Yanjun Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanjun Liu has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Jie Tian
Beihang University
13 shared publications - Hui Hui
Chinese Academy of Sciences
8 shared publications - Xin Feng
Institute of Automation
6 shared publications - Lei Li
School of Life Science and Technology, Xidian University, Xian, China
5 shared publications - Yu An
Beihang University
5 shared publications - Guanghui Li
School of Engineering Medicine and the School of Biological Science and Medical Engineering, Beihang University, Beijing, China
3 shared publications
Latest Publications
- 5 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 3216-3228
Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique
Magnetic Particle Imaging (MPI) enables noninvasive temperature imaging without depth limitations. However, due to the lack of effective calibration strategies that can simultaneously address issues such as calibration infeasibility and environmental mismatch, its practical in vivo application remains challenging. In this work, we propose a novel in vivo temperature imaging method based on a dual-mode magnetic particle spectroscopy/magnetic particle imaging (MPS/MPI) system. First, MPS is employed to capture the differences in harmonic phase responses of magnetic nanoparticles (MNPs) under in vivo and in vitro conditions, thereby enabling the construction of calibration functions that are consistent with the in vivo environment. Second, an MLP based calibration strategy is proposed, which accounts for non-ideal deviations from the approximately linear temperature–phase relationship and integrates multi-parameter information into a unified network, thereby enabling accurate and stable temperature mapping. Comprehensive simulation, in vitro, and in vivo experiments demonstrate that, compared with conventional phantom-based temperature mapping methods, the proposed method reduces the in vivo temperature reconstruction error by approximately 17.24% and achieves an average absolute temperature error below 1.257 °C. These results verify the feasibility of accurate in vivo temperature imaging using MPI and provide essential technical support for temperature-sensitive applications, including magnetic hyperthermia.
- 5 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 3216-3228
Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique
Magnetic Particle Imaging (MPI) enables noninvasive temperature imaging without depth limitations. However, due to the lack of effective calibration strategies that can simultaneously address issues such as calibration infeasibility and environmental mismatch, its practical in vivo application remains challenging. In this work, we propose a novel in vivo temperature imaging method based on a dual-mode magnetic particle spectroscopy/magnetic particle imaging (MPS/MPI) system. First, MPS is employed to capture the differences in harmonic phase responses of magnetic nanoparticles (MNPs) under in vivo and in vitro conditions, thereby enabling the construction of calibration functions that are consistent with the in vivo environment. Second, an MLP based calibration strategy is proposed, which accounts for non-ideal deviations from the approximately linear temperature–phase relationship and integrates multi-parameter information into a unified network, thereby enabling accurate and stable temperature mapping. Comprehensive simulation, in vitro, and in vivo experiments demonstrate that, compared with conventional phantom-based temperature mapping methods, the proposed method reduces the in vivo temperature reconstruction error by approximately 17.24% and achieves an average absolute temperature error below 1.257 °C. These results verify the feasibility of accurate in vivo temperature imaging using MPI and provide essential technical support for temperature-sensitive applications, including magnetic hyperthermia.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1404-1418
Semi-Analytical Super-Resolution X-Space Reconstruction for Magnetic Particle Imaging Scanner via Adaptive Kernel Optimization
