HHH. David Humes

H. David Humes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


H. David Humes has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • In vivo Assessment of a Manual Single Lumen Alternating Micro-Batch Hemodiafiltration System

    by Sabrina L. Lanker, Christopher J. Pino, H. David Humes, Lakhmir Chawla, Kimberly A. Johnston

    Introduction: The manual single lumen alternating micro-batch hemodiafiltration (mSLAMB) system is a closed-loop dialysis system designed to provide kidney support in emergency situations (e.g., fluid overload, hyperkalemia, acidemia). If done repeatedly in small batches and at high flow rates, this system was found to achieve clearance levels comparable to traditional renal replacement therapy. Methods: Using a porcine model, uremic toxins and exogenous fluorescent tracer concentrations were successfully lowered within just 1 h of treatment. Results: With a maximal dialysate flow, mSLAMB can achieve decreases in serum potassium concentration of >0.5 mmol/L/h. With the mSLAMB hemodiafiltration system, micro-batch processing was also successful in removing up to 250 mL of ultrafiltrate in 8 cycles. Conclusion: This process could create a better fluid balance allowing for administering therapeutic fluids such as sodium bicarbonate in the clinic. Electrolyte imbalance and volume overload remain severe life-threatening emergencies in low resource settings; therefore, mSLAMB should be explored further due to its modest vascular access requirements, low cost, and ability to be performed without electricity or batteries.


  • Open Access

    Regenerative Medicine and Immunomodulatory Therapy: Insights From the Kidney, Heart, Brain, and Lung

    by Christopher J. Pino, Angela J. Westover, Kimberly A. Johnston, Deborah A. Buffington, H. David Humes


  • Bioengineered Renal Cell Therapy Device for Clinical Translation

    by Christopher J. Pino, Angela J. Westover, Deborah A. Buffington, H. David Humes

    The bioartificial renal epithelial cell system (BRECS) is a cell-based device to treat acute kidney injury through renal cell therapy from an extracorporeal circuit. To enable widespread implementation of cell therapy, the BRECS was designed to be cryopreserved as a complete device, cryostored, cryoshipped to an end-use site, thawed as a complete device, and employed in a therapeutic extracorporeal hemofiltration circuit. This strategy overcomes storage and distribution issues that have been previous barriers to cell therapy. Previous BRECS housings produced by computer numerical control (CNC) machining, a slow process taking hours to produce one bioreactor, was also prohibitively expensive (>$600/CNC-BRECS); major obstacles to mass production. The goal of this study was to produce a BRECS to be mass produced by injection-molded BRECS (IM-BRECS), decreasing cost (<$20/unit), and improving manufacturing speed (hundreds of units/h), while maintaining the same cell therapy function as the previous CNC-BRECS, first evaluated through prototypes produced by stereolithography BRECS (SLA-BRECS). The finalized IM-BRECS design had a significantly lower fill volume (10 ml), mass (49 g), and footprint (8.5 cm × 8.5 cm × 1.5 cm), and was demonstrated to outperform the previous BRECS designs with respect to heat transfer, significantly improving control of cooling during cryopreservation and reducing thaw times during warming. During in vitro culture, IM-BRECS performed similarly to previous CNC-BRECS with respect to cell metabolic activity (lactate production, oxygen consumption, and glutathione metabolism) and amount of cells supported.


  • Development of a wearable bioartificial kidney using the Bioartificial Renal Epithelial Cell System (BRECS)

    by Kimberly A. Johnston, Angela J. Westover, Alvaro Rojas-Pena, Deborah A. Buffington, Christopher J. Pino, Peter L. Smith, H. David Humes

    Cell therapy for the treatment of renal failure in the acute setting has proved successful, with therapeutic impact, yet development of a sustainable, portable bioartificial kidney for treatment of chronic renal failure has yet to be realized. Challenges in maintaining an anticoagulated blood circuit, the typical platform for solute clearance and support of the biological components, have posed a major hurdle in advancement of this technology. This group has developed a Bioartificial Renal Epithelial Cell System (BRECS) capable of differentiated renal cell function while sustained by body fluids other than blood. To evaluate this device for potential use in end‐stage renal disease, a large animal model was established that exploits peritoneal dialysis fluid for support of the biological device and delivery of cell therapy while providing uraemic control. Anephric sheep received a continuous flow peritoneal dialysis (CFPD) circuit that included a BRECS. Sheep were treated with BRECS containing 1 × 108 renal epithelial cells or acellular sham devices for up to 7 days. The BRECS cell viability and activity were maintained with extracorporeal peritoneal fluid circulation. A systemic immunological effect of BRECS therapy was observed as cell‐treated sheep retained neutrophil oxidative activity better than sham‐treated animals. This model demonstrates that use of the BRECS within a CFPD circuit embodies a feasible approach to a sustainable and effective wearable bioartificial kidney. Copyright © 2016 John Wiley & Sons, Ltd.


