Nafiseh Fahimi-Kashani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nafiseh Fahimi-Kashani has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Reza Hormozi-Nezhad
Sharif University of Technology
5 shared publications Arafeh Bigdeli
Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran; Department of Statistics, University of British Columbia, Vancouver, British Columbia, Canada
1 shared publicationAzad H. Alshatteri
Center for Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani, Qliasan Street, 46002, Sulaymaniyah City, Kurdistan, Iraq; Department of Chemistry, College of Education, University of Garmian, Darbandikhan Road, 46021, Kalar City, Sulaimaniyah Province, Iraq
1 shared publicationEnsieh Fahimi-Kashani
Malayer Int Univ, Fac Basic Sci, Hamadan, Iran
1 shared publication- Forough Ghasemi
Department of Nanotechnology, Agricultural Biotechnology Research Institute of Iran (ABRII), Agricultural Research, Education, and Extension Organization (AREEO), Karaj, Iran
1 shared publication - Khalid Mohammad Omer
Department of Chemistry, College of Science, University of Sulaimani, Qliasan St. 46002, Sulaymaniyah, Kurdistan Region, Iraq
1 shared publication
Latest Publications
- 16 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Multiplex detection of halide ions in Water: Feasibility of Optoelectronic Tongues using Au@Ag nanorod multicolor patterns
- 16 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Multiplex detection of halide ions in Water: Feasibility of Optoelectronic Tongues using Au@Ag nanorod multicolor patterns
- Open Access
- 1 April 2024
- Vol. 22 (2) , e3722
Recent Advances in Development of Biosensors for Monitoring of Airborne Microorganisms
Background: The early detection of infectious microorganisms is crucial for preventing and controlling the transmission of diseases. This article provides a comprehensive review of biosensors based on various diagnostic methods for measuring airborne pathogens. Objective: This article aims to explore recent advancements in the field of biosensors tailored for the detection and monitoring of airborne microorganisms, offering insights into emerging technologies and their potential applications in environmental surveillance and public health management. Materials and Methods: The study summarizes the research conducted on novel methods of detecting airborne microorganisms using different biological sensors, as well as the application of signal amplification technologies such as polymerase chain reaction (PCR), immunoassay reactions, molecular imprinted polymers (MIP) technique, lectin and cascade reactions, and nanomaterials. Results: Antibody and PCR detection methods are effective for specific microbial strains, but they have limitations including limited stability, high cost, and the need for skilled operators with basic knowledge of the target structure. Biosensors based on MIP and lectin offer a low-cost, stable, sensitive, and selective alternative to antibodies and PCR. However, challenges remain, such as the detection of small gas molecules by MIP and the lower sensitivity of lectins compared to antibodies. Additionally, achieving high sensitivity in complex environments poses difficulties for both methods. Conclusion: The development of sensitive, reliable, accessible, portable, and inexpensive biosensors holds great potential for clinical and environmental applications, including disease diagnosis, treatment monitoring, and point -of -care testing, offering a promising future in this field. This review presents an overview of biosensor detection principles, covering component identification, energy conversion principles, and signal amplification. Additionally, it summarizes the research and applications of biosensors in the detection of airborne microorganisms. The latest advancements and future trends in biosensor detection of airborne microorganisms are also analyzed.
- 1 April 2024
- Vol. 22 (2) , e3722
Open AccessRecent Advances in Development of Biosensors for Monitoring of Airborne Microorganisms
Background: The early detection of infectious microorganisms is crucial for preventing and controlling the transmission of diseases. This article provides a comprehensive review of biosensors based on various diagnostic methods for measuring airborne pathogens. Objective: This article aims to explore recent advancements in the field of biosensors tailored for the detection and monitoring of airborne microorganisms, offering insights into emerging technologies and their potential applications in environmental surveillance and public health management. Materials and Methods: The study summarizes the research conducted on novel methods of detecting airborne microorganisms using different biological sensors, as well as the application of signal amplification technologies such as polymerase chain reaction (PCR), immunoassay reactions, molecular imprinted polymers (MIP) technique, lectin and cascade reactions, and nanomaterials. Results: Antibody and PCR detection methods are effective for specific microbial strains, but they have limitations including limited stability, high cost, and the need for skilled operators with basic knowledge of the target structure. Biosensors based on MIP and lectin offer a low-cost, stable, sensitive, and selective alternative to antibodies and PCR. However, challenges remain, such as the detection of small gas molecules by MIP and the lower sensitivity of lectins compared to antibodies. Additionally, achieving high sensitivity in complex environments poses difficulties for both methods. Conclusion: The development of sensitive, reliable, accessible, portable, and inexpensive biosensors holds great potential for clinical and environmental applications, including disease diagnosis, treatment monitoring, and point -of -care testing, offering a promising future in this field. This review presents an overview of biosensor detection principles, covering component identification, energy conversion principles, and signal amplification. Additionally, it summarizes the research and applications of biosensors in the detection of airborne microorganisms. The latest advancements and future trends in biosensor detection of airborne microorganisms are also analyzed.
