losses, component ageing, etc. This study highlights the factors that essentially affect the accuracy of the static baseline model for long-term performance prediction.
- 12 July 2023
- Published by River Publishers in Distributed Generation & Alternative Energy Journal
Dynamic Analysis of VSC-HVDC System with Disturbances in the Adjacent AC Networks
VSC-HVDC systems are widely used to integrate wind farms, asynchronous generations and networks operating at different frequencies. The Multi-terminal (MT) and multi-fed (MF) HVDC’s are the system mainly constituted of VSC’s, to integrate renewable sources and transmitting bulk power to conventional AC grids. A sudden change in the steady state even in adjacent networks may create severe disturbances in the operation of such HVDC systems. The disturbances in AC or DC networks directly influence the performance of systems, particularly in MT-HVDC and MF-HVDC systems. However, the HVDC systems are known for their intelligent control in modulating operational states as and when required. This paper presents the dynamic analysis of MF-HVDC system due to load changes, faults and other disturbances in the adjacent AC networks. The result indicates that VSC-HVDC provides decoupled control of active and reactive power with capability in adjusting operational mode during various minor and major disturbances. Based on the results obtained, the paper proposed a novel sensitivity factor indicating percentage coupling among various line parameters during disturbances. Furthermore, the VSC’s injects harmonic signals on both AC and DC sides of HVDC system. These harmonics voltage or currents signals may get amplified to a dangerously high magnitude at resonance frequencies. Thus, the frequency characteristics of different subsystems are also analyzed using FFT. A ±100 kV, 200 MW bipolar MF VSC-HVDC test systems is used to simulated the results in MATLAB/Simulink software.
- 12 July 2023
- Published by River Publishers in Distributed Generation & Alternative Energy Journal
Dynamic Analysis of VSC-HVDC System with Disturbances in the Adjacent AC Networks
VSC-HVDC systems are widely used to integrate wind farms, asynchronous generations and networks operating at different frequencies. The Multi-terminal (MT) and multi-fed (MF) HVDC’s are the system mainly constituted of VSC’s, to integrate renewable sources and transmitting bulk power to conventional AC grids. A sudden change in the steady state even in adjacent networks may create severe disturbances in the operation of such HVDC systems. The disturbances in AC or DC networks directly influence the performance of systems, particularly in MT-HVDC and MF-HVDC systems. However, the HVDC systems are known for their intelligent control in modulating operational states as and when required. This paper presents the dynamic analysis of MF-HVDC system due to load changes, faults and other disturbances in the adjacent AC networks. The result indicates that VSC-HVDC provides decoupled control of active and reactive power with capability in adjusting operational mode during various minor and major disturbances. Based on the results obtained, the paper proposed a novel sensitivity factor indicating percentage coupling among various line parameters during disturbances. Furthermore, the VSC’s injects harmonic signals on both AC and DC sides of HVDC system. These harmonics voltage or currents signals may get amplified to a dangerously high magnitude at resonance frequencies. Thus, the frequency characteristics of different subsystems are also analyzed using FFT. A ±100 kV, 200 MW bipolar MF VSC-HVDC test systems is used to simulated the results in MATLAB/Simulink software.
- 31 May 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (4) , 4305-4318
Non-unit Protection for Asymmetrical DC Line Faults in Bipolar LCC-HVDC Transmission Systems
- 31 May 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (4) , 4305-4318
Non-unit Protection for Asymmetrical DC Line Faults in Bipolar LCC-HVDC Transmission Systems
- 1 January 2023
- Published by Springer Nature
- p. 217-227
Detection and Classification of Faults in VSC-HVDC System Based on Single End Ground and Pole Differential Current Components
- 1 January 2023
- Published by Springer Nature
- p. 217-227
Detection and Classification of Faults in VSC-HVDC System Based on Single End Ground and Pole Differential Current Components
- 16 October 2020
- Published by Springer Nature
- p. 1-14
Ground Fault Detection Using Pole Differential Current Measurement for 2-Terminal Bipolar HVDC Lines
- 16 October 2020
- Published by Springer Nature
- p. 1-14
Ground Fault Detection Using Pole Differential Current Measurement for 2-Terminal Bipolar HVDC Lines
- 16 October 2020
- Published by Springer Nature
- p. 171-180
HVDC Transmission Topology and Control Analysis
- 16 October 2020
- Published by Springer Nature
- p. 171-180
HVDC Transmission Topology and Control Analysis
- 15 February 2020
- Published by Springer Nature in Springer Proceedings in Mathematics & Statistics
- p. 325-335
Investigation of Transient Stability in IEEE 9-Bus System Using Power World Simulator
- 15 February 2020
- Published by Springer Nature in Springer Proceedings in Mathematics & Statistics
- p. 325-335
Investigation of Transient Stability in IEEE 9-Bus System Using Power World Simulator