Hossein Rajabi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hossein Rajabi has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Samira Rasaneh
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-331, Tehran, Iran
3 shared publications - Ahmad Bitarafan-Rajabi
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
2 shared publications Asra Sadat Talebi
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
2 shared publicationsFaraz Kalantari
Department of Radiation Oncology University of Arkansas for Medical Sciences Little Rock Arkansas USA
2 shared publicationsMohammad Hossein Babaei
Nuclear Science and Technology Research Institute
2 shared publicationsA. A. Parach
Dept. of Medical Physics, Faculty of Medical Sciences, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 12 January 2026
- Published by BON VIEW PUBLISHING PTE in Journal of Optics and Photonics Research
- Vol. 3 (3) , 233-240
Comparative Analysis of Corneal and Lens Doses in Nuclear Medicine and Impact of Lead Eyeglasses: A Monte Carlo Simulation Approach
Research on eye lens dosimetry for radiation workers has increased after the 2012 International Commission on Radiological Protection 118 update on eye lens dose limits, while corneal dosimetry has remained underexplored due to historical focus and measurement challenges. This study employed a high-resolution digital eye phantom in Monte Carlo simulations to estimate corneal and lens doses for nuclear medicine staff, with and without lead glasses. Using the Monte Carlo code GATE (Geant4 Application for Tomographic Emission) (version 9.0), based on the GEANT4 toolkit (version 10.6), we estimated doses from primary and scattered radiation emitted by common radionuclides (18F, 131I, 99mTc) under varying lead glass shielding thicknesses (0–0.75 mm). The simulations demonstrated that across all radionuclides, the dose to the cornea was consistently higher than the dose to the lens. Moreover, the ratio of corneal to lens dose increased with thicker lead glasses, reflecting a greater relative dose reduction to the lens. These findings indicate that while thicker lead glasses enhance lens protection, they reduce corneal exposure less effectively, thereby raising the cornea-to-lens dose ratio. Although protective eyewear remains important, its practicality may be limited by diminishing returns in shielding effectiveness and potential discomfort. Overall, this work highlights the necessity of considering both corneal and lens dosimetry to optimize occupational eye protection strategies in nuclear medicine. Received: 29 March 2025 | Revised: 8 September 2025 | Accepted: 17 December 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data sharing is not applicable to this article as no new data were created or analyzed in this study. Author Contribution Statement Zahra Akbari Khanaposhtani: Conceptualization, Methodology, Software, Formal analysis, Investigation, Data curation, Writing – original draft, Visualization. Hossein Rajabi: Conceptualization, Methodology, Validation, Resources, Writing – review & editing, Supervision, Project administration.
- 12 January 2026
- Published by BON VIEW PUBLISHING PTE in Journal of Optics and Photonics Research
- Vol. 3 (3) , 233-240
Open AccessComparative Analysis of Corneal and Lens Doses in Nuclear Medicine and Impact of Lead Eyeglasses: A Monte Carlo Simulation Approach
Research on eye lens dosimetry for radiation workers has increased after the 2012 International Commission on Radiological Protection 118 update on eye lens dose limits, while corneal dosimetry has remained underexplored due to historical focus and measurement challenges. This study employed a high-resolution digital eye phantom in Monte Carlo simulations to estimate corneal and lens doses for nuclear medicine staff, with and without lead glasses. Using the Monte Carlo code GATE (Geant4 Application for Tomographic Emission) (version 9.0), based on the GEANT4 toolkit (version 10.6), we estimated doses from primary and scattered radiation emitted by common radionuclides (18F, 131I, 99mTc) under varying lead glass shielding thicknesses (0–0.75 mm). The simulations demonstrated that across all radionuclides, the dose to the cornea was consistently higher than the dose to the lens. Moreover, the ratio of corneal to lens dose increased with thicker lead glasses, reflecting a greater relative dose reduction to the lens. These findings indicate that while thicker lead glasses enhance lens protection, they reduce corneal exposure less effectively, thereby raising the cornea-to-lens dose ratio. Although protective eyewear remains important, its practicality may be limited by diminishing returns in shielding effectiveness and potential discomfort. Overall, this work highlights the necessity of considering both corneal and lens dosimetry to optimize occupational eye protection strategies in nuclear medicine. Received: 29 March 2025 | Revised: 8 September 2025 | Accepted: 17 December 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data sharing is not applicable to this article as no new data were created or analyzed in this study. Author Contribution Statement Zahra Akbari Khanaposhtani: Conceptualization, Methodology, Software, Formal analysis, Investigation, Data curation, Writing – original draft, Visualization. Hossein Rajabi: Conceptualization, Methodology, Validation, Resources, Writing – review & editing, Supervision, Project administration.
