Gustavo Creazzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gustavo Creazzo has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Fabiane Carneiro Lopes-Olhê
Department of Restorative Dentistry, Dental School of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Brazil
5 shared publications - Jardel Francisco Mazzi-Chaves
University of São Paulo
5 shared publications - Manoel Damião Sousa-Neto
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
5 shared publications - Helena Cristina de Assis
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
4 shared publications - Gabrielle Jacob
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto University of São Paulo (USP) Ribeirão Preto São Paulo Brazil
3 shared publications - Bruna Monteiro de Barros Ciribelli Alves
Department of Restorative Dentistry School of Dentistry of Ribeirão Preto, University of São Paulo (USP) Ribeirão Preto São Paulo Brazil
2 shared publications
Latest Publications
- Open Access
- 27 September 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 153
Impact of drying protocols on bond strength and adhesive interface quality of premixed and powder/liquid bioceramic root canal sealers
- 27 September 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 153
Open AccessImpact of drying protocols on bond strength and adhesive interface quality of premixed and powder/liquid bioceramic root canal sealers
- Open Access
- 2 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 426
Evaluation of the physicochemical properties and adhesive interface quality of BioRoot Flow and BioRoot RCS endodontic sealers: An in vitro study
Objective: Bioceramic sealers have been increasingly used in endodontics due to their favorable physicochemical and biological properties. However, evidence regarding the physicochemical properties, push-out bond strength, and adhesive interface characteristics of BioRoot Flow compared with other root canal sealers remains limited. Therefore, this study evaluated the physicochemical properties, push-out bond strength, failure pattern, and adhesive interface quality of BioRoot Flow (BRF), BioRoot RCS (BRR), and the epoxy resin–based sealer AH Plus (AHP). Methods: Setting time, dimensional change, solubility, radiopacity, and flow were assessed following ANSI/ADA Specification No. 57. Setting time was recorded using cylindrical molds tested with a Gillmore needle. Dimensional change was measured in five specimens per sealer before and after 30 days in distilled water. Solubility was assessed in ten specimens after seven days of immersion, followed by desiccation. Radiopacity was evaluated using acrylic plates radiographed beside an aluminum step wedge. Flow was assessed according to ANSI/ADA standards. For bond strength and interface analysis, thirty single-rooted teeth were prepared with the Reciproc system and irrigated with sodium hypochlorite and EDTA. Canals were obturated with the single-cone technique using the tested sealers ( n = 10). Three slices were obtained from each root third; two were used for push-out testing and failure analysis, and one for confocal laser scanning microscopy. Results: AHP showed the shortest setting time, highest radiopacity, and greatest flow. BRF exhibited the highest solubility, while dimensional change did not differ among materials. Bond strength varied significantly among sealers and root thirds; AHP presented the highest values, followed by BRF and BRR. Adhesive failures predominated for AHP, whereas bioceramic sealers showed mainly mixed failures. Conclusion: AHP demonstrated superior physicochemical properties, higher bond strength, and better adhesive interface adaptation. BRF performed better than BRR regarding bonding and interface quality.
- 2 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 426
Open AccessEvaluation of the physicochemical properties and adhesive interface quality of BioRoot Flow and BioRoot RCS endodontic sealers: An in vitro study
Objective: Bioceramic sealers have been increasingly used in endodontics due to their favorable physicochemical and biological properties. However, evidence regarding the physicochemical properties, push-out bond strength, and adhesive interface characteristics of BioRoot Flow compared with other root canal sealers remains limited. Therefore, this study evaluated the physicochemical properties, push-out bond strength, failure pattern, and adhesive interface quality of BioRoot Flow (BRF), BioRoot RCS (BRR), and the epoxy resin–based sealer AH Plus (AHP). Methods: Setting time, dimensional change, solubility, radiopacity, and flow were assessed following ANSI/ADA Specification No. 57. Setting time was recorded using cylindrical molds tested with a Gillmore needle. Dimensional change was measured in five specimens per sealer before and after 30 days in distilled water. Solubility was assessed in ten specimens after seven days of immersion, followed by desiccation. Radiopacity was evaluated using acrylic plates radiographed beside an aluminum step wedge. Flow was assessed according to ANSI/ADA standards. For bond strength and interface analysis, thirty single-rooted teeth were prepared with the Reciproc system and irrigated with sodium hypochlorite and EDTA. Canals were obturated with the single-cone technique using the tested sealers ( n = 10). Three slices were obtained from each root third; two were used for push-out testing and failure analysis, and one for confocal laser scanning microscopy. Results: AHP showed the shortest setting time, highest radiopacity, and greatest flow. BRF exhibited the highest solubility, while dimensional change did not differ among materials. Bond strength varied significantly among sealers and root thirds; AHP presented the highest values, followed by BRF and BRR. Adhesive failures predominated for AHP, whereas bioceramic sealers showed mainly mixed failures. Conclusion: AHP demonstrated superior physicochemical properties, higher bond strength, and better adhesive interface adaptation. BRF performed better than BRR regarding bonding and interface quality.
- 16 January 2026
- Published by Wiley in Australian Endodontic Journal
- Vol. 52 (1) , 227-235
Effect of Glycolic Acid on the Bond Strength Longevity of Bioceramic and Resin Based Endodontic Sealers: An In Vitro Study
This study evaluated the effect of glycolic acid (GA) as a final irrigant on the long‐term bond strength of AH Plus and Bio‐C Sealer. Forty‐eight single‐rooted teeth were assigned to four groups ( n = 12): ethylenediaminetetraacetic acid (EDTA) + AH Plus, glycolic acid + AH Plus, EDTA + Bio‐C Sealer, and glycolic acid + Bio‐C Sealer. The bond strength and failure pattern were evaluated immediately and after 6 months, while the interface adaptation and sealer penetrability were also assessed. Immediate bond strength did not differ between groups, but after 6 months AH Plus showed higher values than Bio‐C Sealer. The failure pattern was similar among all groups at both evaluation time points. EDTA + AH Plus exhibited superior interface adaptation compared with EDTA + Bio‐C Sealer, particularly in the cervical third. Sealer penetrability was comparable among groups. Glycolic acid produced similar outcomes to EDTA, and AH Plus maintained greater bond strength over time.