Magnetic Particle Imaging (MPI) is an emerging biomedical imaging technique. The x-space method, one of the mainstream reconstruction methods in MPI, offers high efficiency and real-time capabilities but is limited by theoretical spatial resolution constraints and typically necessitates high gradient magnetic fields. This study introduces a semi-analytical reconstruction (Semi-AR) method for x-space MPI scanner, incorporating a kernel optimization step to achieve a spatial resolution better than the theoretical limit. By modeling the xspace MPI system with focus-field sequences as a linear shift invariant system, the point spread function (PSF) is decomposed into basis functions and variants across different spatial frequencies. These functions are weighted to reconstruct a highresolution PSF, with optimal weights adaptively determined via quadratic programming. A mouse-sized MPI scanner with 3D focus-field sequences was developed to evaluate the method. Simulation and experimental results showcase Semi-AR's superior spatial resolution and robustness compared to existing x-space techniques, particularly in detecting low-brightness targets near highlighted non-target organs. Both phantom and in vivo experiments robustly validate Semi-AR's effectiveness, providing new insights into MPI scanner development, and advancing preclinical and potential clinical MPI applications.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1404-1418
Semi-Analytical Super-Resolution X-Space Reconstruction for Magnetic Particle Imaging Scanner via Adaptive Kernel Optimization
Magnetic Particle Imaging (MPI) is an emerging biomedical imaging technique. The x-space method, one of the mainstream reconstruction methods in MPI, offers high efficiency and real-time capabilities but is limited by theoretical spatial resolution constraints and typically necessitates high gradient magnetic fields. This study introduces a semi-analytical reconstruction (Semi-AR) method for x-space MPI scanner, incorporating a kernel optimization step to achieve a spatial resolution better than the theoretical limit. By modeling the xspace MPI system with focus-field sequences as a linear shift invariant system, the point spread function (PSF) is decomposed into basis functions and variants across different spatial frequencies. These functions are weighted to reconstruct a highresolution PSF, with optimal weights adaptively determined via quadratic programming. A mouse-sized MPI scanner with 3D focus-field sequences was developed to evaluate the method. Simulation and experimental results showcase Semi-AR's superior spatial resolution and robustness compared to existing x-space techniques, particularly in detecting low-brightness targets near highlighted non-target organs. Both phantom and in vivo experiments robustly validate Semi-AR's effectiveness, providing new insights into MPI scanner development, and advancing preclinical and potential clinical MPI applications.
- Open Access
- 1 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (31) , eadv2485
Magnetically induced magnetosome chain (MAGiC): A biogenic magnetic-particle-imaging tracer with high performance and navigability
Magnetic particle imaging (MPI) enables real-time, sensitive, and quantitative visualization of tracer distribution, augmenting the capability of in vivo imaging technologies. Previous MPI tracer research has predominantly focused on superparamagnetic nanoparticles, whose suboptimal sigmoidal magnetization curves limit their spatial resolution. Here, we introduce the magnetically induced magnetosome chain (MAGiC), a superferromagnetic MPI tracer, demonstrating a 25-fold improvement in resolution in the excitation direction and an order of magnitude improvement in signal intensity compared to the commercial tracer VivoTrax+. Under a gradient field of 4 tesla per meter, the resolution in the excitation direction reached 80 micrometers. Furthermore, MAGiC can be accurately manipulated using magnetic fields, making it an MPI-trackable microrobot. We have elucidated the mechanisms underlying MAGiC’s superior performance and validated its effectiveness in vitro and in vivo. As a high-performance MPI tracer and microrobot, MAGiC holds tremendous potential for various applications, such as cell tracking, image-guided drug delivery, and therapeutic interventions.
- 1 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (31) , eadv2485
Open AccessMagnetically induced magnetosome chain (MAGiC): A biogenic magnetic-particle-imaging tracer with high performance and navigability
Magnetic particle imaging (MPI) enables real-time, sensitive, and quantitative visualization of tracer distribution, augmenting the capability of in vivo imaging technologies. Previous MPI tracer research has predominantly focused on superparamagnetic nanoparticles, whose suboptimal sigmoidal magnetization curves limit their spatial resolution. Here, we introduce the magnetically induced magnetosome chain (MAGiC), a superferromagnetic MPI tracer, demonstrating a 25-fold improvement in resolution in the excitation direction and an order of magnitude improvement in signal intensity compared to the commercial tracer VivoTrax+. Under a gradient field of 4 tesla per meter, the resolution in the excitation direction reached 80 micrometers. Furthermore, MAGiC can be accurately manipulated using magnetic fields, making it an MPI-trackable microrobot. We have elucidated the mechanisms underlying MAGiC’s superior performance and validated its effectiveness in vitro and in vivo. As a high-performance MPI tracer and microrobot, MAGiC holds tremendous potential for various applications, such as cell tracking, image-guided drug delivery, and therapeutic interventions.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 1692-1705
