Yoshiaki Honjo
Yoshiaki Honjo has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Haruki Nishino
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
5 shared publications - Takaki Hatsui
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
5 shared publications - Kyosuke Ozaki
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
4 shared publications - Toshiyuki Nishiyama Hiraki
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
4 shared publications - Yasumasa Joti
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
4 shared publications - Makina Saito
Department of Physics, Tohoku University, Sendai, Japan
2 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (6) , 1769-1778
Time-resolved coherent X-ray scattering analysis of nanorod colloids: dynamics and photon-statistical effects in angular X-ray cross-correlation analysis
Understanding the dynamic fluctuations of anisotropic particles is essential for elucidating the mechanisms of order formation through self-organization. Because anisotropic particles possess both translational and rotational degrees of freedom, their dynamics are intrinsically more complex than those of spherical particles. Time-resolved coherent X-ray scattering has the potential to probe such complex dynamics. Translational motion can be evaluated by X-ray photon correlation spectroscopy (XPCS), whereas orientational information can be extracted using the angular X-ray cross-correlation function (AXCCF). In this study, we investigated dynamic fluctuations in a colloidal nanorod system at concentrations near the coexistence region of isotropic and liquid-crystalline phases using time-resolved coherent X-ray scattering at 17.4 kHz. XPCS analysis revealed a pronounced slowing down of translational motion as the isotropic phase approached the liquid-crystalline phase. To examine possible temporal fluctuations in orientational order near the coexistence region, we applied a statistical approach based on AXCCF and principal component analysis. Temporal variations were indeed observed in the AXCCF. However, quantitative analysis showed that the magnitude and distribution of these variations are largely explained by photon-counting statistics expected for coherent scattering under low-count conditions. Although the present experiment did not provide definitive evidence for intrinsic orientational fluctuations beyond statistical noise, the analysis establishes an important framework for evaluating the detectability of orientational dynamics in time-resolved coherent X-ray scattering experiments and provides practical guidance for future measurements and validation.
- 27 October 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (6) , 1769-1778
Open AccessTime-resolved coherent X-ray scattering analysis of nanorod colloids: dynamics and photon-statistical effects in angular X-ray cross-correlation analysis
Understanding the dynamic fluctuations of anisotropic particles is essential for elucidating the mechanisms of order formation through self-organization. Because anisotropic particles possess both translational and rotational degrees of freedom, their dynamics are intrinsically more complex than those of spherical particles. Time-resolved coherent X-ray scattering has the potential to probe such complex dynamics. Translational motion can be evaluated by X-ray photon correlation spectroscopy (XPCS), whereas orientational information can be extracted using the angular X-ray cross-correlation function (AXCCF). In this study, we investigated dynamic fluctuations in a colloidal nanorod system at concentrations near the coexistence region of isotropic and liquid-crystalline phases using time-resolved coherent X-ray scattering at 17.4 kHz. XPCS analysis revealed a pronounced slowing down of translational motion as the isotropic phase approached the liquid-crystalline phase. To examine possible temporal fluctuations in orientational order near the coexistence region, we applied a statistical approach based on AXCCF and principal component analysis. Temporal variations were indeed observed in the AXCCF. However, quantitative analysis showed that the magnitude and distribution of these variations are largely explained by photon-counting statistics expected for coherent scattering under low-count conditions. Although the present experiment did not provide definitive evidence for intrinsic orientational fluctuations beyond statistical noise, the analysis establishes an important framework for evaluating the detectability of orientational dynamics in time-resolved coherent X-ray scattering experiments and provides practical guidance for future measurements and validation.
- Open Access
- 25 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 609-616
FPGA-accelerated streaming data reduction achieving an average compression ratio over 8000 in a 17.4 kHz, 840 kpixel CITIUS detector for quasi-elastic gamma-ray scattering
We present a data-acquisition and -analysis framework for quasi-elastic gamma-ray scattering (QEGS) experiments at BL35XU of SPring-8, equipped with an 840 kpixel CITIUS X-ray detector operating at 17.4 kHz. The detector produces data at 27 GB s −1 (216 Gbps), and typical experiments involve acquisition over beam-time periods longer than 24 h, generating datasets of 2.3 PB per day. To handle this volume, we constructed a data-handling pipeline consisting of the detector, data reduction at the beamline and analysis tools at the data center. The data reduction employs field-programmable gate array (FPGA)-accelerated per-pixel processing to reduce data entropy, followed by Zstandard compression on CPUs, achieving an average compression ratio of over 8000. The compressed data are transferred to the SPring-8 data center within two to three minutes of data acquisition. At the data center, analysis tools are provided via the Open OnDemand platform, enabling incremental integration and spectral analysis through a web-based interface without the need for high-performance-computing command-line interaction. This data-handling pipeline has been applied in QEGS user experiments, where it enabled timely feedback on experimental data, with integrated results available within six minutes and spectral analysis within seven minutes of integration.