- Open Access
- 1 October 2025
- Published by InkVista Publishing House in International Journal of Radiation Research
- Vol. 23 (4) , 1029-1036
Dosimetric assessment of photon, proton, and carbon ion beams in a magnetic field; a Monte Carlo simulation study
Background: The advent of Magnetic Resonance-guided (MR-guided) radiotherapy, facilitated by MR-guided linear accelerators (MR-LINACs), has significantly enhanced the availability of online adaptive radiotherapy treatments. Research indicates that a static magnetic field influences the amount of radiation absorbed by patients undergoing MR-guided radiotherapy. This study employed Monte Carlo simulations to assess the ...
- 1 October 2025
- Published by InkVista Publishing House in International Journal of Radiation Research
- Vol. 23 (4) , 1029-1036
Open AccessDosimetric assessment of photon, proton, and carbon ion beams in a magnetic field; a Monte Carlo simulation study
Background: The advent of Magnetic Resonance-guided (MR-guided) radiotherapy, facilitated by MR-guided linear accelerators (MR-LINACs), has significantly enhanced the availability of online adaptive radiotherapy treatments. Research indicates that a static magnetic field influences the amount of radiation absorbed by patients undergoing MR-guided radiotherapy. This study employed Monte Carlo simulations to assess the ...
- 11 December 2024
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 64 (02) , 132-140
The impact of the xSPECT reconstruction algorithms on the recovery coefficients value for small tumors: a phantom study with 177Lu
Quantifying small tumors is still a challenge due to the partial volume effect (PVE). Although iterative reconstruction had promising results with a better recovery coefficient (RC), it suffers from the PVE. RC values typically depend on the reconstruction method, which may affect on 177Lu quantifying. In this study, we investigated the effect of different reconstruction methods on RC values for 177Lu SPECT/CT images. A water-filled cylindrical polymethylmethacrylate (PMMA) phantom without background radioactivity with two solid cylinders which represent the bone and soft tissue equivalent was used for SPECT/CT imaging. We placed syringes with different volumes containing 177Lu in the vicinity of the cylinders as tumors. The iterative reconstructions of xSPECT, xSPECT Bone, and Flash3D was performed on SPECT/CT images.The effect of the reconstruction algorithms on the RC values was determined by calculating the radioactivity concentration in volumes of interest which were drawn manually and by a threshold method. The xSPECT Bone reconstruction has shown an RC value of approximately 100%, while the other reconstructions typically show an RC value of 93%. The RC values for all the reconstructions were decreased for smaller tumors. The smallest tumor showed a minimum RC between 52% and 72% compared to the largest tumor. In this study, it was possible to obtain an RC value close to 100% when the xSPECT Bone reconstruction algorithm was used. The xSPECT results were slightly lower RC values compared to the Flash3D algorithm. In using standard RC curves for tumors close to the bone, special care has to be taken since RC values relative to bone are higher than in tissue. * (These two authors share last authorship) Received: 28 April 2023 Accepted after revision: 18 September 2024 Article published online: 11 December 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 11 December 2024
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 64 (02) , 132-140
The impact of the xSPECT reconstruction algorithms on the recovery coefficients value for small tumors: a phantom study with 177Lu
