BZBo Zhang

Bo Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo Zhang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic Field Strength Encoded Handheld Magnetic Particle Imaging System With Multiwaveform Excitation

    by Bo Zhang, Haoran Zhang, Pengli Gao, Hui Hui, Yu An, Jie Tian

    Magnetic Particle Imaging (MPI) is an innovative medical imaging modality with tremendous potential for various clinical applications. The handheld MPI device, due to its high biosafety and portability, holds promise for use in intraoperative diagnosis and other clinical settings. The handheld MPI system has all its hardware components located on one side of the imaged object, enabling convenient mobile detection. However, this single-sided construction leads to a reduced magnetic field gradient of the selection field, resulting in compromised imaging field of view (FOV) and resolution. To address these challenges, this study proposes a handheld MPI system that utilizes excitation field intensity encoding. By gradually increasing the calibrated excitation field, spatial encoding is achieved throughout the FOV. To improve the imaging resolution of the system, three different excitation waveforms are applied to the excitation coil to expand the available harmonic signals. Additionally, a bidirectional adjustable external compensation strategy is introduced to achieve more precise direct feedthrough suppression, restoring the baseband signal. Experimental results demonstrate that the proposed handheld MPI achieves a spatial resolution of 1 mm within a depth range of 30 mm, while maintaining imaging FOV, resolution, and a detection sensitivity of 50 ng Fe, laying a foundation for future clinical applications.


  • A Novel Hand-Held Multi-Color Magnetic Particle Imaging Device Based on Rapid Frequency Conversion

    by Haoran Zhang, Bo Zhang, Jiaqian Li, Guangxing Zhou, Siao Lei, Yu An, Jie Tian

    Objective: Multi-color Magnetic Particle Imaging (MPI) technology offers high sensitivity and non-invasive imaging capabilities. It can simultaneously image multiple superparamagnetic iron oxide nanoparticles (SPIOs), facilitating more precise detection of multiple molecular markers in vivo. However, the fixed drive frequency of existing hand-held MPI devices makes it difficult to fully match the nonlinear magnetic response of different SPIOs, affecting the spatial resolution and quantitative accuracy of multi-color imaging. Methods: We designed a novel rapid frequency conversion based hand-held multi-color magnetic particle imaging (RFC-MPI) device. This device adjusts the drive frequency based on the nonlinear magnetic response of SPIOs at different frequencies, effectively expanding the system matrix information and thereby improving spatial resolution and multi-color imaging capabilities simultaneously. Results: The device achieved a spatial resolution of 2 mm and an imaging speed of 1 frame/s. The scanning depth is 8 mm. It was used to scan a 22 cm x 22 cm area of a human-shaped phantom, verifying its potential for scanning humans. The ability of the device to identify and quantify SPIOs was validated using mice breast tumors. The quantitative accuracy during simultaneous imaging was determined to be 96.58%. Conclusion: Due to its innovative structural design and rapid frequency conversion method, the RFC-MPI device exhibits excellent in vivo imaging performance. Both simulation and phantom experiments have verified the effectiveness of the proposed method. Significance: The hand-held RFC-MPI device can effectively improve the spatial resolution and quantitative accuracy of multi-color MPI, laying the foundation for future clinical applications.


  • Open Access

    First Nonhuman Primate-Sized Magnetic Particle Imaging System Based on Digital-Scanned Focus Field

    by Zechen Wei, Yanjun Liu, Sijia Liu, Xiaomei Yu, Haoran Zhang, Tao Zhu, Bo Zhang, Yali Zhang, Hongdi Huang, Yang Fan, et al.

    Magnetic particle imaging (MPI) is a burgeoning imaging modality that facilitates the reconstruction of position and concentration of superparamagnetic iron oxide nanoparticles. Its potential in clinical applications is substantial, leading to an increasing demand for larger bore sizes in MPI systems. However, the challenge lies in maintaining high resolution, sensitivity, and real-time imaging advantages in larger systems. In this article, we present the design of a three-dimensional (3D) MPI system tailored for non-human primates (NHP-MPI) with a bore size of 190 mm. The application of a 3D digital-scanned focus field is applied to obtain highly sensitive imaging, and the system operates cooling-free under low gradient conditions. In imaging experiments involving a macaque’s brain, our system demonstrated good quantitative performance. The 3D MPI image yielded satisfactory results for fusion with other structural imaging modalities.