Relaxation-Based Super-Resolution Method in Pulsed Magnetic Particle Imaging
Spatial resolution is one of the most critical indicators for magnetic particle imaging (MPI). Due to factors such as relaxation effects and suboptimal magnetization response, MPI has not yet reached the promised spatial resolution. Pulsed MPI is a method that enables MPI to achieve the resolution predicted by the Langevin function, which thereby enables larger magnetic particles (MNPs) to enhance resolution. To further exceed this resolution, we propose a relaxation-based super-resolution method which leverages the principle that MNPs at different positions exhibit varying relaxation times due to the different DC fields provided by the gradient field. This principle allows the super-resolution method to extract signals from the center of the field free region (FFR) to enhance spatial resolution. The super-resolution method first truncates the exponential decay signal during the plateau phase of the excitation field. Then, the truncated signals are decomposed based on their relaxation times. Finally, signals from the center position of the FFR are retained, and signals from the periphery of the FFR are discarded. Using this retained signal for reconstruction results in a higher spatial resolution. We validate this method via both simulation and experimental measurements. The results indicate that, compared with sinusoidal MPI and pulsed MPI without super-resolution, the super-resolution method has two-fold improvement in resolution.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 1692-1705
Relaxation-Based Super-Resolution Method in Pulsed Magnetic Particle Imaging
Spatial resolution is one of the most critical indicators for magnetic particle imaging (MPI). Due to factors such as relaxation effects and suboptimal magnetization response, MPI has not yet reached the promised spatial resolution. Pulsed MPI is a method that enables MPI to achieve the resolution predicted by the Langevin function, which thereby enables larger magnetic particles (MNPs) to enhance resolution. To further exceed this resolution, we propose a relaxation-based super-resolution method which leverages the principle that MNPs at different positions exhibit varying relaxation times due to the different DC fields provided by the gradient field. This principle allows the super-resolution method to extract signals from the center of the field free region (FFR) to enhance spatial resolution. The super-resolution method first truncates the exponential decay signal during the plateau phase of the excitation field. Then, the truncated signals are decomposed based on their relaxation times. Finally, signals from the center position of the FFR are retained, and signals from the periphery of the FFR are discarded. Using this retained signal for reconstruction results in a higher spatial resolution. We validate this method via both simulation and experimental measurements. The results indicate that, compared with sinusoidal MPI and pulsed MPI without super-resolution, the super-resolution method has two-fold improvement in resolution.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Peak Shift in Field-Swept Magnetic Particle Spectroscopy: A Novel Sensing Metric for Magnetic Nanoparticle Bioassays
Combining magnetic particle spectroscopy (MPS) with functionalized magnetic nanoparticles (MNPs) has the potential to provide a rapid, sensitive, and user-friendly point-of-care testing platform. Conventional MPS techniques typically apply harmonic ratios (such as, third to fifth harmonic ratio) as the sensing metric to eliminate interference caused by MNP concentration. However, the quantification accuracy of this approach largely depends on the consistency of the signal-to-noise ratio between the selected harmonics, imposing stringent requirements on hardware design and the nonlinear magnetic behavior of the MNPs. In this study, we introduce "peak shift" to field-swept magnetic particle spectroscopy (FS-MPS) as a novel metric for MNP characterization and biosensing. An integrated FS-MPS device is used to capture the second harmonic spectrum, which records the second harmonic amplitudes under different perpendicular static magnetic fields. Importantly, the peak position of the spectrum remains constant under different MNP concentrations and shifts upon changes in MNP hydrodynamic size. In this way, the peak shift sensitively detects MNP binding to the targeted analytes, enabling robust biosensing based solely on the second harmonics. The feasibility of the proposed method was demonstrated using streptavidin-grafted MNPs and biotinylated polystyrene beads. Diagnostic performance was assessed using ACE2 functionalized MNPs and SARS-CoV-2 S1 protein and SARS-CoV-2 pseudovirus assays. The proposed strategy can detect virus concentrations as low as 350 TCID 50 /mL. Additionally, a good linear correlation exists between the peak shift and virus titer in the 350–7000 TCID 50 /mL range, demonstrating the potential of our method to quantify virus content.