Quantifying small tumors is still a challenge due to the partial volume effect (PVE). Although iterative reconstruction had promising results with a better recovery coefficient (RC), it suffers from the PVE. RC values typically depend on the reconstruction method, which may affect on 177Lu quantifying. In this study, we investigated the effect of different reconstruction methods on RC values for 177Lu SPECT/CT images. A water-filled cylindrical polymethylmethacrylate (PMMA) phantom without background radioactivity with two solid cylinders which represent the bone and soft tissue equivalent was used for SPECT/CT imaging. We placed syringes with different volumes containing 177Lu in the vicinity of the cylinders as tumors. The iterative reconstructions of xSPECT, xSPECT Bone, and Flash3D was performed on SPECT/CT images.The effect of the reconstruction algorithms on the RC values was determined by calculating the radioactivity concentration in volumes of interest which were drawn manually and by a threshold method. The xSPECT Bone reconstruction has shown an RC value of approximately 100%, while the other reconstructions typically show an RC value of 93%. The RC values for all the reconstructions were decreased for smaller tumors. The smallest tumor showed a minimum RC between 52% and 72% compared to the largest tumor. In this study, it was possible to obtain an RC value close to 100% when the xSPECT Bone reconstruction algorithm was used. The xSPECT results were slightly lower RC values compared to the Flash3D algorithm. In using standard RC curves for tumors close to the bone, special care has to be taken since RC values relative to bone are higher than in tissue. * (These two authors share last authorship) Received: 28 April 2023 Accepted after revision: 18 September 2024 Article published online: 11 December 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 15 March 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3701-3718
Design and performance evaluation of a slit‐slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study
PurposeWe investigated the design of a prompt gamma camera for real-time dose delivery verification and the partial mitigation of range uncertainties. MethodsA slit slat (SS) camera was optimized using the trade-off between the signal-to-noise ratio and spatial resolution. Then, using the GATE Monte Carlo package, the camera performances were estimated by means of target shifts, beam position quantification, changing the camera distance from the beam, and air cavity inserting. A homogeneous PMMA phantom and the air gaps induced PMMA phantom were used. The air gaps ranged from 5 mm to 30 mm by 5 mm increments were positioned in the middle of the beam range. To reduce the simulation time, phase space scoring was used. The batch method with five realizations was used for stochastic error calculations. ResultsThe system's detection efficiency was 1.1x10-4PGsEmittedPGs(1.8x10-5 PGs/proton) for a 10 x 20 cm(2) detector (source-to-collimator distance = 15.0 cm). Axial and transaxial resolutions were 23 mm and 18 mm, respectively. The SS camera estimated the range as 69.0 +/- 3.4 (relative stochastic error 1-sigma is 5%) and 67.6 +/- 1.8 mm (2.6%) for the real range of 67.0 mm for 10(7) and 10(8) protons of 100 MeV, respectively. Considering 160 MeV, these values are 155.5 +/- 3.1 (2%) and 152.2 +/- 2.0 mm (1.3%) for the real range of 152.0 mm for 10(7) and 10(8) protons, respectively. Considering phantom shift, for a 100 MeV beam, the precision of the quantification (1-sigma) in the axial and lateral phantom shift estimation is 2.6 mm and 1 mm, respectively. Accordingly, the axial and lateral quantification precisions were 1.3 mm and 1 mm for a 160 MeV beam, respectively. Furthermore, the quantification of an air gap formulated as gapdet=0.98xgapreal and gap(real) are the estimated and real air gap, respectively. The precision of the air gap quantification is 1.6 mm (1 sigma). Moreover, 2D PG images show the trajectory of the proton beam through the phantom. ConclusionThe proposed slit-slat imaging systems can potentially provide a real-time, in-vivo, and non-invasive treatment monitoring method for proton therapy.