  • Open Access

    Rapid Viscosity Measurement Using Arbitrary Frequency Magnetic Particle Spectrometer

    by Haoran Zhang, Bo Zhang, Xin Feng, Yingqian Zhang, Yundai Chen, Hui Hui, Jie Tian

    Magnetic particle spectrometer (MPS) is the device for characterizing the properties of magnetic nanoparticle (MNP) suspensions, such as viscosity, temperature, and concentration. Specifically, in viscosity measurement, MPS usually works at one or several fixed frequencies. It is challenging to find the appropriate frequency for viscosity measurement of different MNP suspensions. The frequency parameter can be introduced into the measurement method to improve the measurement accuracy. Here, we developed an arbitrary frequency MPS to measure the harmonic amplitudes of the magnetization signals of MNPs, which were generated at various frequencies. A method of measuring the viscosity of MNP suspensions by harmonic ratios at different frequencies was proposed. The viscosity measurement time used in the experiment is 1 s, and the shortest measurement time available is 0.2 s. Experimental results show that the arbitrary frequency MPS can be used to measure viscosities ranging from 0.77 mPa·s to 3.87 mPa·s, and the average measurement deviation is 2.7%. The method was validated using plasma samples from normal rabbits and high-fat diet (HFD) rabbits. Normal rabbit measurements differed from the reference by less than 4.5%, and the plasma viscosity of normal and HFD rabbits could be clearly distinguished.


  • Relaxation spectral analysis in multi‐contrast vascular magnetic particle imaging

    by Xin Feng, Guang Jia, Jiaming Peng, Liyu Huang, Xiaofeng Liang, Haoran Zhang, Yanjun Liu, Bo Zhang, Yifei Zhang, Meng Sun, et al.

    Background: Magnetic nanoparticles (MNPs) are used as tracers without ionizing radiation in vascular imaging, molecular imaging, and neuroimaging. The relaxation mechanisms of magnetization in response to excitation magnetic fields are important features of MNPs. The basic relaxation mechanisms include internal rotation (Néel relaxation) and external physical rotation (Brownian relaxation). Accurate measurement of these relaxation times may provide high sensitivity for predicting MNP types and viscosity‐based hydrodynamic states. It is challenging to separately measure the Néel and Brownian relaxation components using sinusoidal excitation in conventional MPI.Purpose: We developed a multi‐exponential relaxation spectral analysis method to separately measure the Néel and Brownian relaxation times in the magnetization recovery process in pulsed vascular MPI.Methods: Synomag‐D samples with different viscosities were excited using pulsed excitation in a trapezoidal‐waveform relaxometer. The samples were excited at different field amplitudes ranging from 0.5 to 10 mT at intervals of 0.5 mT. The inverse Laplace transform‐based spectral analysis of the relaxation‐induced decay signal in the field‐flat phase was performed by using PDCO, a primal‐dual interior method for convex objectives. Néel and Brownian relaxation peaks were elucidated and measured on samples with various glycerol and gelatin concentrations. The sensitivity of viscosity prediction of the decoupled relaxation times was evaluated. A digital vascular phantom was designed to mimic a plaque with viscous MNPs and a catheter with immobilized MNPs. Spectral imaging of the digital vascular phantom was simulated by combining a field‐free point with homogeneous pulsed excitation. The relationship between the Brownian relaxation time from different tissues and the number of periods for signal averages was evaluated for a scan time estimation in the simulation.Results: The relaxation spectra of synomag‐D samples with different viscosity levels exhibited two relaxation time peaks. The Brownian relaxation time had a positive linear relationship with the viscosity in the range 0.9 to 3.2 mPa · s. When the viscosity was >3.2 mPa · s, the Brownian relaxation time saturated and did not change with increasing viscosity. The Néel relaxation time decreased slightly with an increase in the viscosity. The Néel relaxation time exhibited a similar saturation effect when the viscosity level was >3.2 mPa · s for all field amplitudes. The sensitivity of the Brownian relaxation time increased with the field amplitude and was maximized at approximately 4.5 mT. The plaque and catheter regions were differentiated from the vessel region in the simulated Brownian relaxation time map. The simulation results show that the Néel relaxation time was 8.33±0.09 μs in the plaque region, 8.30±0.08 μs in the catheter region, and 8.46±0.11 μs in the vessel region. The Brownian relaxation time was 36.60±2.31 μs in the plaque region, 30.17±1.24 μs in the catheter region, and 31.21±1.53 μs in the vessel region. If we used 20 excitation periods for image acquisition in the simulation, the total scan time of the digital phantom was approximately 100 s.Conclusion: Quantitative assessment of the Néel and Brownian relaxation times through inverse Laplace transform‐based spectral analysis in pulsed excitation, highlighting their potential for use in multi‐contrast vascular MPI.