I. Dewa Gede Agung Junnaedhi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
I. Dewa Gede Agung Junnaedhi has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Manabu Kanda
Department of Transdisciplinary Science and Engineering, School of Environment and Society, Institute of Science Tokyo, Tokyo, 152-8552, Japan
6 shared publications- Alvin Christopher Galang Varquez
Department of Transdisciplinary Science and Engineering, School of Environment and Society, Institute of Science Tokyo, Tokyo, 152-8552, Japan
4 shared publications Atsushi Inagaki
Department of Transdisciplinary Science and Engineering, School of Environment and Society, Institute of Science Tokyo, Tokyo, 152-8552, Japan
4 shared publicationsDwina Nugraha
Earth Sciences Graduate Program, Faculty of Earth Sciences and Technology, Institut Teknologi Bandung, Bandung, 40132, Indonesia
4 shared publications- Muhammad Rais Abdillah
Atmospheric Sciences Research Group, Faculty of Earth Sciences and Technology, Institut Teknologi Bandung, Bandung, 40132, Indonesia
4 shared publications An Nur A. Muzasyaroh
Meteorology Undergraduate Program, Faculty of Earth Sciences and Technology, Institut Teknologi Bandung, Bandung, 40132, Indonesia
3 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-31
Reply on RC1
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- 23 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-31
Open AccessReply on RC1
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- Open Access
- 14 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-31
Comment on egusphere-2026-4598
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- 14 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-31
Open AccessComment on egusphere-2026-4598
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- Open Access
- 24 September 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-31
Design and Evaluation of a Low-Cost Horizontal Tube Radiation Shield for Temperature and Humidity Measurements in a Tropical Urban Environment
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- 24 September 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-31
Open AccessDesign and Evaluation of a Low-Cost Horizontal Tube Radiation Shield for Temperature and Humidity Measurements in a Tropical Urban Environment
Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.
- Open Access
- 11 July 2026
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (7)
Comparative Analysis of Future Urban Thermal Comfort in Three Cities Considering Urbanization Under Multiple CMIP6 Scenarios
This work investigates variations in thermal conditions in cities with different background climates exposed to climate change and future urbanization (i.e., horizontal/vertical urban expansion and energy consumption change). Simultaneously considering projected urbanization from the present to the 2050s, characterized by spatial changes in urban parameters and anthropogenic heat emissions (AHE), 1.5‐km present and future climates of Tokyo, Cairo, and Jakarta in the 2050s were modeled using initial and boundary conditions from the National Centers for Environmental Prediction Global Data Assimilation System/Final (NCEP GDAS/FNL) 0.25° Global Tropospheric Analyses and Forecast Grids and Coupled Model Intercomparison Project Phase 6 (CMIP6) climate‐change scenarios based on Shared Socioeconomic Pathways (SSP126, SSP245, and SSP370). The Universal Thermal Climate Index (UTCI) was estimated using the UTCI‐Fiala model. Regional near‐surface air temperature and UTCI scaled proportionally with background climate changes. Projected urbanization caused significant intra‐urban variability, with some locations showing warming comparable to background climate change. It also altered strong heat‐stress exposure, defined as hours with UTCI , amplifying exposure in Cairo and Jakarta but slightly offsetting it in Tokyo, where AHE declined. Cities with different background climates exhibited distinct seasonal responses: Tokyo showed moderate bimodal variability, Cairo exhibited the strongest variability with peak summer warming, and Jakarta showed a uniform increase year‐round. Near‐surface air temperature and UTCI responses to urbanization also varied seasonally across scenarios and cities, while variables beyond air temperature contributed to thermal‐comfort changes. This study strengthens the necessity of projecting not only meteorology, but also socially relevant indices, such as UTCI.
- 11 July 2026
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (7)
Open AccessComparative Analysis of Future Urban Thermal Comfort in Three Cities Considering Urbanization Under Multiple CMIP6 Scenarios
This work investigates variations in thermal conditions in cities with different background climates exposed to climate change and future urbanization (i.e., horizontal/vertical urban expansion and energy consumption change). Simultaneously considering projected urbanization from the present to the 2050s, characterized by spatial changes in urban parameters and anthropogenic heat emissions (AHE), 1.5‐km present and future climates of Tokyo, Cairo, and Jakarta in the 2050s were modeled using initial and boundary conditions from the National Centers for Environmental Prediction Global Data Assimilation System/Final (NCEP GDAS/FNL) 0.25° Global Tropospheric Analyses and Forecast Grids and Coupled Model Intercomparison Project Phase 6 (CMIP6) climate‐change scenarios based on Shared Socioeconomic Pathways (SSP126, SSP245, and SSP370). The Universal Thermal Climate Index (UTCI) was estimated using the UTCI‐Fiala model. Regional near‐surface air temperature and UTCI scaled proportionally with background climate changes. Projected urbanization caused significant intra‐urban variability, with some locations showing warming comparable to background climate change. It also altered strong heat‐stress exposure, defined as hours with UTCI , amplifying exposure in Cairo and Jakarta but slightly offsetting it in Tokyo, where AHE declined. Cities with different background climates exhibited distinct seasonal responses: Tokyo showed moderate bimodal variability, Cairo exhibited the strongest variability with peak summer warming, and Jakarta showed a uniform increase year‐round. Near‐surface air temperature and UTCI responses to urbanization also varied seasonally across scenarios and cities, while variables beyond air temperature contributed to thermal‐comfort changes. This study strengthens the necessity of projecting not only meteorology, but also socially relevant indices, such as UTCI.