- 15 March 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3701-3718
Design and performance evaluation of a slit‐slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study
PurposeWe investigated the design of a prompt gamma camera for real-time dose delivery verification and the partial mitigation of range uncertainties. MethodsA slit slat (SS) camera was optimized using the trade-off between the signal-to-noise ratio and spatial resolution. Then, using the GATE Monte Carlo package, the camera performances were estimated by means of target shifts, beam position quantification, changing the camera distance from the beam, and air cavity inserting. A homogeneous PMMA phantom and the air gaps induced PMMA phantom were used. The air gaps ranged from 5 mm to 30 mm by 5 mm increments were positioned in the middle of the beam range. To reduce the simulation time, phase space scoring was used. The batch method with five realizations was used for stochastic error calculations. ResultsThe system's detection efficiency was 1.1x10-4PGsEmittedPGs(1.8x10-5 PGs/proton) for a 10 x 20 cm(2) detector (source-to-collimator distance = 15.0 cm). Axial and transaxial resolutions were 23 mm and 18 mm, respectively. The SS camera estimated the range as 69.0 +/- 3.4 (relative stochastic error 1-sigma is 5%) and 67.6 +/- 1.8 mm (2.6%) for the real range of 67.0 mm for 10(7) and 10(8) protons of 100 MeV, respectively. Considering 160 MeV, these values are 155.5 +/- 3.1 (2%) and 152.2 +/- 2.0 mm (1.3%) for the real range of 152.0 mm for 10(7) and 10(8) protons, respectively. Considering phantom shift, for a 100 MeV beam, the precision of the quantification (1-sigma) in the axial and lateral phantom shift estimation is 2.6 mm and 1 mm, respectively. Accordingly, the axial and lateral quantification precisions were 1.3 mm and 1 mm for a 160 MeV beam, respectively. Furthermore, the quantification of an air gap formulated as gapdet=0.98xgapreal and gap(real) are the estimated and real air gap, respectively. The precision of the air gap quantification is 1.6 mm (1 sigma). Moreover, 2D PG images show the trajectory of the proton beam through the phantom. ConclusionThe proposed slit-slat imaging systems can potentially provide a real-time, in-vivo, and non-invasive treatment monitoring method for proton therapy.
- 14 August 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 188, 110405
Outcomes following transarterial radioembolization with 90Y and nanoparticles loaded resin microspheres
- 14 August 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 188, 110405
Outcomes following transarterial radioembolization with 90Y and nanoparticles loaded resin microspheres
- 23 February 2022
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 36 (5) , 479-487
Role of nanoparticles in transarterial radioembolization with glass microspheres
Objective Transarterial Radioembolization (TARE) with 90Y-loaded glass microspheres is a locoregional treatment option for Hepatocellular Carcinoma (HCC). Post-treatment 90Y bremsstrahlung imaging using Single-Photon Emission Tomography (SPECT) is currently a gold-standard imaging modality for quantifying the delivered dose. However, the nature of bremsstrahlung photons causes difficulty for dose estimation using SPECT imaging. This work aimed to investigate the possibility of using glass microspheres loaded with 90Y and Nanoparticles (NPs) to improve the quantification of delivered doses. Methods The Monte Carlo codes were used to simulate the post-TARE 90Y planar imaging. Planar images from bremsstrahlung photons and characteristic X-rays are acquired when 0, 1.2 mol/L, 2.4 mol/L, and 4.8 mol/L of Gold (Au), Hafnium (Hf), and Gadolinium (Gd) NPs are incorporated into the glass microspheres. We evaluated the quality of acquired images by calculating sensitivity and Signal-to-Background Ratio (SBR). Therapeutic effects of NPs were evaluated by calculation of Dose Enhancement Ratio (DER) in tumoral and non-tumoral liver tissues. Results The in silico results showed that the sensitivity values of bremsstrahlung and characteristic X-ray planar images increased significantly as the NPs concentration increased in the glass microspheres. The SBR values decreased as the NPs concentration increased for the bremsstrahlung planar images. In contrast, the SBR values increased for the characteristic X-ray planar images when Hf and Gd were incorporated into the glass microspheres. The DER values decreased in the tumoral and non-tumoral liver tissues as the NPs concentration increased. The maximum dose reduction was observed at the NPs concentration of 4.8 mol/L (≈ 7%). Conclusions The incorporation of Au, Hf, and Gd NPs into the glass microspheres improved the quality and quantity of post-TARE planar images. Also, treatment efficiency was decreased significantly at NPs concentration > 4.8 mol/L.
