VBVanderlei Salvador Bagnato

Vanderlei Salvador Bagnato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vanderlei Salvador Bagnato has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a protocol for whole-lung in vivo lung perfusion-assisted photodynamic therapy using a porcine model

    by Khaled Ramadan, Tina Saeidi, Edson Brambate, Vanderlei Bagnato, Marcelo Cypel, Lothar Lilge

    SignificanceStandard treatments for isolated lung metastases remain a clinical challenge. In vivo lung perfusion technique provides flexibility to overcome the limitations of photodynamic therapy (PDT) by replacing the blood with acellular perfusate, allowing greater light penetration.AimUsing Monte Carlo-based simulations, we will evaluate the abilities of a light delivery system to irradiate the lung homogenously. Afterward, we aim to demonstrate the feasibility and safety profile of a whole-lung perfusion-assisted PDT protocol using 5-ALA and Chlorin e6.ApproachA porcine model of a simplified lung perfusion procedure was used. PDT was performed at 630 or 660 nm with 5-ALA or Chlorin e6, respectively. Light fluence rate measurements and computed tomography (CT) scan segmentations were used to create in silico models of light propagation. Physiologic, gross, CT, and histological assessment of lung toxicity was performed 72 h post-PDT.ResultsDose-volume histograms showed homogeneity of light intensity throughout the lung. Predicted and measured fluence rates showed strong reliability. The photodynamic threshold of 5-ALA was 2.10×1017±8.24×1016 hν/cm3, whereas Chlorin e6 showed negligible uptake in lung tissue.ConclusionsWe lay the groundwork for personalized preoperative in silico dosimetry planning to achieve desired treatment volumes within the therapeutic range. Chlorin e6 demonstrated the greatest therapeutic potential, with a minimal uptake in healthy lung tissues.


  • Violet LED for non-vital tooth bleaching as a new approach

    by Eran Nair Mesquita de Almeida, João Felipe Bessegato, Diego Dantas Lopes dos Santos, Alessandra Nara de Souza Rastelli, Vanderlei Salvador Bagnato


  • Violet LED with low concentration carbamide peroxide for dental bleaching: A case report

    by Alessandra Nara de Souza Rastelli, Hércules Bezerra Dias, Emanuelle Teixeira Carrera, Ana Cláudia Pedroso de Barros, Diego Dantas Lopes dos Santos, Vitor Hugo Panhóca, Vanderlei Salvador Bagnato


  • Comparative clinical study of light analgesic effect on temporomandibular disorder (TMD) using red and infrared led therapy

    by Vitor Hugo Panhoca, Rosane de Fatima Zanirato Lizarelli, Silvia Cristina Nunez, Renata Campi de Andrade Pizzo, Clovis Grecco, Fernanda Rossi Paolillo, Vanderlei Salvador Bagnato

    Low-level laser therapy (LLLT) has been widely applied in pain relief in several clinical situations, including temporomandibular disorders (TMD). However, the effects of LED therapy on TMD has not been investigated. This study aims to evaluate the effects of red and infrared LEDs on: (1) tissue temperature in ex vivo and (2) pain relief and mandibular range of motion in patients with TMD. Thirty patients between 18 and 40 years old were included and randomly assigned to three groups. The two experimental groups were: the red LED (630 ± 10 nm) group and the infrared LED (850 ± 10 nm) group. The irradiation parameters were 150 mW, 300 mW/cm2, 18 J/cm2, and 9 J/point. The positive control group received an infrared laser (780 nm) with 70 mW, 1.7 W/cm2, 105 J/cm2, and 4.2 J/point. LED and laser therapies were applied bilaterally to the face for 60 s/point. Five points were irradiated: three points around the temporomandibular joint (TMJ), one point for the temporalis, and one near the masseter. Eight sessions of phototherapy were performed, twice a week for 4 weeks. Pain induced by palpating the masseter muscle and mandibular range of motion (maximum oral aperture) were measured at baseline, immediately after treatment, 7 days after treatment, and 30 days after treatment. There was an increase in tissue temperature during both the red and the infrared LED irradiation in ex vivo. There was a significant reduction of pain and increase of the maximum oral aperture for all groups (p ≥ 0.05). There was no significant difference in pain scores and maximum oral aperture between groups at baseline or any periods after treatment (p ≥ 0.05). The current study showed that red and infrared LED therapy can be useful in improving outcomes related to pain relief and orofacial function for TMD patients. We conclude that LED devices constitute an attractive alternative for LLLT.