- Open Access
- 2 March 2026
- Published by Wiley
Synoptic Drivers of Tropical Cyclone Senyar and Long-term Change in Near-Equatorial Tropical Cyclones over the Maritime Continent
Tropical Cyclone (TC) Senyar was a rare near-equatorial TC that severely impacted the western Maritime Continent (MC). It formed within the narrow Malacca Strait under weak Coriolis forcing, indicating the critical role of synoptic-scale forcing in cyclogenesis. Northeasterly cold surges accompanied its development, resembling those during Typhoon Vamei in 2001, but with a stronger easterly component that redirected moisture toward the Malacca Strait. Simultaneously, strengthened westerlies over the eastern Indian Ocean associated with a negative Indian Ocean Dipole persisted. The convergence of easterlies and westerlies around a background positive vorticity continuously intensified the initial vortex and influenced the TC propagation. Analysis of two historical climate periods reveals a significant increase in near-equatorial TCs over the MC, underscoring the growing importance of understanding TC dynamics and impacts in the region.
- 2 March 2026
- Published by Wiley
Open AccessSynoptic Drivers of Tropical Cyclone Senyar and Long-term Change in Near-Equatorial Tropical Cyclones over the Maritime Continent
Tropical Cyclone (TC) Senyar was a rare near-equatorial TC that severely impacted the western Maritime Continent (MC). It formed within the narrow Malacca Strait under weak Coriolis forcing, indicating the critical role of synoptic-scale forcing in cyclogenesis. Northeasterly cold surges accompanied its development, resembling those during Typhoon Vamei in 2001, but with a stronger easterly component that redirected moisture toward the Malacca Strait. Simultaneously, strengthened westerlies over the eastern Indian Ocean associated with a negative Indian Ocean Dipole persisted. The convergence of easterlies and westerlies around a background positive vorticity continuously intensified the initial vortex and influenced the TC propagation. Analysis of two historical climate periods reveals a significant increase in near-equatorial TCs over the MC, underscoring the growing importance of understanding TC dynamics and impacts in the region.
- Open Access
- 21 May 2025
- Published by Copernicus GmbH
Statistical downscaling into the airflows within urban districts based on a numerical simulation datasets
Pedestrian level wind environment is closely related to pedestrian comforts regarding the air quality, thermal comfort, wind load, etc. Now a day, computational fluid dynamic models can successfully simulate the airflows at an urban street scale. However, it still takes much computational costs to run daily similar with the operational weather forecasts.This study conducts a diagnostic prediction of the microscale wind environment based on the statistical downscaling. This statistical downscaling requires the relationship between the regional meteorological parameters between a coarse grid and local meteorological parameters to be refined. The refined grid is produced by lattice Boltzmann equation model simulations performed on a huge GPU cluster (TSUBAME4.0). Simple linear relationships between the local wind environment and the regional meteorological parameters were observed.Based on this empirical relationship, the few-meter scale fine velocity distribution within an urban district was reproduced which was downscaled from the regional meteorological observation. The results were compared with the several near-ground observation points in urban districts. A good correlation between the measured and diagnostically estimated velocity distributions was confirmed.In addition, the regional meteorological data was also replaced by the output of regional weather forecasting model, which the result can also confirm the reproduction of the microscale wind environment
- 21 May 2025
- Published by Copernicus GmbH
Open AccessStatistical downscaling into the airflows within urban districts based on a numerical simulation datasets
Pedestrian level wind environment is closely related to pedestrian comforts regarding the air quality, thermal comfort, wind load, etc. Now a day, computational fluid dynamic models can successfully simulate the airflows at an urban street scale. However, it still takes much computational costs to run daily similar with the operational weather forecasts.This study conducts a diagnostic prediction of the microscale wind environment based on the statistical downscaling. This statistical downscaling requires the relationship between the regional meteorological parameters between a coarse grid and local meteorological parameters to be refined. The refined grid is produced by lattice Boltzmann equation model simulations performed on a huge GPU cluster (TSUBAME4.0). Simple linear relationships between the local wind environment and the regional meteorological parameters were observed.Based on this empirical relationship, the few-meter scale fine velocity distribution within an urban district was reproduced which was downscaled from the regional meteorological observation. The results were compared with the several near-ground observation points in urban districts. A good correlation between the measured and diagnostically estimated velocity distributions was confirmed.In addition, the regional meteorological data was also replaced by the output of regional weather forecasting model, which the result can also confirm the reproduction of the microscale wind environment
- Open Access
- 12 June 2023
