Siao-Ying Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Siao-Ying Chen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chao-Sung Lin
Department of Materials Science and Engineering, National Taiwan University, Taipei 106, Taiwan
5 shared publications - Zong-Syun Yang2 shared publications
Chao-Sung Lin
National Taiwan University
1 shared publicationChao-Yu Huang
1 shared publicationGuan-Ting Shen
1 shared publicationHan-Sheng Huang
1 shared publication
Latest Publications
- 15 July 2025
- Published by Elsevier in Corrosion Science
- Vol. 256
Formation mechanism of Zr-based conversion coating on 6061-T6 Al and C1100 Cu galvanic couple
- 15 July 2025
- Published by Elsevier in Corrosion Science
- Vol. 256
Formation mechanism of Zr-based conversion coating on 6061-T6 Al and C1100 Cu galvanic couple
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (20) , 1352
Characterization of the Conversion Coating on 7075-T6 Al Alloy in Trivalent Chromium-Based Solutions: The Effect of Free Fluoride Ions
Trivalent chromium process (TCP) is one of the promising alternatives to chromate conversion coating (CCC). For the CCC process, the main electroactive component of the solution is Cr6+ [1]. In the TCP solution, the main components are Cr3+ and ZrF6 2- [2]. Due to environmental and health concerns, non-chromate coating systems are developed. For example, fluorozirconate coating systems contain Zr4+ (ZrF6 2-) and small amounts of non-chromium metal ions, such as TiF6 2- and Zn2+ [3]. In response to international regulations, TCP is also expected to be replaced. However, it is interesting why ZrF6 2- is the main component of commercial TCP solutions. In this study, 7075-T6 Al alloys were treated in Cr3+ conversion solutions without and with 0.0005 M F- for 1, 10, and 30 min. SEM characterization revealed that the morphology of 7075-T6 Al after conversion coating in Cr3+ solutions was similar to the counterpart after alkaline degreasing and acidic desmutting. Moreover, the Cr signal was not acquired in EDS spectrums. The polarization curves recorded in 0.5 M Na2SO4 + 0.05 M NaCl showed insignificant inhibition in anodic and cathodic kinetics. A protective conversion coating cannot grow in Cr3+ solutions with 0.0005 M F-. However, a protective conversion coating formed in the Cr3+ solution with a higher F- concentration. The 7075-T6 Al alloy treated in the Cr3+ solution containing 0.072 M F- for 1 min exhibited inhibited anodic and cathodic kinetics. Cross-sectional TEM characterization revealed the formation of a 30-nm-thick, Cr-rich coating. As a result, the continuous, thin Cr-rich coating confers corrosion resistance. However, a local corrosion attack was observed on the sample with extended conversion coating treatments. Grain boundaries of 7075-T6 were etched severely after 10 min of conversion coating treatment. Large corrosion spots appeared after 30 min of conversion coating treatment. Consequently, F- facilitates the conversion coating reaction in Cr3+ solutions via the attack of the substrate. However, F- can have negative effects on the continuity and integrity of the coating, specifically extended treatment in the solution with larger F- concentrations. Reference: Suib, S. L., La Scala, J., Nickerson, W., Fowler, A., & Zaki, N. (2009). Determination of hexavalent chromium in NAVAIR trivalent chromium process (TCP) coatings and process solutions. Metal Finishing, 107(2), 28-34. Munson, C. A., et al. (2018). "Cross comparison of TCP conversion coating performance on aluminum alloys during neutral salt-spray and thin-layer mist accelerated degradation testing." Electrochimica Acta 282: 171-184 Milošev, I., & Frankel, G. S. (2018). Conversion coatings based on zirconium and/or titanium. Journal of The Electrochemical Society, 165(3), C127-C144.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (20) , 1352
Characterization of the Conversion Coating on 7075-T6 Al Alloy in Trivalent Chromium-Based Solutions: The Effect of Free Fluoride Ions
Trivalent chromium process (TCP) is one of the promising alternatives to chromate conversion coating (CCC). For the CCC process, the main electroactive component of the solution is Cr6+ [1]. In the TCP solution, the main components are Cr3+ and ZrF6 2- [2]. Due to environmental and health concerns, non-chromate coating systems are developed. For example, fluorozirconate coating systems contain Zr4+ (ZrF6 2-) and small amounts of non-chromium metal ions, such as TiF6 2- and Zn2+ [3]. In response to international regulations, TCP is also expected to be replaced. However, it is interesting why ZrF6 2- is the main component of commercial TCP solutions. In this study, 7075-T6 Al alloys were treated in Cr3+ conversion solutions without and with 0.0005 M F- for 1, 10, and 30 min. SEM characterization revealed that the morphology of 7075-T6 Al after conversion coating in Cr3+ solutions was similar to the counterpart after alkaline degreasing and acidic desmutting. Moreover, the Cr signal was not acquired in EDS spectrums. The polarization curves recorded in 0.5 M Na2SO4 + 0.05 M NaCl showed insignificant inhibition in anodic and cathodic kinetics. A protective conversion coating cannot grow in Cr3+ solutions with 0.0005 M F-. However, a protective conversion coating formed in the Cr3+ solution with a higher F- concentration. The 7075-T6 Al alloy treated in the Cr3+ solution containing 0.072 M F- for 1 min exhibited inhibited anodic and cathodic kinetics. Cross-sectional TEM characterization revealed the formation of a 30-nm-thick, Cr-rich coating. As a result, the continuous, thin Cr-rich coating confers corrosion resistance. However, a local corrosion attack was observed on the sample with extended conversion coating treatments. Grain boundaries of 7075-T6 were etched severely after 10 min of conversion coating treatment. Large corrosion spots appeared after 30 min of conversion coating treatment. Consequently, F- facilitates the conversion coating reaction in Cr3+ solutions via the attack of the substrate. However, F- can have negative effects on the continuity and integrity of the coating, specifically extended treatment in the solution with larger F- concentrations. Reference: Suib, S. L., La Scala, J., Nickerson, W., Fowler, A., & Zaki, N. (2009). Determination of hexavalent chromium in NAVAIR trivalent chromium process (TCP) coatings and process solutions. Metal Finishing, 107(2), 28-34. Munson, C. A., et al. (2018). "Cross comparison of TCP conversion coating performance on aluminum alloys during neutral salt-spray and thin-layer mist accelerated degradation testing." Electrochimica Acta 282: 171-184 Milošev, I., & Frankel, G. S. (2018). Conversion coatings based on zirconium and/or titanium. Journal of The Electrochemical Society, 165(3), C127-C144.
- 20 February 2025
- Published by Elsevier in Corrosion Science
- Vol. 248
A MnO2-ZrO2 composite conversion coating to enhance. the corrosion resistance of WE43-T5 Mg alloys
- 20 February 2025
- Published by Elsevier in Corrosion Science
- Vol. 248
A MnO2-ZrO2 composite conversion coating to enhance. the corrosion resistance of WE43-T5 Mg alloys
- Open Access
- 9 January 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 28, 4567-4576
Effect of bath temperature on the growth kinetics and characteristics of permanganate conversion coating on LZ91 magnesium alloy
- 9 January 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 28, 4567-4576
Open AccessEffect of bath temperature on the growth kinetics and characteristics of permanganate conversion coating on LZ91 magnesium alloy