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Peak Shift in Field-Swept Magnetic Particle Spectroscopy: A Novel Sensing Metric for Magnetic Nanoparticle Bioassays
Combining magnetic particle spectroscopy (MPS) with functionalized magnetic nanoparticles (MNPs) has the potential to provide a rapid, sensitive, and user-friendly point-of-care testing platform. Conventional MPS techniques typically apply harmonic ratios (such as, third to fifth harmonic ratio) as the sensing metric to eliminate interference caused by MNP concentration. However, the quantification accuracy of this approach largely depends on the consistency of the signal-to-noise ratio between the selected harmonics, imposing stringent requirements on hardware design and the nonlinear magnetic behavior of the MNPs. In this study, we introduce "peak shift" to field-swept magnetic particle spectroscopy (FS-MPS) as a novel metric for MNP characterization and biosensing. An integrated FS-MPS device is used to capture the second harmonic spectrum, which records the second harmonic amplitudes under different perpendicular static magnetic fields. Importantly, the peak position of the spectrum remains constant under different MNP concentrations and shifts upon changes in MNP hydrodynamic size. In this way, the peak shift sensitively detects MNP binding to the targeted analytes, enabling robust biosensing based solely on the second harmonics. The feasibility of the proposed method was demonstrated using streptavidin-grafted MNPs and biotinylated polystyrene beads. Diagnostic performance was assessed using ACE2 functionalized MNPs and SARS-CoV-2 S1 protein and SARS-CoV-2 pseudovirus assays. The proposed strategy can detect virus concentrations as low as 350 TCID 50 /mL. Additionally, a good linear correlation exists between the peak shift and virus titer in the 350–7000 TCID 50 /mL range, demonstrating the potential of our method to quantify virus content.
- Open Access
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
First Nonhuman Primate-Sized Magnetic Particle Imaging System Based on Digital-Scanned Focus Field
Magnetic particle imaging (MPI) is a burgeoning imaging modality that facilitates the reconstruction of position and concentration of superparamagnetic iron oxide nanoparticles. Its potential in clinical applications is substantial, leading to an increasing demand for larger bore sizes in MPI systems. However, the challenge lies in maintaining high resolution, sensitivity, and real-time imaging advantages in larger systems. In this article, we present the design of a three-dimensional (3D) MPI system tailored for non-human primates (NHP-MPI) with a bore size of 190 mm. The application of a 3D digital-scanned focus field is applied to obtain highly sensitive imaging, and the system operates cooling-free under low gradient conditions. In imaging experiments involving a macaque’s brain, our system demonstrated good quantitative performance. The 3D MPI image yielded satisfactory results for fusion with other structural imaging modalities.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Open AccessFirst Nonhuman Primate-Sized Magnetic Particle Imaging System Based on Digital-Scanned Focus Field
Magnetic particle imaging (MPI) is a burgeoning imaging modality that facilitates the reconstruction of position and concentration of superparamagnetic iron oxide nanoparticles. Its potential in clinical applications is substantial, leading to an increasing demand for larger bore sizes in MPI systems. However, the challenge lies in maintaining high resolution, sensitivity, and real-time imaging advantages in larger systems. In this article, we present the design of a three-dimensional (3D) MPI system tailored for non-human primates (NHP-MPI) with a bore size of 190 mm. The application of a 3D digital-scanned focus field is applied to obtain highly sensitive imaging, and the system operates cooling-free under low gradient conditions. In imaging experiments involving a macaque’s brain, our system demonstrated good quantitative performance. The 3D MPI image yielded satisfactory results for fusion with other structural imaging modalities.
