Helena Cristina de Assis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Helena Cristina de Assis has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Fabiane Carneiro Lopes-Olhê
Department of Restorative Dentistry, Dental School of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Brazil
15 shared publications - Manoel Damião Sousa-Neto
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
12 shared publications - Jardel Francisco Mazzi-Chaves
University of São Paulo
11 shared publications - Guilherme Nilson Alves dos Santos
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
4 shared publications - Gustavo Creazzo
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
4 shared publications - Antonio Miranda da Cruz-Filho
Department of Restorative Dentistry, School of Dentistry of Ribeirao Preto University of Sao Paulo Ribeirao Preto SP Brazil
3 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 426
Evaluation of the physicochemical properties and adhesive interface quality of BioRoot Flow and BioRoot RCS endodontic sealers: An in vitro study
Objective: Bioceramic sealers have been increasingly used in endodontics due to their favorable physicochemical and biological properties. However, evidence regarding the physicochemical properties, push-out bond strength, and adhesive interface characteristics of BioRoot Flow compared with other root canal sealers remains limited. Therefore, this study evaluated the physicochemical properties, push-out bond strength, failure pattern, and adhesive interface quality of BioRoot Flow (BRF), BioRoot RCS (BRR), and the epoxy resin–based sealer AH Plus (AHP). Methods: Setting time, dimensional change, solubility, radiopacity, and flow were assessed following ANSI/ADA Specification No. 57. Setting time was recorded using cylindrical molds tested with a Gillmore needle. Dimensional change was measured in five specimens per sealer before and after 30 days in distilled water. Solubility was assessed in ten specimens after seven days of immersion, followed by desiccation. Radiopacity was evaluated using acrylic plates radiographed beside an aluminum step wedge. Flow was assessed according to ANSI/ADA standards. For bond strength and interface analysis, thirty single-rooted teeth were prepared with the Reciproc system and irrigated with sodium hypochlorite and EDTA. Canals were obturated with the single-cone technique using the tested sealers ( n = 10). Three slices were obtained from each root third; two were used for push-out testing and failure analysis, and one for confocal laser scanning microscopy. Results: AHP showed the shortest setting time, highest radiopacity, and greatest flow. BRF exhibited the highest solubility, while dimensional change did not differ among materials. Bond strength varied significantly among sealers and root thirds; AHP presented the highest values, followed by BRF and BRR. Adhesive failures predominated for AHP, whereas bioceramic sealers showed mainly mixed failures. Conclusion: AHP demonstrated superior physicochemical properties, higher bond strength, and better adhesive interface adaptation. BRF performed better than BRR regarding bonding and interface quality.
- 2 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 426
Open AccessEvaluation of the physicochemical properties and adhesive interface quality of BioRoot Flow and BioRoot RCS endodontic sealers: An in vitro study
Objective: Bioceramic sealers have been increasingly used in endodontics due to their favorable physicochemical and biological properties. However, evidence regarding the physicochemical properties, push-out bond strength, and adhesive interface characteristics of BioRoot Flow compared with other root canal sealers remains limited. Therefore, this study evaluated the physicochemical properties, push-out bond strength, failure pattern, and adhesive interface quality of BioRoot Flow (BRF), BioRoot RCS (BRR), and the epoxy resin–based sealer AH Plus (AHP). Methods: Setting time, dimensional change, solubility, radiopacity, and flow were assessed following ANSI/ADA Specification No. 57. Setting time was recorded using cylindrical molds tested with a Gillmore needle. Dimensional change was measured in five specimens per sealer before and after 30 days in distilled water. Solubility was assessed in ten specimens after seven days of immersion, followed by desiccation. Radiopacity was evaluated using acrylic plates radiographed beside an aluminum step wedge. Flow was assessed according to ANSI/ADA standards. For bond strength and interface analysis, thirty single-rooted teeth were prepared with the Reciproc system and irrigated with sodium hypochlorite and EDTA. Canals were obturated with the single-cone technique using the tested sealers ( n = 10). Three slices were obtained from each root third; two were used for push-out testing and failure analysis, and one for confocal laser scanning microscopy. Results: AHP showed the shortest setting time, highest radiopacity, and greatest flow. BRF exhibited the highest solubility, while dimensional change did not differ among materials. Bond strength varied significantly among sealers and root thirds; AHP presented the highest values, followed by BRF and BRR. Adhesive failures predominated for AHP, whereas bioceramic sealers showed mainly mixed failures. Conclusion: AHP demonstrated superior physicochemical properties, higher bond strength, and better adhesive interface adaptation. BRF performed better than BRR regarding bonding and interface quality.
