Andrew G. Webb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrew G. Webb has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xiaofeng Zhang
Department of Radiology, Duke University Medical Center, DUMC 3808, Durham, NC 27710, USA
2 shared publications Xiaozhong Zhang
Department of Electrical and Computer Engineering, University of Illinois at Urbana‐Champaign, Urbana, Illinois, USA
2 shared publicationsB. Behnia
Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Engineering, University of Illinois at Urbana‐Champaign, Urbana, Illinois 61801
1 shared publication- Bradley P. Sutton
University of Illinois at Urbana-Champaign
1 shared publication - Luisa Ciobanu
NeuroSpin, CEA, Gif-sur-Yvette, Paris-Saclay University, Saclay, France
1 shared publication Vladislav Y. Toronov
1 shared publication
Latest Publications
- 26 October 2005
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 27B (1) , 8-16
Characterization of B1 field focussing effects in magnetic resonance spectroscopy and imaging at 17.6 tesla
- 26 October 2005
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 27B (1) , 8-16
Characterization of B1 field focussing effects in magnetic resonance spectroscopy and imaging at 17.6 tesla
- 1 August 2005
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 38 (5) , 892-903
Microcoil nuclear magnetic resonance spectroscopy
- 1 August 2005
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 38 (5) , 892-903
Microcoil nuclear magnetic resonance spectroscopy
- 27 July 2005
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 43 (9) , 688-696
Nuclear magnetic resonance coupled microseparations
The increased separation efficiency afforded by reducing the size of the separation column has resulted in ‘microseparations’ becoming an important component in many chemical and biochemical applications. The coupling of microseparations with NMR detection is an area of increasing interest owing to the high structural information of NMR. In order to couple efficiently with the separation, the NMR detector must be reduced in size to correspond to that of the separation peak. This paper summarizes some of the approaches used in coupling NMR detection with pressure‐driven and electrophoretic microseparations, the design of small NMR detectors and applications of this technology. Copyright © 2005 John Wiley & Sons, Ltd.
- 27 July 2005
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 43 (9) , 688-696
Nuclear magnetic resonance coupled microseparations
The increased separation efficiency afforded by reducing the size of the separation column has resulted in ‘microseparations’ becoming an important component in many chemical and biochemical applications. The coupling of microseparations with NMR detection is an area of increasing interest owing to the high structural information of NMR. In order to couple efficiently with the separation, the NMR detector must be reduced in size to correspond to that of the separation peak. This paper summarizes some of the approaches used in coupling NMR detection with pressure‐driven and electrophoretic microseparations, the design of small NMR detectors and applications of this technology. Copyright © 2005 John Wiley & Sons, Ltd.
- 20 June 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (1) , 9-13
Parallel imaging for NMR microscopy at 14.1 Tesla
Parallel imaging techniques using arrays of mutually decoupled coils have become standard on almost all clinical imaging systems. Such techniques also have great potential for high‐field magnetic resonance (MR) microscopy, where measurement times are usually long and susceptibility artifacts can be severe. However, it is technically very challenging to design efficient high‐frequency phased arrays for small‐diameter, vertical‐bore magnets, especially since standard decoupling methods, such as impedance mismatched preamplifiers, cannot be easily integrated. A four‐coil phased array was constructed for microimaging at 600 MHz, and sensitivity encoding (SENSE) and generalized autocalibrating partially parallel acquisitions (GRAPPA) reconstructions of spin‐echo and echo‐planar images of the mouse brain were performed to reduce imaging time and susceptibility artifacts, respectively. Magn Reson Med 54:9–13, 2005.
- 20 June 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (1) , 9-13
Parallel imaging for NMR microscopy at 14.1 Tesla
Parallel imaging techniques using arrays of mutually decoupled coils have become standard on almost all clinical imaging systems. Such techniques also have great potential for high‐field magnetic resonance (MR) microscopy, where measurement times are usually long and susceptibility artifacts can be severe. However, it is technically very challenging to design efficient high‐frequency phased arrays for small‐diameter, vertical‐bore magnets, especially since standard decoupling methods, such as impedance mismatched preamplifiers, cannot be easily integrated. A four‐coil phased array was constructed for microimaging at 600 MHz, and sensitivity encoding (SENSE) and generalized autocalibrating partially parallel acquisitions (GRAPPA) reconstructions of spin‐echo and echo‐planar images of the mouse brain were performed to reduce imaging time and susceptibility artifacts, respectively. Magn Reson Med 54:9–13, 2005.
