Joost C. Lotters has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Micro Coriolis Mass Flow Sensor with Large Channel Diameter Realized by HNA Wet Etching

    by Qihui Yu, Maarten J. S. Bonnema, Mahdieh Yariesbouei, Remco J. Wiegerink, Joost C. Lötters

    This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area. Because of this larger cross-sectional area, the sensor has a much higher flow range, up to 50 g h−1 (for water) with a pressure drop of 1 bar, compared to the standard SCT-based Coriolis sensor, which is only 1.2 g h−1. The channel has a semi-elliptical cross-sectional area, measuring 200 micrometers wide and 70 micrometers deep. The channel wall is made of a stack of thin films with a total thickness of 2.5 μm. Water, isopropyl alcohol (IPA), and nitrogen (N2) are used to test and evaluate the sensor’s mass flow and density sensing performance.


  • Open Access

    Fabrication of Buried Microchannels with Almost Circular Cross-Section Using HNA Wet Etching

    by Qihui Yu, Henk-Willem Veltkamp, Remco J. Wiegerink, Joost C. Lötters

    In this paper, a novel fabrication process for the realization of large, suspended microfluidic channels is presented. The method is based on Buried Channel Technology and uses a mixture of HF, HNO3, and water etchant, which has high selectivity between the silicon substrate and the silicon-rich silicon nitride mask material. Metal electrodes for actuation and read-out are integrated into the fabrication process. The microfluidic channels are released from the silicon substrate to allow the vibrational movement needed for the application. The resulting microfluidic channels have a near-circular cross-section, with a diameter up to 300 μm and a channel wall thickness of 1.5 μm. The structure of a micro-Coriolis mass-flow and density sensor is fabricated with this process as an example of a possible application.


  • Open Access

    Flow-Independent Thermal Conductivity and Volumetric Heat Capacity Measurement of Pure Gases and Binary Gas Mixtures Using a Single Heated Wire

    by Shirin Azadi Kenari, Remco J. Wiegerink, Remco G. P. Sanders, Joost C. Lötters

    Among the different techniques for monitoring the flow rate of various fluids, thermal flow sensors stand out for their straightforward measurement technique. However, the main drawback of these types of sensors is their dependency on the thermal properties of the medium, i.e., thermal conductivity (k), and volumetric heat capacity (ρcp). They require calibration whenever the fluid in the system changes. In this paper, we present a single hot wire suspended above a V-groove cavity that is used to measure k and ρcp through DC and AC excitation for both pure gases and binary gas mixtures, respectively. The unique characteristic of the proposed sensor is its independence of the flow velocity, which makes it possible to detect the medium properties while the fluid flows over the sensor chip. The measured error due to fluctuations in flow velocity is less than ±0.5% for all test gases except for He, where it is ±6% due to the limitations of the measurement setup. The working principle and measurement results are discussed.


  • Open Access

    Compact Micro-Coriolis Mass-Flow Meter with Optical Readout

    by Mahdieh Yariesbouei, Remco G. P. Sanders, Remco J. Wiegerink, Joost C. Lötters

    This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 µm, and a wall thickness of approximately 8 µm. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of 0.41mdegg/h and 0.43 mdegg/h, respectively.


  • Open Access

    Thermal Flow Meter with Integrated Thermal Conductivity Sensor

    by Shirin Azadi Kenari, Remco J. Wiegerink, Henk-Willem Veltkamp, Remco G. P. Sanders, Joost C. Lötters

    This paper presents a novel gas-independent thermal flow sensor chip featuring three calorimetric flow sensors for measuring flow profile and direction within a tube, along with a single-wire flow independent thermal conductivity sensor capable of identifying the gas type through a simple DC voltage measurement. All wires have the same dimensions of 2000 μm in length, 5 μm in width, and 1.2 μm in thickness. The design theory and COMSOL simulation are discussed and compared with the measurement results. The sensor’s efficacy is demonstrated with different gases, He, N2, Ar, and CO2, for thermal conductivity and thermal flow measurements. The sensor can accurately measure the thermal conductivity of various gases, including air, enabling correction of flow rate measurements based on the fluid type. The measured voltage from the thermal conductivity sensor for air corresponds to a calculated thermal conductivity of 0.02522 [W/m·K], with an error within 2.9%.


  • Open Access

    Modeling, Fabrication, and Testing of a 3D-Printed Coriolis Mass Flow Sensor

    by Mahdieh Yariesbouei, Remco G. P. Sanders, Remco J. Wiegerink, Joost C. Lötters

    This paper presents the modeling, fabrication, and testing of a 3D-printed Coriolis mass flow sensor. The sensor contains a free-standing tube with a circular cross-section printed using the LCD 3D-printing technique. The tube has a total length of 42 mm, an inner diameter of about 900 µm, and a wall thickness of approximately 230 µm. The outer surface of the tube is metalized using a Cu plating process, resulting in a low electrical resistance of 0.5 Ω. The tube is brought into vibration using an AC current in combination with a magnetic field from a permanent magnet. The displacement of the tube is detected using a laser Doppler vibrometer (LDV) that is part of a Polytec MSA-600 microsystem analyzer. The Coriolis mass flow sensor has been tested over a flow range of 0–150 g/h for water, 0–38 g/h for isopropyl alcohol (IPA), and 0–50 g/h for nitrogen. The maximum flow rates of water and IPA resulted in less than a 30 mbar pressure drop. The pressure drop at the maximum flow rate of nitrogen is 250 mbar.