- 23 February 2022
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 36 (5) , 479-487
Role of nanoparticles in transarterial radioembolization with glass microspheres
Objective Transarterial Radioembolization (TARE) with 90Y-loaded glass microspheres is a locoregional treatment option for Hepatocellular Carcinoma (HCC). Post-treatment 90Y bremsstrahlung imaging using Single-Photon Emission Tomography (SPECT) is currently a gold-standard imaging modality for quantifying the delivered dose. However, the nature of bremsstrahlung photons causes difficulty for dose estimation using SPECT imaging. This work aimed to investigate the possibility of using glass microspheres loaded with 90Y and Nanoparticles (NPs) to improve the quantification of delivered doses. Methods The Monte Carlo codes were used to simulate the post-TARE 90Y planar imaging. Planar images from bremsstrahlung photons and characteristic X-rays are acquired when 0, 1.2 mol/L, 2.4 mol/L, and 4.8 mol/L of Gold (Au), Hafnium (Hf), and Gadolinium (Gd) NPs are incorporated into the glass microspheres. We evaluated the quality of acquired images by calculating sensitivity and Signal-to-Background Ratio (SBR). Therapeutic effects of NPs were evaluated by calculation of Dose Enhancement Ratio (DER) in tumoral and non-tumoral liver tissues. Results The in silico results showed that the sensitivity values of bremsstrahlung and characteristic X-ray planar images increased significantly as the NPs concentration increased in the glass microspheres. The SBR values decreased as the NPs concentration increased for the bremsstrahlung planar images. In contrast, the SBR values increased for the characteristic X-ray planar images when Hf and Gd were incorporated into the glass microspheres. The DER values decreased in the tumoral and non-tumoral liver tissues as the NPs concentration increased. The maximum dose reduction was observed at the NPs concentration of 4.8 mol/L (≈ 7%). Conclusions The incorporation of Au, Hf, and Gd NPs into the glass microspheres improved the quality and quantity of post-TARE planar images. Also, treatment efficiency was decreased significantly at NPs concentration > 4.8 mol/L.
- Open Access
- 1 January 2022
- Published by American Institute of Mathematical Sciences (AIMS) in AIMS Biophysics
- Vol. 9 (2) , 147-160
High-resolution phantom of a nephron for radiation nephrotoxicity evaluation in biophysical simulations
Computer simulation plays an important role in medical physics. The aim of this study was to generate an accurate model to calculate the absorbed dose at the cell level in a voxelized phantom of nephrons. In order to implement a model of kidney microdosimetry, a 3D mesh phantom of a human kidney nephron, representing a cortical nephron, was digitized to create a 3D voxelized phantom of a nephron for use in Monte Carlo simulations. The phantom was fed to GATE Monte Carlo toolkits, and simulations were performed to calculate the absorbed dose/energy from alpha and electron sources over a range of energy levels. The results were compared to the results published in literature that were derived by using a stylized phantom. The dose estimated in subunits of the voxelized and stylized phantoms showed a considerable bias (average of relative differences). The maximum difference for self-absorption was 12.5%, and up to 20% for cross-absorption. The digital phantom showed very significant differences in dose distribution among the cells in different subunits of the nephron. The results demonstrated that a small dissimilarity in the size and shape of subunits can lead to a considerable difference in the microdosimetry results. The model presented in this study offers a phantom that not only presents the realistic geometry of a nephron, which has been neglected in previous stylized models, but also one that has the capability of plotting the spatial distribution of the absorbed dose for any distribution of radiopharmaceuticals in nephron cells.