- 22 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108783
Dual-channel end-to-end network with prior knowledge embedding for improving spatial resolution of magnetic particle imaging
- 22 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108783
Dual-channel end-to-end network with prior knowledge embedding for improving spatial resolution of magnetic particle imaging
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (10) , 2889-2899
Space-Specific Mixing Excitation for High-SNR Spatial Encoding in Magnetic Particle Imaging
Objective: Magnetic Particle Imaging (MPI) is a radiation-free tracer-based imaging technology that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. Conventional spatial encoding methods in MPI rely on a gradient magnetic field with a constant gradient strength to generate a field-free point or line for spatial scanning. However, increasing the gradient strength can enhance theoretical spatial resolution but also lead to a decrease in the Signal-to-Noise Ratio (SNR) and sensitivity of the imaging system. This poses a technical challenge in balancing spatial resolution and sensitivity, necessitating intricate hardware design. Methods: To address this, we present a Space-Specific Mixing Excitation (SSME) technique for achieving high-SNR spatial encoding in MPI. By utilizing a dual-frequency excitation magnetic field with a non-homogeneous field strength, magnetic particles at each position generate unique intermodulation responses. By performing multi-channel acquisitions across the entire field of view, high SNR MPI signals can be acquired. When combined with reconstruction techniques based on system matrix, multi-dimensional SSME-MPI can be achieved. Results: The effectiveness of the proposed method was validated through phantom and in vivo imaging experiments. The results demonstrate significant improvements in sensitivity (3.6-fold improvement) and spatial resolution (better than 1 mm) without any hardware modifications. Conclusion: These findings demonstrate the capability of SSME to enhance both the spatial resolution and sensitivity of MPI. Significance: This method provides a solution to the ongoing challenge of balancing spatial resolution and sensitivity in MPI, potentially facilitating the implementation of MPI in a wider range of medical applications.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (10) , 2889-2899
Space-Specific Mixing Excitation for High-SNR Spatial Encoding in Magnetic Particle Imaging
Objective: Magnetic Particle Imaging (MPI) is a radiation-free tracer-based imaging technology that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. Conventional spatial encoding methods in MPI rely on a gradient magnetic field with a constant gradient strength to generate a field-free point or line for spatial scanning. However, increasing the gradient strength can enhance theoretical spatial resolution but also lead to a decrease in the Signal-to-Noise Ratio (SNR) and sensitivity of the imaging system. This poses a technical challenge in balancing spatial resolution and sensitivity, necessitating intricate hardware design. Methods: To address this, we present a Space-Specific Mixing Excitation (SSME) technique for achieving high-SNR spatial encoding in MPI. By utilizing a dual-frequency excitation magnetic field with a non-homogeneous field strength, magnetic particles at each position generate unique intermodulation responses. By performing multi-channel acquisitions across the entire field of view, high SNR MPI signals can be acquired. When combined with reconstruction techniques based on system matrix, multi-dimensional SSME-MPI can be achieved. Results: The effectiveness of the proposed method was validated through phantom and in vivo imaging experiments. The results demonstrate significant improvements in sensitivity (3.6-fold improvement) and spatial resolution (better than 1 mm) without any hardware modifications. Conclusion: These findings demonstrate the capability of SSME to enhance both the spatial resolution and sensitivity of MPI. Significance: This method provides a solution to the ongoing challenge of balancing spatial resolution and sensitivity in MPI, potentially facilitating the implementation of MPI in a wider range of medical applications.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 196-207
Spatial-Frequency Multi-Scale Transformer for Deblurring and Shape-Preserving Reconstruction in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a novel and emerging functional imaging technique that visualizes the spatial distribution of magnetic nanoparticles (MNPs). While the X-space method considers some important physical properties of MPI systems, it also neglects some phenomena, such as signals generated by MNPs outside (but close-to) the field-free region. Therefore, the X-space approach often results in blurring artifacts and incomplete edge information in native MPI images. In this study, we propose a spatial-frequency multi-scale transformer (SFM-Transformer) to address this limitation by restoring both the spatial and frequency domain features of the native image. SFM-Transformer comprises three modules: the spatial and frequency feature extractor module (SFFE), the spatial and frequency fusion module (SFF), and the multi-scale fusion module (MSF). By incorporating cross-feature space dependencies and capturing long-range details in spatial and frequency domains, our network captures pixel-level features and implicit physical properties features of native images. Furthermore, the SFM-Transformer utilizes a multi-scale strategy at the backbone to further improve performance. To facilitate comprehensive research, we construct a diverse dataset containing both simulated and experimental datasets. To validate the effectiveness of our method, we conduct extensive experiments in simulated and experimental data. The experimental results demonstrate that our method eliminates the blurring artifacts and recovers the edge shape of MPI images. This suggests that our approach has great potential for improving the accuracy and reliability of MPI for future applications.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 196-207
