Antonios E. Papadakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Antonios E. Papadakis has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
John Damilakis
Medical Physics, University of Crete School of Medicine, Heraklion, Crete, GREECE
20 shared publicationsKostas Perisinakis
University of Crete, Medical School, Department of Medical Physics, Stavrakia, 71110 Heraklion, Crete, Greece
7 shared publications- John Damilakis
School of Medicine, University of Crete, Iraklion, Greece
4 shared publications - Thomas G. Maris
University of Crete
4 shared publications Apostolos H. Karantanas
University of Crete
2 shared publicationsGiorgos Papadokostakis
University Hospital of Heraklion
2 shared publications
Latest Publications
- Open Access
- 1 September 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (3) , 031514
Digital phantom versus individualised radiation dosimetry in CT examination protocols for children and adults
The aim of this study was to compare the organ doses estimated through individual model-based and digital phantom-based Monte Carlo (MC) methods in radiation treatment plan-oriented computed tomography (CT) examination protocols. Six physical anthropomorphic phantoms that simulate the average paediatric individual as a neonate, 1-year-old, 5-year-old or 10-year-old child and the average male or female adult individual were used. Organ dose was assessed using two MC-powered dosimetry tools: an individual model-based tool (ImpactMC, CT Imaging GmbH, Germany) and a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA). Normalised to volume CT dose index (CTDIvol) organ dose (nOD) was assessed for primarily exposed radiosensitive organs using head, thorax and abdomen/pelvis CT examination protocols intended for radiation treatment plans. nOD were compared with measurements performed using thermoluminescent detectors (TLDs) and physical anthropomorphic phantoms. The average per cent differences between ImpactMC and TLD measurements across all organs and phantoms were 8%, 20% and 16% for head, thorax and abdomen/pelvis, respectively, whereas the corresponding differences between NCICT and TLD measurements were 64%, 48% and 34%. The differences between estimated and measured normalised organ dose values were higher in paediatric than adult phantoms. Compared with NCICT, organ doses estimated with ImpactMC were in closer agreement with TLD measurements: this is due to the methodology employed by ImpactMC to create phantoms that mimic the anatomical characteristics of the examined patient.
- 1 September 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (3) , 031514
Open AccessDigital phantom versus individualised radiation dosimetry in CT examination protocols for children and adults
The aim of this study was to compare the organ doses estimated through individual model-based and digital phantom-based Monte Carlo (MC) methods in radiation treatment plan-oriented computed tomography (CT) examination protocols. Six physical anthropomorphic phantoms that simulate the average paediatric individual as a neonate, 1-year-old, 5-year-old or 10-year-old child and the average male or female adult individual were used. Organ dose was assessed using two MC-powered dosimetry tools: an individual model-based tool (ImpactMC, CT Imaging GmbH, Germany) and a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA). Normalised to volume CT dose index (CTDIvol) organ dose (nOD) was assessed for primarily exposed radiosensitive organs using head, thorax and abdomen/pelvis CT examination protocols intended for radiation treatment plans. nOD were compared with measurements performed using thermoluminescent detectors (TLDs) and physical anthropomorphic phantoms. The average per cent differences between ImpactMC and TLD measurements across all organs and phantoms were 8%, 20% and 16% for head, thorax and abdomen/pelvis, respectively, whereas the corresponding differences between NCICT and TLD measurements were 64%, 48% and 34%. The differences between estimated and measured normalised organ dose values were higher in paediatric than adult phantoms. Compared with NCICT, organ doses estimated with ImpactMC were in closer agreement with TLD measurements: this is due to the methodology employed by ImpactMC to create phantoms that mimic the anatomical characteristics of the examined patient.
- Open Access
- 22 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105092
A methodological approach for the comparison of CT systems in terms of radiation dose and image quality
- 22 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105092
Open AccessA methodological approach for the comparison of CT systems in terms of radiation dose and image quality
- Open Access
- 22 May 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (7) , e14389
Digital phantom versus patient‐specific radiation dosimetry in adult routine thorax CT examinations
Purpose: The aim of this study was to compare the organ doses assessed through a digital phantom‐based and a patient specific‐based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms.Methods: Two Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom‐based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient‐specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (Dw). Normalized to volume computed tomography dose index (CTDIvol), organ dose was assessed for lungs, esophagus, heart, breast, active bone marrow, and skin. Organ doses were compared to measurements performed using thermoluminescent detectors (TLDs) in two physical anthropomorphic phantoms that simulate the average adult individual as a male (Alderson Research Labs, USA) and as a female (ATOM Phantoms, USA).Results: The average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average ± 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was ± 0.06 (mGy/mGy), ± 0.19 (mGy/mGy), and ± 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing Dw in both NCICT and ImpactMC.Conclusion: Organ doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.