  • Time progression of ultrashort laser ablation in a transparent material

    by G. Nicolodelli, R. F. Z. Lizarelli, M. M. Costa, V. S. Bagnato

    Laser ablation on the ultra-short-pulses regime (femtosecond), has an impact on materials processing and micromachining in a quite profound ways. The investigation of the time progression of the laser ablation process within the material can produce much information and it is not conventionally used. The implementation of such study is the main aim of this paper. The temporal dependence of the diameter and depth of micro-drilling in the sample was verified, beyond the simple understanding of the mechanism for plasma generated during the ablation. From the monitoring of the time progression of the ablation, the time dependence for the velocity of ablation had been determined. In most cases, fume attenuation of the incoming laser beam and fume escape paths, produce dominant influence the characteristics of the region ablated. The method here employed is simple and can be carried out in real time without interruption of the process. In the implemented method light scattered from an auxiliary source allow visualization and record of the ablated geometry as it progress.


  • Open Access

    The Brazilian time and frequency atomic standards program.

    by Mushtaq Ahmed, Daniel V. Magalhães, Aida Bebeachibuli, Stella T. Müller, Renato F. Alves, Tiago A. Ortega, John Weiner, Vanderlei S. Bagnato

    Cesium atomic beam clocks have been the workhorse for many demanding applications in science and technology for the past four decades. Tests of the fundamental laws of physics and the search for minute changes in fundamental constants, the synchronization of telecommunication networks, and realization of the satellite-based global positioning system would not be possible without atomic clocks. The adoption of optical cooling and trapping techniques, has produced a major advance in atomic clock precision. Cold-atom fountain and compact cold-atom clocks have also been developed. Measurement precision of a few parts in 10(15) has been demonstrated for a cold-atom fountain clock. We present here an overview of the time and frequency metrology program based on cesium atoms under development at USP São Carlos. This activity consists of construction and characterization of atomic-beam, and several variations of cold-atom clocks. We discuss the basic working principles, construction, evaluation, and important applications of atomic clocks in the Brazilian program.


  • Temperature determination for magneto optical trapped atoms using a single parameter transient absorption

    by R.R. Silva, K.M.F. Magalhães, E.A.L. Henn, L.G. Marcassa, V.S. Bagnato


  • Comparative short-term stability for a Cs beam and an expanding cold atomic cloud of Cs used as atomic frequency standards

    by D. V. Magalhães, S. T. Müller, A. Bebeachibuli, R. F. Alves, V. S. Bagnato

    We have compared the stability of two distinct atomic frequency standards. One is based on an atomic cold cloud of 133Cs atoms in free expansion, interrogated by a Rabi resonance. The other standard is based on a thermal Cs beam interrogated by the separated oscillatory field method (Ramsey’s method). The atomic expanding cloud standard shows better stability and technical advances based on its simplicity.


  • Correlation between the photostability and photodynamic efficacy for different photosensitizers

    by J Ferreira, C Kurachi, L T Moriyama, P F C Menezes, J R Perussi, C Sibata, S Zucoloto, O Castro e Silva Jr, V S Bagnato

    Using three haematoporphyrin based photosensitizers we investigated their properties related to the phototransformation in solution, the inhibitory concentration (IC50) in cell culture and the threshold dose (Dth) in rat livers. The observation of such properties shows the existence of a strong correlation among them. The photosensitizer with the highest phototransformation rate is also the one with the lowest Dth and IC50, showing more efficacy in cell killing and tissue necrosis during photodynamic therapy applications. We discuss this explanation for such correlation and the possible practical applications for this property.


  • Variation of the mean kinetic temperature of magnetically trapped atoms by external shaking perturbation

    by E A L Henn, K M F Magalhães, S R Muniz, R R Silva, L G Marcassa, V S Bagnato

    Using a shaking field overlaped to the static field of a quadrupole trap we have performed experiments with cold Na atoms held in a magnetic trap. As a function of the shaking frequency the temperature of the atomic cloud is measured by time-of-flight. We observe results similar to Kumakura et al. [Phys. Rev. A 68, 021401(R)] and the variations of the kinetic temperature in our results are explained based on a model where we selectively affect different velocity classes.