- 14 February 2005
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 24B (1) , 6-14
Design of a four-coil surface array for in vivo magnetic resonance microscopy at 600 MHz
- 14 February 2005
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 24B (1) , 6-14
Design of a four-coil surface array for in vivo magnetic resonance microscopy at 600 MHz
- 2 February 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (5) , 1338-1344
Magnetic Resonance Microimaging and Numerical Simulations of Velocity Fields Inside Enlarged Flow Cells Used for Coupled NMR Microseparations
The coupling of various chemical microseparation methods with small-scale NMR detection is a growing area in analytical chemistry. The formation of enlarged flow cells within the active volume of the NMR detector can significantly increase the coil filling factor and hence the signal-to-noise ratio of the NMR spectra. However, flow cells can also lead to deterioration of the separation efficiency due to the development of complex flow patterns, the form of which depend on the particular geometry of the flow cell and the flow rate used. In this study, we investigated the flow characteristics in different flow cell geometries relevant to the coupling of capillary liquid chromatography and NMR. Computational fluid dynamics was used to simulate fluid flow inside flow cells with a volume of ∼1 μL. Magnetic resonance microimaging was used to measure experimentally the velocity fields inside these flow cells. The results showed good agreement between experiment and simulation and demonstrated that a relatively gradual expansion and contraction is necessary to avoid areas of weak recirculation and strong radial velocities, both of which can potentially compromise separation efficiency.
- 2 February 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (5) , 1338-1344
Magnetic Resonance Microimaging and Numerical Simulations of Velocity Fields Inside Enlarged Flow Cells Used for Coupled NMR Microseparations
The coupling of various chemical microseparation methods with small-scale NMR detection is a growing area in analytical chemistry. The formation of enlarged flow cells within the active volume of the NMR detector can significantly increase the coil filling factor and hence the signal-to-noise ratio of the NMR spectra. However, flow cells can also lead to deterioration of the separation efficiency due to the development of complex flow patterns, the form of which depend on the particular geometry of the flow cell and the flow rate used. In this study, we investigated the flow characteristics in different flow cell geometries relevant to the coupling of capillary liquid chromatography and NMR. Computational fluid dynamics was used to simulate fluid flow inside flow cells with a volume of ∼1 μL. Magnetic resonance microimaging was used to measure experimentally the velocity fields inside these flow cells. The results showed good agreement between experiment and simulation and demonstrated that a relatively gradual expansion and contraction is necessary to avoid areas of weak recirculation and strong radial velocities, both of which can potentially compromise separation efficiency.
- 1 January 2005
- Published by Optica Publishing Group in Optics Express
- Vol. 13 (14) , 5513-21
Simultaneous integrated diffuse optical tomography and functional magnetic resonance imaging of the human brain
A complete methodology has been developed to integrate simultaneous diffuse optical tomography (DOT) and functional magnetic resonance imaging (MRI) measurements. This includes development of an MRI-compatible optical probe and a method for accurate estimation of the positions of the source and detector optodes in the presence of subject-specific geometric deformations of the optical probe. Subject-specific head models are generated by segmentation of structural MR images. DOT image reconstruction involves solution of the forward problem of light transport in the head using Monte Carlo simulations, and inversion of the linearized problem for small perturbations of the absorption coefficient. Initial results show good co-localization between the DOT images of changes in oxy- and deoxyhemoglobin concentration and functional MRI data.
- 1 January 2005
- Published by Optica Publishing Group in Optics Express
- Vol. 13 (14) , 5513-21
Simultaneous integrated diffuse optical tomography and functional magnetic resonance imaging of the human brain
A complete methodology has been developed to integrate simultaneous diffuse optical tomography (DOT) and functional magnetic resonance imaging (MRI) measurements. This includes development of an MRI-compatible optical probe and a method for accurate estimation of the positions of the source and detector optodes in the presence of subject-specific geometric deformations of the optical probe. Subject-specific head models are generated by segmentation of structural MR images. DOT image reconstruction involves solution of the forward problem of light transport in the head using Monte Carlo simulations, and inversion of the linearized problem for small perturbations of the absorption coefficient. Initial results show good co-localization between the DOT images of changes in oxy- and deoxyhemoglobin concentration and functional MRI data.
- 21 October 2004
- Published by Wiley in Concepts in Magnetic Resonance
- Vol. 23B (1) , 1-15
MRI-monitored electromagnetic heating using iterative feedback control and phase interference mapping
- 21 October 2004
- Published by Wiley in Concepts in Magnetic Resonance
- Vol. 23B (1) , 1-15
MRI-monitored electromagnetic heating using iterative feedback control and phase interference mapping
- 28 April 2004
- Published by Wiley in Concepts in Magnetic Resonance Part A
- Vol. 22A (1) , 25-36
Optimizing the point spread function in phase‐encoded magnetic resonance microscopy
- 28 April 2004
- Published by Wiley in Concepts in Magnetic Resonance Part A
- Vol. 22A (1) , 25-36
Optimizing the point spread function in phase‐encoded magnetic resonance microscopy