Spatial-Frequency Multi-Scale Transformer for Deblurring and Shape-Preserving Reconstruction in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a novel and emerging functional imaging technique that visualizes the spatial distribution of magnetic nanoparticles (MNPs). While the X-space method considers some important physical properties of MPI systems, it also neglects some phenomena, such as signals generated by MNPs outside (but close-to) the field-free region. Therefore, the X-space approach often results in blurring artifacts and incomplete edge information in native MPI images. In this study, we propose a spatial-frequency multi-scale transformer (SFM-Transformer) to address this limitation by restoring both the spatial and frequency domain features of the native image. SFM-Transformer comprises three modules: the spatial and frequency feature extractor module (SFFE), the spatial and frequency fusion module (SFF), and the multi-scale fusion module (MSF). By incorporating cross-feature space dependencies and capturing long-range details in spatial and frequency domains, our network captures pixel-level features and implicit physical properties features of native images. Furthermore, the SFM-Transformer utilizes a multi-scale strategy at the backbone to further improve performance. To facilitate comprehensive research, we construct a diverse dataset containing both simulated and experimental datasets. To validate the effectiveness of our method, we conduct extensive experiments in simulated and experimental data. The experimental results demonstrate that our method eliminates the blurring artifacts and recovers the edge shape of MPI images. This suggests that our approach has great potential for improving the accuracy and reliability of MPI for future applications.
- Open Access
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8 (2) , 1322-1336
BSS-TFNet: Attention-Enhanced Background Signal Suppression Network for Time-Frequency Spectrum in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality, which uses the nonlinear response of superparamagnetic iron oxide nanoparticles to the applied magnetic field to image their spatial distribution. Background signal is the main source of artifacts in MPI, which mainly includes harmonic interference and Gaussian noise. For different sources of noise, the existing methods directly process the time domain signal to achieve signal enhancement or construct system function by frequency domain signal to obtain high-quality reconstructed images. However, due to the randomness and variety of the background signal, the existing methods fail to eliminate all kinds of noise at the same time, especially when the noise is nonlinear. In this work, we proposed a deep learning method adopting self-attention mechanism, which can effectively suppress different levels of harmonic interference and Gaussian noise simultaneously. Our method deals with the two-dimensional time-frequency spectrum acquired by short-time Fourier transform from the temporal signal, learning global features and local features between time and frequency domain through the network, to achieve the purpose of reducing background noise. The performance of our method is analyzed via simulation experiments and imaging experiments performed with an in-house MPI scanner, which shows that our method can effectively suppress background signals and obtain high-quality MPI images.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8 (2) , 1322-1336
Open AccessBSS-TFNet: Attention-Enhanced Background Signal Suppression Network for Time-Frequency Spectrum in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality, which uses the nonlinear response of superparamagnetic iron oxide nanoparticles to the applied magnetic field to image their spatial distribution. Background signal is the main source of artifacts in MPI, which mainly includes harmonic interference and Gaussian noise. For different sources of noise, the existing methods directly process the time domain signal to achieve signal enhancement or construct system function by frequency domain signal to obtain high-quality reconstructed images. However, due to the randomness and variety of the background signal, the existing methods fail to eliminate all kinds of noise at the same time, especially when the noise is nonlinear. In this work, we proposed a deep learning method adopting self-attention mechanism, which can effectively suppress different levels of harmonic interference and Gaussian noise simultaneously. Our method deals with the two-dimensional time-frequency spectrum acquired by short-time Fourier transform from the temporal signal, learning global features and local features between time and frequency domain through the network, to achieve the purpose of reducing background noise. The performance of our method is analyzed via simulation experiments and imaging experiments performed with an in-house MPI scanner, which shows that our method can effectively suppress background signals and obtain high-quality MPI images.