  • Immunomodulatory Device Promotes a Shift of Circulating Monocytes to a Less Inflammatory Phenotype in Chronic Hemodialysis Patients

    by Balazs Szamosfalvi, Angela Westover, Deborah Buffington, Alexander Yevzlin, H. David Humes

    Patients with end-stage renal disease (ESRD) on chronic hemodialysis (HD) suffer accelerated morbidity and mortality rates caused by cardiovascular disease and infections. Chronic inflammation plays a critical role in these poor outcomes. The activated monocyte (MO) has become a prime therapeutic target to modulate this inflammatory process. A selective cytopheretic device (SCD) was evaluated to assess its effects on the circulating MO pool. A pilot trial was undertaken in 15 ESRD patients on HD with C-reactive protein (CRP) levels greater than 5 mg/dl. An excellent safety profile was observed with no decline in leukocyte (LE) or platelet counts. The effect of SCD therapy on MO phenotypes in these patients was determined on peripheral blood MO utilizing flow cytometry. SCD therapy promoted a shift in MO phenotype from predominantly CD14hi expressing MO at baseline/pre-SCD therapy to CD14low expressing MO post-SCD therapy. A significant shift in MO population phenotype afforded by a single SCD therapy session was observed (p < 0.013). In a subset of patients (n = 7) presenting with type 2 diabetes mellitus (T2D), this persistent decline in MO CD14 expression was sustained as long as 2 weeks posttherapy. These results demonstrate that the SCD therapy has the potential to modulate the chronic proinflammatory state in ESRD patients.


  • A bio‐artificial renal epithelial cell system conveys survival advantage in a porcine model of septic shock

    by Angela J. Westover, Deborah A. Buffington, Kimberly A. Johnston, Peter L. Smith, Christopher J. Pino, H. David Humes

    Renal cell therapy using the hollow fiber based renal assist device (RAD) improved survival time in an animal model of septic shock (SS) through the amelioration of cardiac and vascular dysfunction. Safety and ability of the RAD to improve clinical outcomes was demonstrated in a Phase II clinical trial, in which patients had high prevalence of sepsis. Even with these promising results, clinical delivery of cell therapy is hampered by manufacturing hurdles, including cell sourcing, large‐scale device manufacture, storage and delivery. To address these limitations, the bioartificial renal epithelial cell system (BRECS) was developed. The BRECS contains human renal tubule epithelial cells derived from adult progenitor cells using enhanced propagation techniques. Cells were seeded onto trabeculated disks of niobium‐coated carbon, held within cryopreservable, perfusable, injection‐moulded polycarbonate housing. The study objective was to evaluate the BRECS in a porcine model of SS to establish conservation of efficacy after necessary cell sourcing and design modifications; a pre‐clinical requirement to move back into clinical trials. SS was incited by peritoneal injection of E. coli simultaneous to insertion of BRECS (n=10) or control (n=15), into the ultrafiltrate biofeedback component of an extracorporeal circuit. Comparable to RAD, prolonged survival of the BRECS cohort was conveyed through stabilization of cardiac output and vascular leak. In conclusion, the demonstration of conserved efficacy with BRECS therapy in a porcine SS model represents a crucial step toward returning renal cell therapy to the clinical setting, initially targeting ICU patients with acute kidney injury requiring continuous renal replacement therapy. Copyright © 2014 John Wiley & Sons, Ltd.