- 1 January 2022
- Published by American Institute of Mathematical Sciences (AIMS) in AIMS Biophysics
- Vol. 9 (2) , 147-160
Open AccessHigh-resolution phantom of a nephron for radiation nephrotoxicity evaluation in biophysical simulations
Computer simulation plays an important role in medical physics. The aim of this study was to generate an accurate model to calculate the absorbed dose at the cell level in a voxelized phantom of nephrons. In order to implement a model of kidney microdosimetry, a 3D mesh phantom of a human kidney nephron, representing a cortical nephron, was digitized to create a 3D voxelized phantom of a nephron for use in Monte Carlo simulations. The phantom was fed to GATE Monte Carlo toolkits, and simulations were performed to calculate the absorbed dose/energy from alpha and electron sources over a range of energy levels. The results were compared to the results published in literature that were derived by using a stylized phantom. The dose estimated in subunits of the voxelized and stylized phantoms showed a considerable bias (average of relative differences). The maximum difference for self-absorption was 12.5%, and up to 20% for cross-absorption. The digital phantom showed very significant differences in dose distribution among the cells in different subunits of the nephron. The results demonstrated that a small dissimilarity in the size and shape of subunits can lead to a considerable difference in the microdosimetry results. The model presented in this study offers a phantom that not only presents the realistic geometry of a nephron, which has been neglected in previous stylized models, but also one that has the capability of plotting the spatial distribution of the absorbed dose for any distribution of radiopharmaceuticals in nephron cells.
- 8 February 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (5) , N90-N106
A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S -values
The S -value is a standard measure in cellular dosimetry. S -values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these methods have been employed for estimation of cellular S -values, but there is no consistency between the published results. In the present paper, we used the Geant4-DNA track-structure physics model as the reference to estimate the cellular S -values. We compared the results with the corresponding values obtained from the following three condensed-history physics models of Geant4: Penelope, Livermore and standard. The geometry and source were exactly the same in all the simulations. We utilized mono-energetic electrons with an initial kinetic energy in the range 1–700 keV as the source of radiation. We also compared our results with the MIRD S -values. We first drew an overall comparison between different data series and then compared the dependence of results on the energy of particles and the size of scoring compartments. The overall comparison indicated a very good linear correlation ( R 2 > 91%) and small bias (3%) between the results of the track-structure model and the condensed-history physics model. The bias between MIRD and the results of Monte Carlo track-structure simulation was considerable (−8%). However, the point-by-point comparison revealed differences of up to 28% between the condensed-history and the track-structure MC codes for self-absorption S -values in the 10–50 keV energy range. For the cross-absorption S -values, the difference was up to 34%. In this energy range, the difference between the MIRD S -values and the Geant4-DNA results was up to 68%. Our findings suggest that the consistency/inconsistency of the results obtained with different MC simulations depends on the size of the scoring volumes, the energy of the particles, the step-size in electron tracking and the energy cutoff used in the MC codes.
- 8 February 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (5) , N90-N106
A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S -values
The S -value is a standard measure in cellular dosimetry. S -values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these methods have been employed for estimation of cellular S -values, but there is no consistency between the published results. In the present paper, we used the Geant4-DNA track-structure physics model as the reference to estimate the cellular S -values. We compared the results with the corresponding values obtained from the following three condensed-history physics models of Geant4: Penelope, Livermore and standard. The geometry and source were exactly the same in all the simulations. We utilized mono-energetic electrons with an initial kinetic energy in the range 1–700 keV as the source of radiation. We also compared our results with the MIRD S -values. We first drew an overall comparison between different data series and then compared the dependence of results on the energy of particles and the size of scoring compartments. The overall comparison indicated a very good linear correlation ( R 2 > 91%) and small bias (3%) between the results of the track-structure model and the condensed-history physics model. The bias between MIRD and the results of Monte Carlo track-structure simulation was considerable (−8%). However, the point-by-point comparison revealed differences of up to 28% between the condensed-history and the track-structure MC codes for self-absorption S -values in the 10–50 keV energy range. For the cross-absorption S -values, the difference was up to 34%. In this energy range, the difference between the MIRD S -values and the Geant4-DNA results was up to 68%. Our findings suggest that the consistency/inconsistency of the results obtained with different MC simulations depends on the size of the scoring volumes, the energy of the particles, the step-size in electron tracking and the energy cutoff used in the MC codes.