  • Open Access

    Method for Keyhole-Free High-Aspect-Ratio Trench Refill by LPCVD

    by Henk-Willem Veltkamp, Yves L. Janssens, Meint J. de Boer, Yiyuan Zhao, Remco J. Wiegerink, Niels R. Tas, Joost C. Lötters

    In micro-machined micro-electromechanical systems (MEMS), refilled high-aspect-ratio trench structures are used for different applications. However, these trenches often show keyholes, which have an impact on the performance of the devices. In this paper, explanations are given on keyhole formation, and a method is presented for etching positively-tapered high-aspect ratio trenches with an optimised trench entrance to prevent keyhole formation. The trench etch is performed by a two-step Bosch-based process, in which the cycle time, platen power, and process pressure during the etch step of the Bosch cycle are studied to adjust the dimensions of the scallops and their location in the trench sidewall, which control the taper of the trench sidewall. It is demonstrated that the amount of chemical flux, being adjusted by the cycle time of the etch step in the Bosch cycle, relates the scallop height to the sidewall profile angle. The required positive tapering of 88° to 89° for a keyhole-free structure after a trench refill by low-pressure chemical vapour deposition is achieved by lowering the time of the etch step.


  • Free Suspended Thin-Walled Nickel Electroplated Tubes for Microfluidic Density and Mass Flow Sensors

    by Mahdieh Yariesbouei, Remco G. P. Sanders, Taghi Moazzenzade, Remco J. Wiegerink, Joost C. Lotters

    In this paper, a novel fabrication method is proposed for microfluidic tubes with a large diameter, circular cross-section, and thin wall. These properties make the tubes especially suitable for density sensors and Coriolis mass flow sensors, because of the resulting low tube mass, low-pressure drop, and low pressure-dependence of the tube shape. A demonstrator sensor was fabricated and the first measurement results of fluid density and mass flow are presented. The low-cost fabrication method is based on electroplating technology and results in tubes with a near-perfect circular cross-section. Diameters ranging from 120 μm to 1 mm and wall thicknesses from 8 μm to 60 μm have been achieved. For the demonstrator sensor presented in this paper a freely suspended tube was realized with a total length of 37 mm, a diameter of 600 μm, and a wall thickness of 20 μm. Density measurements were performed using various gases, liquids, and liquid mixtures at 21°C to 23°C lab temperature. The accuracy of the measured densities of gases such as nitrogen, argon, and helium is 5%. For liquids including DI water, isopropyl alcohol (IPA), and their various mixtures an accuracy of 0.5% was obtained. Preliminary mass flow rate measurements were performed with water and isopropyl alcohol up to 30 g/h with less than 30 mbar pressure drop thanks to the large tube diameter. [2021-0179]


  • Open Access

    Air Damping Analysis of a Micro-Coriolis Mass Flow Sensor

    by Yaxiang Zeng, Remco Sanders, Remco J. Wiegerink, Joost C. Lötters

    A micro-Coriolis mass flow sensor is a resonating device that measures small mass flows of fluid. A large vibration amplitude is desired as the Coriolis forces due to mass flow and, accordingly, the signal-to-noise ratio, are directly proportional to the vibration amplitude. Therefore, it is important to maximize the quality factor Q so that a large vibration amplitude can be achieved without requiring high actuation voltages and high power consumption. This paper presents an investigation of the Q factor of different devices in different resonant modes. Q factors were measured both at atmospheric pressure and in vacuum. The measurement results are compared with theoretical predictions. In the atmospheric environment, the Q factor increases when the resonance frequency increases. When reducing the pressure from 1 bar to 0.1 bar, the Q factor almost doubles. At even lower pressures, the Q factor is inversely proportional to the pressure until intrinsic effects start to dominate, resulting in a maximum Q factor of approximately 7200.


  • μ-Coriolis Mass Flow Sensor With Differential Capacitive Readout

    by Thomas V. P. Schut, Remco J. Wiegerink, Joost C. Lotters

    In this paper we present a $\mu $ -Coriolis mass flow sensor with differential capacitive readout, which can reduce the effect of common mode vibrations caused by external disturbances. The device consists of two silicon nitride micro-channel loops mechanically connected through two membranes. The sensor is actuated using Lorentz forces, inducing rotation of the sensor's micro-channels. Coriolis forces of opposite sign are subsequently generated in the two channel loops. Thus, any common mode vibration can be distinguished from vibration induced by mass flow through the channels. Capacitive readout structures surround the sensor to detect these vibrations. A piezo-electric resonator is placed in close proximity to the sensor to generate artificial external disturbance. Flow measurements are executed to compare the differential readout method to a single ended readout with and without external disturbances. The flow sensitivity is unaffected. However, the mean deviation of the output signal is 60-70% lower when using the differential readout compared to single ended readout when external disturbances are induced. The effect of external disturbances on the zero flow stability is reduced by approximately 64% by using the differential readout. Full elimination of the effect is not possible due to non-linearity of the readout capacitors. Reducing non-linearity of the readout could further improve performance, e.g. by implementing (piezo-resistive) strain gauges on top of the micro-channel.