Zhenyao Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhenyao Ding has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Haili Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215000, China
1 shared publication - Jun Zhang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, China
1 shared publication - Lihui Huang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215000, China
1 shared publication - Man Zhang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215000, China
1 shared publication - Xinjian Feng
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
1 shared publication
Latest Publications
- Open Access
- 8 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 26
Laser-Induced Graphene Arrays-Based Three-Phase Interface Enzyme Electrode for Reliable Bioassays
Electrochemical oxidase biosensors have been widely applied in healthcare, environmental measurements and the biomedical field. However, the low and fluctuant oxygen levels in solution and the high anodic detection potentially restrict the assay accuracy. To address these problems, in this work, we constructed a three-phase interface enzyme electrode by sequentially immobilizing H2O2 electrocatalysts and an oxidase layer on a superhydrophobic laser-induced graphene (LIG) array substrate. The LIG-based enzyme electrode possesses a solid–liquid–air three-phase interface where constant and sufficient oxygen can be supplied from the air phase to the enzymatic reaction zone, which enhances and stabilizes the oxidase kinetics. We discovered that the enzymatic reaction rate is 21.2-fold improved over that of a solid–liquid diphase system where oxygen is supplied from the liquid phase, leading to a 60-times wider linear detection range. Moreover, the three-phase enzyme electrode can employ a cathodic measuring principle for oxidase catalytic product H2O2 detection, which could minimize interferences arising from oxidizable molecules in biofluids and increase the detection selectivity. This work provides a simple and promising approach to the design and construction of high-performance bioassay systems.
- 8 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 26
Open AccessLaser-Induced Graphene Arrays-Based Three-Phase Interface Enzyme Electrode for Reliable Bioassays
Electrochemical oxidase biosensors have been widely applied in healthcare, environmental measurements and the biomedical field. However, the low and fluctuant oxygen levels in solution and the high anodic detection potentially restrict the assay accuracy. To address these problems, in this work, we constructed a three-phase interface enzyme electrode by sequentially immobilizing H2O2 electrocatalysts and an oxidase layer on a superhydrophobic laser-induced graphene (LIG) array substrate. The LIG-based enzyme electrode possesses a solid–liquid–air three-phase interface where constant and sufficient oxygen can be supplied from the air phase to the enzymatic reaction zone, which enhances and stabilizes the oxidase kinetics. We discovered that the enzymatic reaction rate is 21.2-fold improved over that of a solid–liquid diphase system where oxygen is supplied from the liquid phase, leading to a 60-times wider linear detection range. Moreover, the three-phase enzyme electrode can employ a cathodic measuring principle for oxidase catalytic product H2O2 detection, which could minimize interferences arising from oxidizable molecules in biofluids and increase the detection selectivity. This work provides a simple and promising approach to the design and construction of high-performance bioassay systems.