PSPaul R. Selvin

Paul R. Selvin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul R. Selvin has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Delivery of Fluorescent Probes Using Streptolysin O for Fluorescence Microscopy of Living Cells

    by Kai Wen Teng, Pin Ren, Paul R. Selvin

    Methods to efficiently deliver fluorophores across the cell membrane are crucial for imaging the dynamics of intracellular proteins using fluorescence. Here we describe a simple protocol for permeabilizing living cells using streptolysin O, a bacterial toxin, which allows transient uptake of fluorescent probes for labeling specific intracellular proteins. The technique is applicable for delivering different classes of fluorescent probes with a molecular weight of <150 kDa, and it is also applicable to a variety of different cell lines. The technique enables the utilization of a broad range of fluorophores for live cell imaging of intracellular proteins. Extended observation of intracellular fluorescence bound to specific proteins is now possible through super‐resolution microscopy by using fluorophores that are photostable in “cell‐friendly” deoxygenating and reducing conditions. © 2018 by John Wiley & Sons, Inc.


  • Two-Photon 3D FIONA of Individual Quantum Dots in an Aqueous Environment

    by Ruobing Zhang, Eli Rothenberg, Gilbert Fruhwirth, Paul D. Simonson, Fangfu Ye, Ido Golding, Tony Ng, Ward Lopes, Paul R. Selvin

    We report the first two-photon (2P) microscopy of individual quantum dots (QDs) in an aqueous environment with both widefield and point-scan excitations at nanometer accuracy. Thiol-containing reductants suppress QD blinking and enable measurement of the 36 nm step size of individual Myosin V motors in vitro. We localize QDs with an accuracy of 2–3 nm in all three dimensions by using a 9 × 9 matrix excitation hologram and an array detector, which also increases the 3D scan imaging rate by 80-fold. With this 3D microscopy we validate the LamB receptor distribution on E. coli and the endocytosis of EGF-receptors in breast cancer cells.


  • Improved Hidden Markov Models for Molecular Motors, Part 2: Extensions and Application to Experimental Data

    by Sheyum Syed, Fiona E. Müllner, Paul R. Selvin, Fred J. Sigworth


  • Reply to Sun et al.: Myosin VI movement: Wiggly or straight?

    by Jeff G. Reifenberger, Erdal Toprak, HyeongJun Kim, Dan Safer, H. Lee Sweeney, Paul R. Selvin

  • Myosin VI undergoes a 180° power stroke implying an uncoupling of the front lever arm

    by Jeff G. Reifenberger, Erdal Toprak, HyeongJun Kim, Dan Safer, H. Lee Sweeney, Paul R. Selvin

    We simultaneously measure both the step size, via FIONA, and the 3-D orientation, via DOPI, of the light-chain domain of individual dimeric myosin VIs. This allows for the correlation of the change in orientation of the light chain domain to the stepping of the motor. Three different pairs of positions were tested using a rigid bifunctional rhodamine on the calmodulin of the IQ domain. The data for all three labeling positions support the model that the light chain domain undergoes a significant rotation of approximately 180°. Contrary to an earlier study [Sun, Y. et al. (2007) Mol Cell 28, 954–964], our data does not support a model of multiple angles of the lever arm of the lead head, nor “wiggly” walking on actin. Instead, we propose that for the two heads of myosin VI to coordinate their processive movement, the lever arm of the lead head must be uncoupled from the converter until the rear head detaches. More specifically, intramolecular strain causes the myosin VI lever arm of the lead head to uncouple from the motor domain, allowing the motor domain to go through its product-release (phosphate and ADP) steps at an unstrained rate. The lever arm of the lead head rebinds to the motor and attains a rigor conformation when the rear head detaches. By coupling the orientation and position information with previously described kinetics, this allows us to explain how myosin VI coordinates its heads processively while maintaining the ability to move under load with a (semi-) rigid lever arm.


  • Why kinesin is so processive

    by Erdal Toprak, Ahmet Yildiz, Melinda Tonks Hoffman, Steven S. Rosenfeld, Paul R. Selvin

    Kinesin I can walk on a microtubule for distances as long as several micrometers. However, it is still unclear how this molecular motor can remain attached to the microtubule through the hundreds of mechanochemical cycles necessary to achieve this remarkable degree of processivity. We have addressed this issue by applying ensemble and single-molecule fluorescence methods to study the process of kinesin stepping, and our results lead to 4 conclusions. First, under physiologic conditions, ≈75% of processively moving kinesin molecules are attached to the microtubule via both heads, and in this conformation, they are resistant to dissociation. Second, the remaining 25% of kinesin molecules, which are in an “ATP waiting state” and are strongly attached to the microtubule via only one head, are intermittently in a conformation that cannot bind ATP and therefore are resistant to nucleotide-induced dissociation. Third, the forward step in the kinesin ATPase cycle is very fast, accounting for <5% of the total cycle time, which ensures that the lifetime of this ATP waiting state is relatively short. Finally, by combining nanometer-level single-molecule fluorescence localization with higher ATP concentrations than used previously, we have determined that in this ATP waiting state, the ADP-containing head of kinesin is located 8 nm behind the attached head, in a location where it can interact with the microtubule lattice. These 4 features reduce the likelihood that a kinesin I motor will dissociate and contribute to making this motor so highly processive.


  • FIONA on Caenorhabditis elegans

    by Comert Kural, Michael L. Nonet, Paul R. Selvin

    Despite much work, subcellular neurons of Caenorhabditis elegans have not been studied at nanometer resolution with millisecond time resolution. Nor has there been an effective way to immobilize C. elegans. Here we show that, without using anesthetic or paralyzing agents, fluorescence imaging with one-nanometer accuracy (FIONA) can be successfully applied to fluorescently labeled molecules within C. elegans nerves. GFP- and DENDRA2-labeled ELKS punctae can be localized with sub-10 nm accuracy in ∼5 ms. Our results show that the protein ELKS is occasionally transferred by microtubule-based motors. This is the first example of FIONA applied to a living organism.


  • The mitotic kinesin CENP-E is a processive transport motor

    by Hasan Yardimci, Marilyn van Duffelen, Yinghui Mao, Steven S. Rosenfeld, Paul R. Selvin

    In vivo studies suggest that centromeric protein E (CENP-E), a kinesin-7 family member, plays a key role in the movement of chromosomes toward the metaphase plate during mitosis. How CENP-E accomplishes this crucial task, however, is not clear. Here we present single-molecule measurements of CENP-E that demonstrate that this motor moves processively toward the plus end of microtubules, with an average run length of 2.6 ± 0.2 μm, in a hand-over-hand fashion, taking 8-nm steps with a stall force of 6 ± 0.1 pN. The ATP dependence of motor velocity obeys Michaelis–Menten kinetics with K M,ATP = 35 ± 5 μM. All of these features are remarkably similar to those for kinesin-1—a highly processive transport motor. We, therefore, propose that CENP-E transports chromosomes in a manner analogous to how kinesin-1 transports cytoplasmic vesicles.


  • Equipment Setup for Fluorescence Imaging with One-Nanometer Accuracy (FIONA)

    by Paul R. Selvin, Tyler Lougheed, Melinda Tonks Hoffman, Hyokeun Park, Hamza Balci, Benjamin H. Blehm, Erdal Toprak

    INTRODUCTION: FIONA, short for fluorescence imaging with one-nanometer accuracy, is a simple method for achieving localization of single (or single groups of) fluorophores with nanometer accuracy in the xy plane. This article describes procedures for setting up the equipment necessary for FIONA and achieving total internal reflection (TIR).