Bragg coherent diffraction imaging with the CITIUS charge-integrating detector
Authors:
- Michael GrimesMGMichael Grimes
- Kristof PauwelsKPKristof Pauwels
- Tobias U. SchülliTSTobias U. Schülli
- Thierry MartinTMThierry Martin
- Pablo FajardoPFPablo Fajardo
- Paul-Antoine DouissardPDPaul-Antoine Douissard
- Menyhert KocsisMKMenyhert Kocsis
- Haruki NishinoHNHaruki Nishino
- Kyosuke OzakiKOKyosuke Ozaki
- Yoshiaki HonjoYHYoshiaki Honjo
- Toshiyuki Nishiyama HirakiTHToshiyuki Nishiyama Hiraki
- Yasumasa JotiYJYasumasa Joti
Open Access
- 12 June 2023
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1032-1037
Abstract
The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel−1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ± 6 nm versus 22 ± 9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.Keywords
Funding Information
- H2020 European Research Council (818823)
This publication has 22 references indexed in Scilit:
- A Medium-Format, Mixed-Mode Pixel Array Detector for Kilohertz X-ray ImagingJournal of Physics: Conference Series, 2013
- High-resolution three-dimensional partially coherent diffraction imagingNature Communications, 2012
- Fast computation of scattering maps of nanostructures using graphical processing unitsJournal of Applied Crystallography, 2011
- MAXIPIX, a fast readout photon-counting X-ray area detector for synchrotron applicationsJournal of Instrumentation, 2011
- Performance of single-photon-counting PILATUS detector modulesJournal of Synchrotron Radiation, 2009
- Relaxed averaged alternating reflections for diffraction imagingInverse Problems, 2004
- X-ray image reconstruction from a diffraction pattern alonePhysical Review B, 2003
- X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92Atomic Data and Nuclear Data Tables, 1993
- Reconstruction of an object from the modulus of its Fourier transformOptics Letters, 1978
- Beugung im inhomogenen Primärstrahlwellenfeld. I. Prinzip einer Phasenmessung von ElektronenbeungungsinterferenzenActa Crystallographica Section A, 1969