  • Open Access

    Cell-based approaches for the treatment of systemic inflammation

    by Christopher J. Pino, Alexander S. Yevzlin, Kyungsoo Lee, Angela J. Westover, Peter L. Smith, Deborah A. Buffington, H. David Humes

    Acute and chronic solid organ failures are costly disease processes with high mortality rates. Inflammation plays a central role in both acute and chronic organ failure, including heart, lung and kidney. In this regard, new therapies for these disorders have focused on inhibiting the mediators of inflammation, including cytokines and free radicals, with little or no success in clinical studies. Recent novel treatment strategies have been directed to cell-based rather than mediator-based approaches, designed to immunomodulate the deleterious effects of inflammation on organ function. One approach, cell therapy, replaces cells that were damaged in the acute or chronic disease process with stem/progenitor technology, to rebalance excessive inflammatory states. As an example of this approach, the use of an immunomodulatory role of renal epithelial progenitor cells to treat acute renal failure (ARF) and multiorgan failure arising from acute kidney injury is reviewed. A second therapeutic pathway, cell processing, does not incorporate stem/progenitor cells in the device, but rather biomimetic materials that remove and modulate the primary cellular components, which promote the worsening organ tissue injury associated with inflammation. The use of an immunomodulating leukocyte selective cytopheretic inhibitory device is also reviewed as an example of this cell processing approach. Both of these unconventional strategies have shown early clinical efficacy in pilot clinical trials and may transform the therapeutic approach to organ failure disorders.


  • Selective Cytopheretic Inhibitory Device With Regional Citrate Anticoagulation and Portable Sorbent Dialysis

    by Christopher J. Pino, Amin Farokhrani, Liandi Lou, Peter L. Smith, Kimberly Johnston, Deborah A. Buffington, H. David Humes

    Selective cytopheretic inhibitory device (SCD) therapy is an immunomodulatory treatment provided by a synthetic biomimetic membrane in an extracorporeal circuit, which has shown promise in preclinical large animal models of severe sepsis as well as in clinical trials treating patients with acute kidney injury and multiple organ failure. During SCD therapy, citrate is administered to lower ionized calcium levels in blood for anticoagulation and inhibition of leukocyte activation. Historically, citrate has been known to interfere with sorbent dialysis, therefore, posing a potential issue for the use of SCD therapy with a portable dialysis system. This sorbent dialysis SCD (sorbent SCD) would be well suited for battlefield and natural disaster applications where the water supply for standard dialysis is limited, and the types of injuries in those settings would benefit from SCD therapy. In order to explore the compatibility of sorbent and SCD technologies, a uremic porcine model was tested with the Allient sorbent dialysis system (Renal Solutions Incorporated, Fresenius Medical Care, Warrendale, PA, USA) and concurrent SCD therapy with regional citrate anticoagulation. The hypothesis to be assessed was whether the citrate load required by the SCD could be metabolized prior to recirculation from systemic blood back into the therapeutic circuit. Despite the fact that the sorbent SCD maintained urea clearance without any adverse hematologic events, citrate load for SCD therapy caused an interaction with the sorbent column resulting in elevated, potentially toxic aluminum levels in dialysate and in systemic blood. Alternative strategies to implement sorbent‐SCD therapy will be required, including development of alternate urease‐sorbent column binding chemistry or further changes to the sorbent‐SCD therapeutic circuit along with determining the minimum citrate concentration required for efficacious SCD treatment


  • Open Access

    Bioartificial Renal Epithelial Cell System (BRECS): A Compact, Cryopreservable Extracorporeal Renal Replacement Device

    by Deborah A. Buffington, Christopher J. Pino, Lijun Chen, Angela J. Westover, Gretchen Hageman, H. David Humes

    Renal cell therapy has shown clinical efficacy in the treatment of acute renal failure (ARF) and promise for treatment of end-stage renal disease (ESRD) by supplementing conventional small solute clearance (hemodialysis or hemofiltration) with endocrine and metabolic function provided by cells maintained in an extracorporeal circuit. A major obstacle in the widespread adoption of this therapeutic approach is the lack of a cryopreservable system to enable distribution, storage, and therapeutic use at point of care facilities. This report details the design, fabrication, and assessment of a Bioartificial Renal Epithelial Cell System (BRECS), the first all-in-one culture vessel, cryostorage device, and cell therapy delivery system. The BRECS was loaded with up to 20 cell-seeded porous disks, which were maintained by perfusion culture. Once cells reached over 5×106 cells/disk for a total therapeutic dose of approximately 108 cells, the BRECS was cryopreserved for storage at –80°C or –140°C. The BRECS was rapidly thawed, and perfusion culture was resumed. Near precryopreservation values of cell viability, metabolic activity, and differentiated phenotype of functional renal cells were confirmed postreconstitution. This technology could be extended to administer other cell-based therapies where metabolic, regulatory, or secretion functions can be leveraged in an immunoisolated extracorporeal circuit.