- 22 May 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (7) , e14389
Open AccessDigital phantom versus patient‐specific radiation dosimetry in adult routine thorax CT examinations
Purpose: The aim of this study was to compare the organ doses assessed through a digital phantom‐based and a patient specific‐based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms.Methods: Two Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom‐based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient‐specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (Dw). Normalized to volume computed tomography dose index (CTDIvol), organ dose was assessed for lungs, esophagus, heart, breast, active bone marrow, and skin. Organ doses were compared to measurements performed using thermoluminescent detectors (TLDs) in two physical anthropomorphic phantoms that simulate the average adult individual as a male (Alderson Research Labs, USA) and as a female (ATOM Phantoms, USA).Results: The average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average ± 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was ± 0.06 (mGy/mGy), ± 0.19 (mGy/mGy), and ± 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing Dw in both NCICT and ImpactMC.Conclusion: Organ doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.
- 1 September 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (3) , 031521
Implementation and evaluation of the AAPM TG 111 for radiation dosimetry in a state-of-the-art C-arm cone beam CT system
The aim of this study was to assess the dosimetric characteristics of a state-of-the-art C-arm cone beam computed tomography (CBCT) system using the methodology proposed by the American Association of Physicists in Medicine (AAPM) Task Group (TG) 111. The dose measurement methodology described in AAPM TG 111 for wide cone beam acquisitions without table translation was employed to estimate equilibrium beam length ( α eq ‾ ) and equilibrium dose ( f eq ‾ ) in various interventional task-specific protocols with different tube arc projection geometries. Dose profiles were derived from point dose measurements in the centre and peripheral locations of the ICRU/AAPM and standard polymethyl methacrylate (PMMA) body phantom. Dose measurements were performed in phantom and free-in-air using a solid-state point detector. Monte Carlo (MC) based simulation dosimetry was performed to quantify the inhomogeneous dose patterns imparted in the phantoms. Estimated α eq ‾ and f eq ‾ on the ICRU/AAPM phantom was up to 49.4 cm and 6.17 mGy/100 mAs, respectively. Corresponding values determined on the PMMA phantom were 139 cm and 8.8 mGy/100 mAs, respectively. Free-in-air dose measurement ranged from 1.43 mGy/100 mAs to 5.93 mGy/100 mAs. Per cent difference in α eq ‾ and f eq ‾ between MC simulation and solid-state point detector measurement methods in the ICRU/AAPM phantom were within 16% and 18%, respectively. Manufacturers can use the presented methodology to characterize the dosimetric properties of C-arm CBCT systems. Clinical medical physicists may follow this methodology to verify corresponding data provided by the manufacturer and check for C-arm CBCT system performance dosimetric consistency.
- 1 September 2023
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 43 (3) , 031521
Implementation and evaluation of the AAPM TG 111 for radiation dosimetry in a state-of-the-art C-arm cone beam CT system
The aim of this study was to assess the dosimetric characteristics of a state-of-the-art C-arm cone beam computed tomography (CBCT) system using the methodology proposed by the American Association of Physicists in Medicine (AAPM) Task Group (TG) 111. The dose measurement methodology described in AAPM TG 111 for wide cone beam acquisitions without table translation was employed to estimate equilibrium beam length ( α eq ‾ ) and equilibrium dose ( f eq ‾ ) in various interventional task-specific protocols with different tube arc projection geometries. Dose profiles were derived from point dose measurements in the centre and peripheral locations of the ICRU/AAPM and standard polymethyl methacrylate (PMMA) body phantom. Dose measurements were performed in phantom and free-in-air using a solid-state point detector. Monte Carlo (MC) based simulation dosimetry was performed to quantify the inhomogeneous dose patterns imparted in the phantoms. Estimated α eq ‾ and f eq ‾ on the ICRU/AAPM phantom was up to 49.4 cm and 6.17 mGy/100 mAs, respectively. Corresponding values determined on the PMMA phantom were 139 cm and 8.8 mGy/100 mAs, respectively. Free-in-air dose measurement ranged from 1.43 mGy/100 mAs to 5.93 mGy/100 mAs. Per cent difference in α eq ‾ and f eq ‾ between MC simulation and solid-state point detector measurement methods in the ICRU/AAPM phantom were within 16% and 18%, respectively. Manufacturers can use the presented methodology to characterize the dosimetric properties of C-arm CBCT systems. Clinical medical physicists may follow this methodology to verify corresponding data provided by the manufacturer and check for C-arm CBCT system performance dosimetric consistency.