- 29 February 2016
- Published by Taylor & Francis in Synthesis and Reactivity in Inorganic, Metal-Organic, and Nano-Metal Chemistry
- Vol. 46 (10) , 1450-1454
Synthesis and Biological Evaluation of 99mTc-Chitosan Nanoparticles as a Potential Radiopharmaceutical for Liver Imaging
Nanoparticles are generally cleared by the reticuloendothelial system, taken up by Kupffer cells in liver. This principle can be used for liver imaging. Chitosan is an excellent biocompatible and biodegradable polymer. In this study, the authors synthesized 99mTc-chitosan nanoparticles and evaluated its potential for liver imaging. Chitosan nanoparticles were synthesized and radiolabeled with 99mTc. The labeling efficiency, stability, biodistribution, and imaging study in the normal mice was performed. Biodistribution and imaging studies demonstrated an efficient accumulation of the radiolabeled nanoparticles in the mice liver and indicated the 99mTc-chitosan nanoparticles may be considered as a promising radiopharmaceutical for liver imaging.
- 29 February 2016
- Published by Taylor & Francis in Synthesis and Reactivity in Inorganic, Metal-Organic, and Nano-Metal Chemistry
- Vol. 46 (10) , 1450-1454
Synthesis and Biological Evaluation of 99mTc-Chitosan Nanoparticles as a Potential Radiopharmaceutical for Liver Imaging
Nanoparticles are generally cleared by the reticuloendothelial system, taken up by Kupffer cells in liver. This principle can be used for liver imaging. Chitosan is an excellent biocompatible and biodegradable polymer. In this study, the authors synthesized 99mTc-chitosan nanoparticles and evaluated its potential for liver imaging. Chitosan nanoparticles were synthesized and radiolabeled with 99mTc. The labeling efficiency, stability, biodistribution, and imaging study in the normal mice was performed. Biodistribution and imaging studies demonstrated an efficient accumulation of the radiolabeled nanoparticles in the mice liver and indicated the 99mTc-chitosan nanoparticles may be considered as a promising radiopharmaceutical for liver imaging.
- 1 January 2012
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 42, 1292-1298
Radioimmunotherapy of mice bearing breast tumors with ^{177}Lu-labeled trastuzumab
In the present study, we investigated the therapeutic efficacy of trastuzumab labeled with lutetium-177 (^{177}Lu) in mice bearing breast tumors. Materials and methods: Trastuzumab was labeled with ^{177}Lu via DOTA as a chelator. In vitro and in vivo quality control tests of incorporated activity, immunoreactivity, stability of ^{177}Lu-trastuzumab, biodistribution, and imaging studies were performed. Therapeutic efficacy and dosimetry studies were carried out in mice with breast tumors. Results: The good in vitro and in vivo quality control results suggested that ^{177}Lu-trastuzumab could be used as a radioimmunotherapy agent. Reductions of 81% and 98% in the mean tumor volume for the group that received ^{177}Lu-trastuzumab [7.4 MBq] were observed at 42 and 45 days after treatment, respectively. Conclusion: The results showed that ^{177}Lu-trastuzumab could be considered as a possible new radiopharmaceutical agent for use in radioimmunotherapy of breast cancer in humans.
- 1 January 2012
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 42, 1292-1298
Radioimmunotherapy of mice bearing breast tumors with ^{177}Lu-labeled trastuzumab
In the present study, we investigated the therapeutic efficacy of trastuzumab labeled with lutetium-177 (^{177}Lu) in mice bearing breast tumors. Materials and methods: Trastuzumab was labeled with ^{177}Lu via DOTA as a chelator. In vitro and in vivo quality control tests of incorporated activity, immunoreactivity, stability of ^{177}Lu-trastuzumab, biodistribution, and imaging studies were performed. Therapeutic efficacy and dosimetry studies were carried out in mice with breast tumors. Results: The good in vitro and in vivo quality control results suggested that ^{177}Lu-trastuzumab could be used as a radioimmunotherapy agent. Reductions of 81% and 98% in the mean tumor volume for the group that received ^{177}Lu-trastuzumab [7.4 MBq] were observed at 42 and 45 days after treatment, respectively. Conclusion: The results showed that ^{177}Lu-trastuzumab could be considered as a possible new radiopharmaceutical agent for use in radioimmunotherapy of breast cancer in humans.