- Open Access
- 17 June 2026
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 60, 105545
Apical debris extrusion following photon-induced photoacoustic streaming, high-power laser, and other irrigation techniques: A systematic review
- 17 June 2026
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 60, 105545
Open AccessApical debris extrusion following photon-induced photoacoustic streaming, high-power laser, and other irrigation techniques: A systematic review
- 16 January 2026
- Published by Wiley in Australian Endodontic Journal
- Vol. 52 (1) , 227-235
Effect of Glycolic Acid on the Bond Strength Longevity of Bioceramic and Resin Based Endodontic Sealers: An In Vitro Study
This study evaluated the effect of glycolic acid (GA) as a final irrigant on the long‐term bond strength of AH Plus and Bio‐C Sealer. Forty‐eight single‐rooted teeth were assigned to four groups ( n = 12): ethylenediaminetetraacetic acid (EDTA) + AH Plus, glycolic acid + AH Plus, EDTA + Bio‐C Sealer, and glycolic acid + Bio‐C Sealer. The bond strength and failure pattern were evaluated immediately and after 6 months, while the interface adaptation and sealer penetrability were also assessed. Immediate bond strength did not differ between groups, but after 6 months AH Plus showed higher values than Bio‐C Sealer. The failure pattern was similar among all groups at both evaluation time points. EDTA + AH Plus exhibited superior interface adaptation compared with EDTA + Bio‐C Sealer, particularly in the cervical third. Sealer penetrability was comparable among groups. Glycolic acid produced similar outcomes to EDTA, and AH Plus maintained greater bond strength over time.
- 16 January 2026
- Published by Wiley in Australian Endodontic Journal
- Vol. 52 (1) , 227-235
Effect of Glycolic Acid on the Bond Strength Longevity of Bioceramic and Resin Based Endodontic Sealers: An In Vitro Study
This study evaluated the effect of glycolic acid (GA) as a final irrigant on the long‐term bond strength of AH Plus and Bio‐C Sealer. Forty‐eight single‐rooted teeth were assigned to four groups ( n = 12): ethylenediaminetetraacetic acid (EDTA) + AH Plus, glycolic acid + AH Plus, EDTA + Bio‐C Sealer, and glycolic acid + Bio‐C Sealer. The bond strength and failure pattern were evaluated immediately and after 6 months, while the interface adaptation and sealer penetrability were also assessed. Immediate bond strength did not differ between groups, but after 6 months AH Plus showed higher values than Bio‐C Sealer. The failure pattern was similar among all groups at both evaluation time points. EDTA + AH Plus exhibited superior interface adaptation compared with EDTA + Bio‐C Sealer, particularly in the cervical third. Sealer penetrability was comparable among groups. Glycolic acid produced similar outcomes to EDTA, and AH Plus maintained greater bond strength over time.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
Effectiveness of cleaning protocols for temporary methacrylate-based resin cements in root canal dentin
Residual temporary cement may hinder fiber post bonding. Therefore, efficient root canal cleaning protocols are essential. This study investigated the effects of three cleaning methods on bond strength, adhesive interface quality as evaluated using scanning electron microscopy (SEM), and intratubular penetration of a self-adhesive resin cement as evaluated using confocal laser scanning microscopy (CLSM). Forty-two mandibular premolars were prepared using Reciproc R50, filled with AH Plus, and restored with provisional retainers cemented with Bifix Temp. Specimens were allocated to three groups (n = 14) according to the cleaning protocol: standardized drill (SD), drill with an ultrasonic insert (UI), or drill with a prophylactic brush (PB). Fiber posts were cemented using a self-adhesive resin cement. Push-out testing, failure mode analysis, and SEM/CLSM evaluations were performed. Bond strength (MPa) was analyzed using two-way ANOVA followed by Tukey's test, whereas failure patterns were analyzed using the chi-square test, and interface adaptation was analyzed using nonparametric tests. PB (4.42 ± 2.60 MPa) and UI (4.55 ± 2.41 MPa) showed significantly higher bond strength values and greater cement penetration than SD (3.04 ± 1.70 MPa) (p < 0.05). Mixed adhesive failures predominated, and SEM revealed no significant differences in interface adaptation. Cleaning with a PB or UI enhanced adhesive performance and resin cement penetration during fiberglass post cementation.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 40
