Shirin Azadi Kenari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shirin Azadi Kenari has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Joost C. Lotters
MESA+ Institute for Nanotechnology, University of Twente, 7522 NB Enschede, The Netherlands
2 shared publications - Remco G. P. Sanders
Integrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands
2 shared publications - Remco John Wiegerink
MESA+ Institute, University of Twente, Enschede, The Netherlands
2 shared publications - Henk-Willem Veltkamp
MESA+ Institute for Nanotechnology, University of Twente, 7522 NB Enschede, The Netherlands
1 shared publication J C Lötters
Bronkhorst High Tech BV, NL-7261 AK Ruurlo, Netherlands
1 shared publicationJoost C. Lotters
University of Twente,the Netherlands
1 shared publication
Latest Publications
- Open Access
- 13 December 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (1) , 015003
Gas-compensated thermal flow sensor using an integrated velocity-independent gas properties meter
A gas-compensated thermal flow sensor is presented that measures the flow rate in real-time, independent of the type of gas, by simultaneously measuring and compensating for the thermal conductivity and volumetric heat capacity of the gas. The thermal flow sensor consists of two free-hanging, heated wires, forming a calorimetric flow meter. The temperature difference between the two wires is a function of the flow rate and the fluid thermal properties. An additional heated wire is integrated on the same chip and used to measure the gas properties. This wire is suspended over a shallow V-groove cavity, and oriented perpendicular to the flow direction, so that it is only affected by the gas properties and not by the flow. DC excitation is used to measure the thermal conductivity, and AC excitation with the 3ω method is used to determine the volumetric heat capacity. The output of the thermal flow sensor is automatically corrected for the medium using these measured parameters. Measurements were performed with 11 different gases and gas mixtures, and in all cases the deviation between the applied flow rate and measured flow rate is less than 10%.
- 13 December 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (1) , 015003
Open AccessGas-compensated thermal flow sensor using an integrated velocity-independent gas properties meter
A gas-compensated thermal flow sensor is presented that measures the flow rate in real-time, independent of the type of gas, by simultaneously measuring and compensating for the thermal conductivity and volumetric heat capacity of the gas. The thermal flow sensor consists of two free-hanging, heated wires, forming a calorimetric flow meter. The temperature difference between the two wires is a function of the flow rate and the fluid thermal properties. An additional heated wire is integrated on the same chip and used to measure the gas properties. This wire is suspended over a shallow V-groove cavity, and oriented perpendicular to the flow direction, so that it is only affected by the gas properties and not by the flow. DC excitation is used to measure the thermal conductivity, and AC excitation with the 3ω method is used to determine the volumetric heat capacity. The output of the thermal flow sensor is automatically corrected for the medium using these measured parameters. Measurements were performed with 11 different gases and gas mixtures, and in all cases the deviation between the applied flow rate and measured flow rate is less than 10%.