- 16 January 2026
- Published by Wiley in Australian Endodontic Journal
- Vol. 52 (1) , 227-235
Effect of Glycolic Acid on the Bond Strength Longevity of Bioceramic and Resin Based Endodontic Sealers: An In Vitro Study
This study evaluated the effect of glycolic acid (GA) as a final irrigant on the long‐term bond strength of AH Plus and Bio‐C Sealer. Forty‐eight single‐rooted teeth were assigned to four groups ( n = 12): ethylenediaminetetraacetic acid (EDTA) + AH Plus, glycolic acid + AH Plus, EDTA + Bio‐C Sealer, and glycolic acid + Bio‐C Sealer. The bond strength and failure pattern were evaluated immediately and after 6 months, while the interface adaptation and sealer penetrability were also assessed. Immediate bond strength did not differ between groups, but after 6 months AH Plus showed higher values than Bio‐C Sealer. The failure pattern was similar among all groups at both evaluation time points. EDTA + AH Plus exhibited superior interface adaptation compared with EDTA + Bio‐C Sealer, particularly in the cervical third. Sealer penetrability was comparable among groups. Glycolic acid produced similar outcomes to EDTA, and AH Plus maintained greater bond strength over time.
- 7 August 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (12) , 1783-1792
Biomechanical Behavior of Maxillary Premolars with Non-carious Cervical Lesions: Influence of Minimally Invasive Endodontic Access and Restoration Protocols
- 7 August 2025
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (12) , 1783-1792
Biomechanical Behavior of Maxillary Premolars with Non-carious Cervical Lesions: Influence of Minimally Invasive Endodontic Access and Restoration Protocols
- 1 March 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (7) , 1989-2000
Bond Strength and Adhesive Interface Quality of New Pre‐Mixed Bioceramic Root Canal Sealer
To evaluate the bond strength and adhesive interface quality between root dentin and pre‐mixed bioceramic sealers: AH Plus Bioceramic, Bio‐C Sealer, and NeoSEALER Flo. Thirty‐six single‐rooted teeth were endodontically treated and divided into three groups (n = 12) based on the sealer used: GI‐AH Plus Bioceramic; GII‐Bio‐C Sealer; GIII‐NeoSEALER Flo. Fluorescein dye was added to two samples of each group. After three times the sealer's setting time, specimens were sectioned. The first and second slices underwent push‐out testing with failure pattern analysis (n = 10). The third slice was used for confocal laser scanning microscopy (CLSM) (n = 10). Samples with dye were analyzed using confocal laser scanning fluorescence microscopy (CLSM). Data were analyzed using ANOVA, χ2, and Kruskal–Wallis tests. The two‐way ANOVA t revealed significant differences for the sealer factor, with Bio‐C Sealer showing the highest bond strength (2.61 ± 1.58), followed by NeoSEALER Flo (1.76 ± 1.30) and AH Plus Bioceramic (1.37 ± 1.44). NeoSEALER Flo showed values similar to AH Plus Bioceramic and Bio‐C Sealer. The χ2 test revealed a significant difference in failure type across root thirds, with adhesive and cohesive failures more common in the apical third. No significant differences were found between sealers or root thirds for penetrability. Bio‐C Sealer exhibited the highest bond strength, while NeoSEALER Flo showed intermediate results. Both Bio‐C Sealer and NeoSEALER Flo demonstrated superior adhesive interface adaptation, with no significant differences in penetrability among sealers.
- 1 March 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 88 (7) , 1989-2000
Bond Strength and Adhesive Interface Quality of New Pre‐Mixed Bioceramic Root Canal Sealer
To evaluate the bond strength and adhesive interface quality between root dentin and pre‐mixed bioceramic sealers: AH Plus Bioceramic, Bio‐C Sealer, and NeoSEALER Flo. Thirty‐six single‐rooted teeth were endodontically treated and divided into three groups (n = 12) based on the sealer used: GI‐AH Plus Bioceramic; GII‐Bio‐C Sealer; GIII‐NeoSEALER Flo. Fluorescein dye was added to two samples of each group. After three times the sealer's setting time, specimens were sectioned. The first and second slices underwent push‐out testing with failure pattern analysis (n = 10). The third slice was used for confocal laser scanning microscopy (CLSM) (n = 10). Samples with dye were analyzed using confocal laser scanning fluorescence microscopy (CLSM). Data were analyzed using ANOVA, χ2, and Kruskal–Wallis tests. The two‐way ANOVA t revealed significant differences for the sealer factor, with Bio‐C Sealer showing the highest bond strength (2.61 ± 1.58), followed by NeoSEALER Flo (1.76 ± 1.30) and AH Plus Bioceramic (1.37 ± 1.44). NeoSEALER Flo showed values similar to AH Plus Bioceramic and Bio‐C Sealer. The χ2 test revealed a significant difference in failure type across root thirds, with adhesive and cohesive failures more common in the apical third. No significant differences were found between sealers or root thirds for penetrability. Bio‐C Sealer exhibited the highest bond strength, while NeoSEALER Flo showed intermediate results. Both Bio‐C Sealer and NeoSEALER Flo demonstrated superior adhesive interface adaptation, with no significant differences in penetrability among sealers.