Open AccessEffectiveness of cleaning protocols for temporary methacrylate-based resin cements in root canal dentin
Residual temporary cement may hinder fiber post bonding. Therefore, efficient root canal cleaning protocols are essential. This study investigated the effects of three cleaning methods on bond strength, adhesive interface quality as evaluated using scanning electron microscopy (SEM), and intratubular penetration of a self-adhesive resin cement as evaluated using confocal laser scanning microscopy (CLSM). Forty-two mandibular premolars were prepared using Reciproc R50, filled with AH Plus, and restored with provisional retainers cemented with Bifix Temp. Specimens were allocated to three groups (n = 14) according to the cleaning protocol: standardized drill (SD), drill with an ultrasonic insert (UI), or drill with a prophylactic brush (PB). Fiber posts were cemented using a self-adhesive resin cement. Push-out testing, failure mode analysis, and SEM/CLSM evaluations were performed. Bond strength (MPa) was analyzed using two-way ANOVA followed by Tukey's test, whereas failure patterns were analyzed using the chi-square test, and interface adaptation was analyzed using nonparametric tests. PB (4.42 ± 2.60 MPa) and UI (4.55 ± 2.41 MPa) showed significantly higher bond strength values and greater cement penetration than SD (3.04 ± 1.70 MPa) (p < 0.05). Mixed adhesive failures predominated, and SEM revealed no significant differences in interface adaptation. Cleaning with a PB or UI enhanced adhesive performance and resin cement penetration during fiberglass post cementation.
- 15 October 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 1-13
Effect of Nd: YAG laser on the treatment of intraradicular dentin prior obturation with calcium silicate-based sealer
To evaluate the effect of Nd:YAG laser irradiation on intraradicular dentin prior to obturation with calcium silicate-based and epoxy resin-based sealers, focusing on push-out bond strength, failure pattern using a stereomicroscope, adhesive interface quality via confocal laser scanning microscopy (CLSM), chemical composition using Raman spectroscopy, and dentin surface morphological alterations through scanning electron microscopy (SEM). Forty-six teeth were sectioned to standardize root length (16 mm) and prepared using a reciprocating R50 instrument. Specimens were randomly divided into control (no treatment) and Nd: YAG laser (1,064 nm) groups, with laser irradiation performed at 1.5 W, 25 Hz, for 20 s using a 400 μm fiber in a helical motion (1.5 mm/s). Twenty specimens per group were obturated using the single-cone technique with R50 gutta-percha and further subdivided by sealer: AH Plus (n = 10) and Bio-C Sealer (n = 10), with and without laser treatment. Three non-obturated specimens per group underwent Raman spectroscopy and SEM analysis of intracanal dentin. After 30 days at 37 °C, obturated samples were sectioned into slices (nine per specimen). The first two slices per third underwent push-out bond strength testing and failure analysis, while the third was examined via CLSM for adhesive interface quality. Bond strength was analyzed using three-way ANOVA, chemical composition by two-way ANOVA, failure patterns by chi-square, and interface adaptation by Kruskal-Wallis with post-hoc tests (p < 0.05). In laser groups, Bio-C Sealer showed higher bond strength in the cervical third (p = 0.011), whereas AH Plus maintained superior values in the middle and apical thirds (p < 0.001). The