- Published by Wiley in International Journal of Climatology
- Vol. 43 (11) , 5177-5195
Seasonal sea breeze variation analysis based on multi‐year near‐surface observations in Jakarta, Indonesia
In this study, multi‐year near‐surface observations were conducted at two sites in Jakarta, Indonesia to analyse seasonal sea breeze variation. Seasonal length was defined using observed zonal wind components, the rainy season was defined as December–March, and the dry season was defined as May–September. We found that the sea breeze in Jakarta started earlier, propagated more rapidly, and lasted for a shorter period of time during the rainy than dry season. Variation in the air temperature difference between urban and coastal areas of Jakarta was the major factor driving sea breeze seasonal variation. During the rainy season, night‐time cloud downwelling decreased this air temperature difference, causing earlier sea breeze onset and more rapid sea breeze propagation due to a weaker land breeze. By contrast, during the dry season, intense night‐time radiative cooling inland caused a strong negative temperature difference that produced a stronger land breeze, thus, slowing sea breeze propagation. Seasonal differences in urban surface heating and urban heat island circulation may also affect sea breeze onset and propagation speed. Discrepancies in thermal properties between urban core and coastal areas of Jakarta also prolonged positive temperature differences after sunset, thus extending the sea breeze duration in the dry season.
- 12 June 2023
- Published by Wiley in International Journal of Climatology
- Vol. 43 (11) , 5177-5195
Open AccessSeasonal sea breeze variation analysis based on multi‐year near‐surface observations in Jakarta, Indonesia
In this study, multi‐year near‐surface observations were conducted at two sites in Jakarta, Indonesia to analyse seasonal sea breeze variation. Seasonal length was defined using observed zonal wind components, the rainy season was defined as December–March, and the dry season was defined as May–September. We found that the sea breeze in Jakarta started earlier, propagated more rapidly, and lasted for a shorter period of time during the rainy than dry season. Variation in the air temperature difference between urban and coastal areas of Jakarta was the major factor driving sea breeze seasonal variation. During the rainy season, night‐time cloud downwelling decreased this air temperature difference, causing earlier sea breeze onset and more rapid sea breeze propagation due to a weaker land breeze. By contrast, during the dry season, intense night‐time radiative cooling inland caused a strong negative temperature difference that produced a stronger land breeze, thus, slowing sea breeze propagation. Seasonal differences in urban surface heating and urban heat island circulation may also affect sea breeze onset and propagation speed. Discrepancies in thermal properties between urban core and coastal areas of Jakarta also prolonged positive temperature differences after sunset, thus extending the sea breeze duration in the dry season.
- Open Access
- 20 June 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 71 (1) , 012003
Comparison landslide-triggering rainfall threshold using satellite data: TRMM and GPM in South Bandung area
The number of landslides events in Bandung ranked fourth in Indonesia. The landslide is affected not only by the geographical character, but also by the rainfall intensity and duration. Thus, the information of the threshold of landslide triggering rainfall is important to be obtained. This study is aim to determine the threshold of rainfall in South Bandung using rainfall data provided by TRMM and GPM satellites. The satellite data is corrected by ground-observation data in three sites. The empirical method used in this study performs the relationship between the rainfall intensity and duration to the landslide event and the threshold curve obtained by lowering the regression line intensity-duration (ID) to lowest point rainfall in causing the landslide. The relationship of rainfall ID for landslide threshold is expressed in I= 2.3 e (-0.03*D) for TRMM data, while I= 7.20 e (-0.09*D) for GPM data. The result shows that the GPM data better than TRMM data and the analysis of measurement data showed a pattern corresponding to the observed values.
- 20 June 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 71 (1) , 012003
Open AccessComparison landslide-triggering rainfall threshold using satellite data: TRMM and GPM in South Bandung area
The number of landslides events in Bandung ranked fourth in Indonesia. The landslide is affected not only by the geographical character, but also by the rainfall intensity and duration. Thus, the information of the threshold of landslide triggering rainfall is important to be obtained. This study is aim to determine the threshold of rainfall in South Bandung using rainfall data provided by TRMM and GPM satellites. The satellite data is corrected by ground-observation data in three sites. The empirical method used in this study performs the relationship between the rainfall intensity and duration to the landslide event and the threshold curve obtained by lowering the regression line intensity-duration (ID) to lowest point rainfall in causing the landslide. The relationship of rainfall ID for landslide threshold is expressed in I= 2.3 e (-0.03*D) for TRMM data, while I= 7.20 e (-0.09*D) for GPM data. The result shows that the GPM data better than TRMM data and the analysis of measurement data showed a pattern corresponding to the observed values.