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (9) , 1123-1134
Machine-learning assisted multiplex detection of catecholamine neurotransmitters with a colorimetric sensor array
Catecholamine neurotransmitters (CNs), such as dopamine (DA), epinephrine (EP), norepinephrine (NEP), and levodopa (LD), are recognized as the primary biomarkers of a variety of neurological illnesses. Therefore, simultaneous monitoring of these biomarkers is highly recommended for clinical diagnosis and treatment. In this study, a high-performance colorimetric artificial tongue has been proposed for the multiplex detection of CNs. Different aggregation behaviors of gold nanoparticles in the presence of CNs under various buffering conditions generate unique fingerprint response patterns. Under various buffering conditions, the distinct acidity constants of CNs, and consequently their predominant species at a given pH, drive the aggregation of gold nanoparticles (AuNPs). The utilization of machine learning algorithms in this design enables classification and quantification of CNs in various samples. The response profile of the array was analyzed using the linear discriminant analysis algorithm for classification of CNs. This colorimetric sensor array is capable of accurately distinguishing between individual neurotransmitters and their combinations. Partial least squares regression was also applied for quantitation purposes. The obtained analytical figures of merit (FOMs) and linear ranges of 0.6–9 μM (R2 = 0.99) for DA, 0.1–10 μM (R2 = 0.99) for EP, 0.1–9 μM (R2 = 0.99) for NEP and 1–70 μM (R2 = 0.99) for LD demonstrated the potential applicability of the developed sensor array in precise and accurate determination of CNs. Finally, the feasibility of the array was validated in human urine samples as a complex biological fluid with LODs of 0.3, 0.5, 0.2, and 1.9 μM for DA, EP, NEP, and LD, respectively.
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (9) , 1123-1134
Machine-learning assisted multiplex detection of catecholamine neurotransmitters with a colorimetric sensor array
Catecholamine neurotransmitters (CNs), such as dopamine (DA), epinephrine (EP), norepinephrine (NEP), and levodopa (LD), are recognized as the primary biomarkers of a variety of neurological illnesses. Therefore, simultaneous monitoring of these biomarkers is highly recommended for clinical diagnosis and treatment. In this study, a high-performance colorimetric artificial tongue has been proposed for the multiplex detection of CNs. Different aggregation behaviors of gold nanoparticles in the presence of CNs under various buffering conditions generate unique fingerprint response patterns. Under various buffering conditions, the distinct acidity constants of CNs, and consequently their predominant species at a given pH, drive the aggregation of gold nanoparticles (AuNPs). The utilization of machine learning algorithms in this design enables classification and quantification of CNs in various samples. The response profile of the array was analyzed using the linear discriminant analysis algorithm for classification of CNs. This colorimetric sensor array is capable of accurately distinguishing between individual neurotransmitters and their combinations. Partial least squares regression was also applied for quantitation purposes. The obtained analytical figures of merit (FOMs) and linear ranges of 0.6–9 μM (R2 = 0.99) for DA, 0.1–10 μM (R2 = 0.99) for EP, 0.1–9 μM (R2 = 0.99) for NEP and 1–70 μM (R2 = 0.99) for LD demonstrated the potential applicability of the developed sensor array in precise and accurate determination of CNs. Finally, the feasibility of the array was validated in human urine samples as a complex biological fluid with LODs of 0.3, 0.5, 0.2, and 1.9 μM for DA, EP, NEP, and LD, respectively.
- 22 November 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1238, 340640
Paper-based optical nanosensors – A review
- 22 November 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1238, 340640
Paper-based optical nanosensors – A review
- 16 September 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1231, 340386
Toward visual chiral recognition of amino acids using a wide-range color tonality ratiometric nanoprobe
- 16 September 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1231, 340386
Toward visual chiral recognition of amino acids using a wide-range color tonality ratiometric nanoprobe