- 25 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 609-616
Open AccessFPGA-accelerated streaming data reduction achieving an average compression ratio over 8000 in a 17.4 kHz, 840 kpixel CITIUS detector for quasi-elastic gamma-ray scattering
We present a data-acquisition and -analysis framework for quasi-elastic gamma-ray scattering (QEGS) experiments at BL35XU of SPring-8, equipped with an 840 kpixel CITIUS X-ray detector operating at 17.4 kHz. The detector produces data at 27 GB s −1 (216 Gbps), and typical experiments involve acquisition over beam-time periods longer than 24 h, generating datasets of 2.3 PB per day. To handle this volume, we constructed a data-handling pipeline consisting of the detector, data reduction at the beamline and analysis tools at the data center. The data reduction employs field-programmable gate array (FPGA)-accelerated per-pixel processing to reduce data entropy, followed by Zstandard compression on CPUs, achieving an average compression ratio of over 8000. The compressed data are transferred to the SPring-8 data center within two to three minutes of data acquisition. At the data center, analysis tools are provided via the Open OnDemand platform, enabling incremental integration and spectral analysis through a web-based interface without the need for high-performance-computing command-line interaction. This data-handling pipeline has been applied in QEGS user experiments, where it enabled timely feedback on experimental data, with integrated results available within six minutes and spectral analysis within seven minutes of integration.
- 17 June 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (25) , 256901
Broadband Quasielastic Scattering Spectroscopy Using a Multiline Frequency Comblike Spectrum in the Hard X-Ray Region
We developed a novel quasielastic scattering spectroscopy system that uses a multiline frequency comblike resolution function to overcome the limit on the accessible timescale imposed by the inherent single-energy resolution of conventional spectroscopy systems. The new multiline system possesses multiple resolutions and can efficiently cover a wide time range, from 100 ps to 100 ns, where x-ray-based dynamic measurement techniques are being actively developed. It enables visualization of the relaxation shape and wave-number-dependent dynamic behavior using a two-dimensional detector, as demonstrated for the natural polymer polybutadine without deuteration.
- 17 June 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (25) , 256901
Broadband Quasielastic Scattering Spectroscopy Using a Multiline Frequency Comblike Spectrum in the Hard X-Ray Region
We developed a novel quasielastic scattering spectroscopy system that uses a multiline frequency comblike resolution function to overcome the limit on the accessible timescale imposed by the inherent single-energy resolution of conventional spectroscopy systems. The new multiline system possesses multiple resolutions and can efficiently cover a wide time range, from 100 ps to 100 ns, where x-ray-based dynamic measurement techniques are being actively developed. It enables visualization of the relaxation shape and wave-number-dependent dynamic behavior using a two-dimensional detector, as demonstrated for the natural polymer polybutadine without deuteration.
- Open Access
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 989-994
High-resolution and high-sensitivity X-ray ptychographic coherent diffraction imaging using the CITIUS detector
Ptychographic coherent diffraction imaging (PCDI) is a synchrotron X-ray microscopy technique that provides high spatial resolution and a wide field of view. To improve the performance of PCDI, the performance of the synchrotron radiation source and imaging detector should be improved. In this study, ptychographic diffraction pattern measurements using the CITIUS high-speed X-ray image detector and the corresponding image reconstruction are reported. X-rays with an energy of 6.5 keV were focused by total reflection focusing mirrors, and a flux of ∼2.6 × 1010 photons s−1 was obtained at the sample plane. Diffraction intensity data were collected at up to ∼250 Mcounts s−1 pixel−1 without saturation of the detector. Measurements of tantalum test charts and silica particles and the reconstruction of phase images were performed. A resolution of ∼10 nm and a phase sensitivity of ∼0.01 rad were obtained. The CITIUS detector can be applied to the PCDI observation of various samples using low-emittance synchrotron radiation sources and to the stability evaluation of light sources.
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 989-994
Open AccessHigh-resolution and high-sensitivity X-ray ptychographic coherent diffraction imaging using the CITIUS detector
Ptychographic coherent diffraction imaging (PCDI) is a synchrotron X-ray microscopy technique that provides high spatial resolution and a wide field of view. To improve the performance of PCDI, the performance of the synchrotron radiation source and imaging detector should be improved. In this study, ptychographic diffraction pattern measurements using the CITIUS high-speed X-ray image detector and the corresponding image reconstruction are reported. X-rays with an energy of 6.5 keV were focused by total reflection focusing mirrors, and a flux of ∼2.6 × 1010 photons s−1 was obtained at the sample plane. Diffraction intensity data were collected at up to ∼250 Mcounts s−1 pixel−1 without saturation of the detector. Measurements of tantalum test charts and silica particles and the reconstruction of phase images were performed. A resolution of ∼10 nm and a phase sensitivity of ∼0.01 rad were obtained. The CITIUS detector can be applied to the PCDI observation of various samples using low-emittance synchrotron radiation sources and to the stability evaluation of light sources.
- Open Access
- 12 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1032-1037
Bragg coherent diffraction imaging with the CITIUS charge-integrating detector
The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel−1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ± 6 nm versus 22 ± 9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.
- 12 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1032-1037
Open AccessBragg coherent diffraction imaging with the CITIUS charge-integrating detector
The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel−1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ± 6 nm versus 22 ± 9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.