- Open Access
- 21 May 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 671
Flow-Independent Thermal Conductivity and Volumetric Heat Capacity Measurement of Pure Gases and Binary Gas Mixtures Using a Single Heated Wire
Among the different techniques for monitoring the flow rate of various fluids, thermal flow sensors stand out for their straightforward measurement technique. However, the main drawback of these types of sensors is their dependency on the thermal properties of the medium, i.e., thermal conductivity (k), and volumetric heat capacity (). They require calibration whenever the fluid in the system changes. In this paper, we present a single hot wire suspended above a V-groove cavity that is used to measure k and through DC and AC excitation for both pure gases and binary gas mixtures, respectively. The unique characteristic of the proposed sensor is its independence of the flow velocity, which makes it possible to detect the medium properties while the fluid flows over the sensor chip. The measured error due to fluctuations in flow velocity is less than ±0.5% for all test gases except for He, where it is ±6% due to the limitations of the measurement setup. The working principle and measurement results are discussed.- 21 May 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 671
Open AccessFlow-Independent Thermal Conductivity and Volumetric Heat Capacity Measurement of Pure Gases and Binary Gas Mixtures Using a Single Heated Wire
Among the different techniques for monitoring the flow rate of various fluids, thermal flow sensors stand out for their straightforward measurement technique. However, the main drawback of these types of sensors is their dependency on the thermal properties of the medium, i.e., thermal conductivity (k), and volumetric heat capacity (). They require calibration whenever the fluid in the system changes. In this paper, we present a single hot wire suspended above a V-groove cavity that is used to measure k and through DC and AC excitation for both pure gases and binary gas mixtures, respectively. The unique characteristic of the proposed sensor is its independence of the flow velocity, which makes it possible to detect the medium properties while the fluid flows over the sensor chip. The measured error due to fluctuations in flow velocity is less than ±0.5% for all test gases except for He, where it is ±6% due to the limitations of the measurement setup. The working principle and measurement results are discussed. - Open Access
- 21 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1280
Thermal Flow Meter with Integrated Thermal Conductivity Sensor
This paper presents a novel gas-independent thermal flow sensor chip featuring three calorimetric flow sensors for measuring flow profile and direction within a tube, along with a single-wire flow independent thermal conductivity sensor capable of identifying the gas type through a simple DC voltage measurement. All wires have the same dimensions of 2000 m in length, 5 m in width, and 1.2 m in thickness. The design theory and COMSOL simulation are discussed and compared with the measurement results. The sensor’s efficacy is demonstrated with different gases, He, N2, Ar, and CO2, for thermal conductivity and thermal flow measurements. The sensor can accurately measure the thermal conductivity of various gases, including air, enabling correction of flow rate measurements based on the fluid type. The measured voltage from the thermal conductivity sensor for air corresponds to a calculated thermal conductivity of 0.02522 [W/m·K], with an error within 2.9%.- 21 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1280
Open AccessThermal Flow Meter with Integrated Thermal Conductivity Sensor
This paper presents a novel gas-independent thermal flow sensor chip featuring three calorimetric flow sensors for measuring flow profile and direction within a tube, along with a single-wire flow independent thermal conductivity sensor capable of identifying the gas type through a simple DC voltage measurement. All wires have the same dimensions of 2000 m in length, 5 m in width, and 1.2 m in thickness. The design theory and COMSOL simulation are discussed and compared with the measurement results. The sensor’s efficacy is demonstrated with different gases, He, N2, Ar, and CO2, for thermal conductivity and thermal flow measurements. The sensor can accurately measure the thermal conductivity of various gases, including air, enabling correction of flow rate measurements based on the fluid type. The measured voltage from the thermal conductivity sensor for air corresponds to a calculated thermal conductivity of 0.02522 [W/m·K], with an error within 2.9%. - 15 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 767-770
Towards a Gas Independent Thermal Flow Meter
We present a novel potentially gas-independent thermal flow sensor chip that contains three two-wire calorimetric flow sensors to measure the flow profile and flow direction inside a tube, and a single-wire flow-independent thermal conductivity sensor which detects the type of the gas through a simple DC voltage measurement. All wires have the same dimensions of 2000 µm in length, 5 µm in width and 1.2 µm in thickness. Four different gases Ar, N 2 , Ne and He were used for the thermal conductivity measurement and the measured output voltage corresponds very well with a theoretical model.
- 15 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 767-770
Towards a Gas Independent Thermal Flow Meter
We present a novel potentially gas-independent thermal flow sensor chip that contains three two-wire calorimetric flow sensors to measure the flow profile and flow direction inside a tube, and a single-wire flow-independent thermal conductivity sensor which detects the type of the gas through a simple DC voltage measurement. All wires have the same dimensions of 2000 µm in length, 5 µm in width and 1.2 µm in thickness. Four different gases Ar, N 2 , Ne and He were used for the thermal conductivity measurement and the measured output voltage corresponds very well with a theoretical model.