- 13 June 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (10) , 2060-2068
The effect of added filtration on radiation dose and image quality in digital radiography of newborns
Background Repeated chest and/or abdomen radiographs are needed on mobile digital radiography (DR) units to assess infants’ health status. Optimization of DR tube peak kilovoltage (kVp) and tube current time product (mAs) to derive images of diagnostic quality at as low as reasonably achievable radiation dose has been a challenging task. Objective To investigate the effect of exposure parameters and additional filtration on entrance skin dose and image quality in newborn DR imaging. Materials and methods A physical anthropomorphic phantom that simulates the average full-term neonate was used. Chest and chest/abdomen DR images were acquired at the manufacturer’s recommended kVp/mAs exposure parameters followed by a series of image acquisitions at different kVp/mAs and beam filtration combinations. Entrance skin dose (ESD) and signal difference to noise ratio (SdNR) for soft tissue, bone and feeding gastric tube were estimated in raw unprocessed images. A figure of merit (FOM) analysis provided the kVp/mAs and filtration that generated images of adequate quality at the lowest ESD. Results Signal difference increased with kVp and progressively decreased with increasing filtration. Compared to the manufacturer’s recommended 53 kVp/1.6 mAs exposure parameters, ESD was reduced by 76% (47.61 μGy versus 11.3 μGy) in the chest and 66% (47.61 μGy versus 16.14 μGy) in the chest/abdomen when the exposure parameters and additional beam filtration provided by the FOM analysis were used. Conclusion The results derived from this phantom study suggest that additional beam filtration along with the appropriate leverage of exposure parameters can lower ESD while maintaining image quality in full-term newborns. Graphical Abstract
- 13 June 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (10) , 2060-2068
The effect of added filtration on radiation dose and image quality in digital radiography of newborns
Background Repeated chest and/or abdomen radiographs are needed on mobile digital radiography (DR) units to assess infants’ health status. Optimization of DR tube peak kilovoltage (kVp) and tube current time product (mAs) to derive images of diagnostic quality at as low as reasonably achievable radiation dose has been a challenging task. Objective To investigate the effect of exposure parameters and additional filtration on entrance skin dose and image quality in newborn DR imaging. Materials and methods A physical anthropomorphic phantom that simulates the average full-term neonate was used. Chest and chest/abdomen DR images were acquired at the manufacturer’s recommended kVp/mAs exposure parameters followed by a series of image acquisitions at different kVp/mAs and beam filtration combinations. Entrance skin dose (ESD) and signal difference to noise ratio (SdNR) for soft tissue, bone and feeding gastric tube were estimated in raw unprocessed images. A figure of merit (FOM) analysis provided the kVp/mAs and filtration that generated images of adequate quality at the lowest ESD. Results Signal difference increased with kVp and progressively decreased with increasing filtration. Compared to the manufacturer’s recommended 53 kVp/1.6 mAs exposure parameters, ESD was reduced by 76% (47.61 μGy versus 11.3 μGy) in the chest and 66% (47.61 μGy versus 16.14 μGy) in the chest/abdomen when the exposure parameters and additional beam filtration provided by the FOM analysis were used. Conclusion The results derived from this phantom study suggest that additional beam filtration along with the appropriate leverage of exposure parameters can lower ESD while maintaining image quality in full-term newborns. Graphical Abstract
- 12 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 46-54
Assessment of abdominal organ dose and image quality in varying arc trajectory interventional C-arm cone beam CT
- 12 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 46-54
Assessment of abdominal organ dose and image quality in varying arc trajectory interventional C-arm cone beam CT
- 2 April 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (9) , 5790-5798
Organ doses and normalized organ doses for various age groups in ultralow dose pediatric C-arm cone-beam CT