laser group obturated with Bio-C Sealer demonstrated adhesive interface adaptation comparable to the control group obturated with AH Plus (p = 1.000) and superior to the control group obturated with Bio-C Sealer (p = 0.037). Laser groups exhibited more mixed failures, while control groups showed a higher prevalence of adhesive failures (p = 0.045). Laser irradiation resulted in lower organic content intensity in the cervical third (p = 0.002) and an increased inorganic/organic ratio (p < 0.001). Additionally, it induced fusion and obliteration of dentinal tubules in the cervical third, whereas alternating areas of fused dentin and exposed tubules were observed in the middle and apical thirds. The Nd:YAG laser treatment of intraradicular dentin prior obturation positively influenced the obturation process when associated with Bio-C Sealer, particularly in the cervical third. Therefore, Nd:YAG laser may be a promising approach to enhance bond strength and improve the adhesive interface quality of obturations performed with calcium silicate-based sealers.
- 15 October 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 1-13
Effect of Nd: YAG laser on the treatment of intraradicular dentin prior obturation with calcium silicate-based sealer
To evaluate the effect of Nd:YAG laser irradiation on intraradicular dentin prior to obturation with calcium silicate-based and epoxy resin-based sealers, focusing on push-out bond strength, failure pattern using a stereomicroscope, adhesive interface quality via confocal laser scanning microscopy (CLSM), chemical composition using Raman spectroscopy, and dentin surface morphological alterations through scanning electron microscopy (SEM). Forty-six teeth were sectioned to standardize root length (16 mm) and prepared using a reciprocating R50 instrument. Specimens were randomly divided into control (no treatment) and Nd: YAG laser (1,064 nm) groups, with laser irradiation performed at 1.5 W, 25 Hz, for 20 s using a 400 μm fiber in a helical motion (1.5 mm/s). Twenty specimens per group were obturated using the single-cone technique with R50 gutta-percha and further subdivided by sealer: AH Plus (n = 10) and Bio-C Sealer (n = 10), with and without laser treatment. Three non-obturated specimens per group underwent Raman spectroscopy and SEM analysis of intracanal dentin. After 30 days at 37 °C, obturated samples were sectioned into slices (nine per specimen). The first two slices per third underwent push-out bond strength testing and failure analysis, while the third was examined via CLSM for adhesive interface quality. Bond strength was analyzed using three-way ANOVA, chemical composition by two-way ANOVA, failure patterns by chi-square, and interface adaptation by Kruskal-Wallis with post-hoc tests (p < 0.05). In laser groups, Bio-C Sealer showed higher bond strength in the cervical third (p = 0.011), whereas AH Plus maintained superior values in the middle and apical thirds (p < 0.001). The laser group obturated with Bio-C Sealer demonstrated adhesive interface adaptation comparable to the control group obturated with AH Plus (p = 1.000) and superior to the control group obturated with Bio-C Sealer (p = 0.037). Laser groups exhibited more mixed failures, while control groups showed a higher prevalence of adhesive failures (p = 0.045). Laser irradiation resulted in lower organic content intensity in the cervical third (p = 0.002) and an increased inorganic/organic ratio (p < 0.001). Additionally, it induced fusion and obliteration of dentinal tubules in the cervical third, whereas alternating areas of fused dentin and exposed tubules were observed in the middle and apical thirds. The Nd:YAG laser treatment of intraradicular dentin prior obturation positively influenced the obturation process when associated with Bio-C Sealer, particularly in the cervical third. Therefore, Nd:YAG laser may be a promising approach to enhance bond strength and improve the adhesive interface quality of obturations performed with calcium silicate-based sealers.