Objectives To estimate organ dose to major radiosensitive organs during pediatric body C-arm CBCT and determine normalized organ doses using a state-of-the-art equipment. Methods This is a study performed utilizing physical anthropomorphic phantoms. Four anthropomorphic phantoms that simulate the average individual as a neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Personalized Monte Carlo (MC)–based dosimetry was performed to estimate organ doses in children referred to thorax and abdomen C-arm CBCT acquisitions on a recently released latest generation C-arm CBCT system. Age-specific normalized organ doses were generated and organ dose was estimated for skin, bone, breast, lungs, esophagus, thymus, and heart, in the thorax, and liver, adrenals, kidneys, pancreas, stomach, gall bladder, and spleen in the abdomen. Estimated doses were compared to corresponding values obtained with physical measurements performed using thermoluminescent dosimeters (TLD). Results The results consist of organ doses for thorax and abdomen acquisition protocols. The majority of organs received a dose below 1 mSv. For all ages, the normalized organ doses decreased from neonate to 10-year-old. The difference between the organ doses obtained with MC and TLDs was less than 8%. Conclusions Normalized organ doses in pediatric C-arm CBCT varied with age. Pediatric C-arm CBCT with latest-generation systems may be performed with sub mGy dose for most organs. Key Points • The dose to the majority of organs from pediatric C-arm CBCT is in the sub mSv level. • The normalized organ doses decreased from neonate to 10-year-old. • Reported normalized organ doses may be used to estimate organ dose in pediatric C-arm cone-beam CT on modern equipment.
- 2 April 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (9) , 5790-5798
Organ doses and normalized organ doses for various age groups in ultralow dose pediatric C-arm cone-beam CT
Objectives To estimate organ dose to major radiosensitive organs during pediatric body C-arm CBCT and determine normalized organ doses using a state-of-the-art equipment. Methods This is a study performed utilizing physical anthropomorphic phantoms. Four anthropomorphic phantoms that simulate the average individual as a neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Personalized Monte Carlo (MC)–based dosimetry was performed to estimate organ doses in children referred to thorax and abdomen C-arm CBCT acquisitions on a recently released latest generation C-arm CBCT system. Age-specific normalized organ doses were generated and organ dose was estimated for skin, bone, breast, lungs, esophagus, thymus, and heart, in the thorax, and liver, adrenals, kidneys, pancreas, stomach, gall bladder, and spleen in the abdomen. Estimated doses were compared to corresponding values obtained with physical measurements performed using thermoluminescent dosimeters (TLD). Results The results consist of organ doses for thorax and abdomen acquisition protocols. The majority of organs received a dose below 1 mSv. For all ages, the normalized organ doses decreased from neonate to 10-year-old. The difference between the organ doses obtained with MC and TLDs was less than 8%. Conclusions Normalized organ doses in pediatric C-arm CBCT varied with age. Pediatric C-arm CBCT with latest-generation systems may be performed with sub mGy dose for most organs. Key Points • The dose to the majority of organs from pediatric C-arm CBCT is in the sub mSv level. • The normalized organ doses decreased from neonate to 10-year-old. • Reported normalized organ doses may be used to estimate organ dose in pediatric C-arm cone-beam CT on modern equipment.
- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 75-81
The effect of tube focal spot size and acquisition mode on task-based image quality performance of a GE revolution HD dual energy CT scanner
- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 75-81
The effect of tube focal spot size and acquisition mode on task-based image quality performance of a GE revolution HD dual energy CT scanner
- 1 June 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (6) , 807-812
Discrimination of High-Risk Type-2 Endoleak after Endovascular Aneurysm Repair through CT Perfusion: A Feasibility Study
- 1 June 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (6) , 807-812
Discrimination of High-Risk Type-2 Endoleak after Endovascular Aneurysm Repair through CT Perfusion: A Feasibility Study
- 1 February 2021
- Published by Elsevier in Physica Medica
- Vol. 82, 114-121
Technical Note: Quality assessment of virtual monochromatic spectral images on a dual energy CT scanner
- 1 February 2021
- Published by Elsevier in Physica Medica
- Vol. 82, 114-121
Technical Note: Quality assessment of virtual monochromatic spectral images on a dual energy CT scanner