- 7 August 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (12) , 1783-1792
Biomechanical Behavior of Maxillary Premolars with Non-carious Cervical Lesions: Influence of Minimally Invasive Endodontic Access and Restoration Protocols
- 7 August 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (12) , 1783-1792
Biomechanical Behavior of Maxillary Premolars with Non-carious Cervical Lesions: Influence of Minimally Invasive Endodontic Access and Restoration Protocols
- 5 July 2025
- Published by Springer Nature in Odontology
- Vol. 114 (2) , 642-651
Effect of radiotherapy on the biomechanical preparation of different instrumentation kinematics
To evaluate the effect of biomechanical preparation on irradiated root dentin after the use of different endodontic instrumentation techniques. Sixty mandibular canines were randomly assigned to two groups: non-irradiated (30 canines) and irradiated (30 canines subjected to 30 cycles of 2 Gy, totaling 60 Gy). After radiotherapy, the samples were scanned using micro-CT to assess the 3D morphology of the root canal and to calculate the length, thickness, volume, surface area and transport of the canal. The groups were redistributed into 3 subgroups (n = 10) according to the instrumentation protocol: GI—manual M-easy Ni–Ti file up to #50.05; GII—rotary instrument ProTaper Next up to #50/.06; GIII—reciprocating instrument Reciproc #R50. After instrumentation, the specimens were scanned again in micro-CT following the same parameters as the initial acquisition. Statistical analysis was performed using two-factor analysis of variance (ANOVA) test with Tukey’s post-test considering the variables “instrumentation protocol” and “radiotherapy”. The three-factor ANOVA test with Tukey’s post-test was carried out to compare the influence of radiotherapy, instrumentation and root thirds (cervical, middle and apical) on root canal transportation data. Irradiated teeth showed a greater increase in surface area and percentage of walls touched, while for root canal transport and volume, differences were observed only in relation to the type of preparation, in ascending order for the manual, rotary and reciprocating systems. Descriptive analysis showed that altered thickness in the middle-apical thirds occurred mainly in teeth irradiated with rotary and reciprocating instrumentation protocols. Irradiation of teeth can affect biomechanical preparation parameters of different instrument kinematics used to prepare canine root canals.
- 5 July 2025
- Published by Springer Nature in Odontology
- Vol. 114 (2) , 642-651
Effect of radiotherapy on the biomechanical preparation of different instrumentation kinematics
To evaluate the effect of biomechanical preparation on irradiated root dentin after the use of different endodontic instrumentation techniques. Sixty mandibular canines were randomly assigned to two groups: non-irradiated (30 canines) and irradiated (30 canines subjected to 30 cycles of 2 Gy, totaling 60 Gy). After radiotherapy, the samples were scanned using micro-CT to assess the 3D morphology of the root canal and to calculate the length, thickness, volume, surface area and transport of the canal. The groups were redistributed into 3 subgroups (n = 10) according to the instrumentation protocol: GI—manual M-easy Ni–Ti file up to #50.05; GII—rotary instrument ProTaper Next up to #50/.06; GIII—reciprocating instrument Reciproc #R50. After instrumentation, the specimens were scanned again in micro-CT following the same parameters as the initial acquisition. Statistical analysis was performed using two-factor analysis of variance (ANOVA) test with Tukey’s post-test considering the variables “instrumentation protocol” and “radiotherapy”. The three-factor ANOVA test with Tukey’s post-test was carried out to compare the influence of radiotherapy, instrumentation and root thirds (cervical, middle and apical) on root canal transportation data. Irradiated teeth showed a greater increase in surface area and percentage of walls touched, while for root canal transport and volume, differences were observed only in relation to the type of preparation, in ascending order for the manual, rotary and reciprocating systems. Descriptive analysis showed that altered thickness in the middle-apical thirds occurred mainly in teeth irradiated with rotary and reciprocating instrumentation protocols. Irradiation of teeth can affect biomechanical preparation parameters of different instrument kinematics used to prepare canine root canals.
- 1 March 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (7) , 1989-2000
Bond Strength and Adhesive Interface Quality of New Pre‐Mixed Bioceramic Root Canal Sealer
To evaluate the bond strength and adhesive interface quality between root dentin and pre‐mixed bioceramic sealers: AH Plus Bioceramic, Bio‐C Sealer, and NeoSEALER Flo. Thirty‐six single‐rooted teeth were endodontically treated and divided into three groups (n = 12) based on the sealer used: GI‐AH Plus Bioceramic; GII‐Bio‐C Sealer; GIII‐NeoSEALER Flo. Fluorescein dye was added to two samples of each group. After three times the sealer's setting time, specimens were sectioned. The first and second slices underwent push‐out testing with failure pattern analysis (n = 10). The third slice was used for confocal laser scanning microscopy (CLSM) (n = 10). Samples with dye were analyzed using confocal laser scanning fluorescence microscopy (CLSM). Data were analyzed using ANOVA, χ2, and Kruskal–Wallis tests. The two‐way ANOVA t revealed significant differences for the sealer factor, with Bio‐C Sealer showing the highest bond strength (2.61 ± 1.58), followed by NeoSEALER Flo (1.76 ± 1.30) and AH Plus Bioceramic (1.37 ± 1.44). NeoSEALER Flo showed values similar to AH Plus Bioceramic and Bio‐C Sealer. The χ2 test revealed a significant difference in failure type across root thirds, with adhesive and cohesive failures more common in the apical third. No significant differences were found between sealers or root thirds for penetrability. Bio‐C Sealer exhibited the highest bond strength, while NeoSEALER Flo showed intermediate results. Both Bio‐C Sealer and NeoSEALER Flo demonstrated superior adhesive interface adaptation, with no significant differences in penetrability among sealers.
- 1 March 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (7) , 1989-2000
Bond Strength and Adhesive Interface Quality of New Pre‐Mixed Bioceramic Root Canal Sealer
To evaluate the bond strength and adhesive interface quality between root dentin and pre‐mixed bioceramic sealers: AH Plus Bioceramic, Bio‐C Sealer, and NeoSEALER Flo. Thirty‐six single‐rooted teeth were endodontically treated and divided into three groups (n = 12) based on the sealer used: GI‐AH Plus Bioceramic; GII‐Bio‐C Sealer; GIII‐NeoSEALER Flo. Fluorescein dye was added to two samples of each group. After three times the sealer's setting time, specimens were sectioned. The first and second slices underwent push‐out testing with failure pattern analysis (n = 10). The third slice was used for confocal laser scanning microscopy (CLSM) (n = 10). Samples with dye were analyzed using confocal laser scanning fluorescence microscopy (CLSM). Data were analyzed using ANOVA, χ2, and Kruskal–Wallis tests. The two‐way ANOVA t revealed significant differences for the sealer factor, with Bio‐C Sealer showing the highest bond strength (2.61 ± 1.58), followed by NeoSEALER Flo (1.76 ± 1.30) and AH Plus Bioceramic (1.37 ± 1.44). NeoSEALER Flo showed values similar to AH Plus Bioceramic and Bio‐C Sealer. The χ2 test revealed a significant difference in failure type across root thirds, with adhesive and cohesive failures more common in the apical third. No significant differences were found between sealers or root thirds for penetrability. Bio‐C Sealer exhibited the highest bond strength, while NeoSEALER Flo showed intermediate results. Both Bio‐C Sealer and NeoSEALER Flo demonstrated superior adhesive interface adaptation, with no significant differences in penetrability among sealers.