Shankar Swarup Das
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Shankar Swarup Das has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Prasun Chakraborti
National Institute of Technology, Agartala
4 shared publications- Chiranjit Bhowmik
National Institute of Technology
2 shared publications - Malik Shadab
Materials for Energy and Environmental Laboratory, Superconducting Materials Group, Graduate School of Engineering and Science, Shibaura Institute of Technology , 3-7-5 Toyosu, Koto City, Tokyo 135-8548
1 shared publication P Chakraborti
1 shared publication- Prakash Kumar Sarangi
College of Agriculture, Central Agricultural University, Imphal 795004, India
1 shared publication - Prasun Chakraborti
Department of Mechanical Engineering, National Institute of Technology, Agartala, India
1 shared publication
Latest Publications
- 13 June 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 238 (6) , 2983-2993
Formulation and selection of composite biomaterials for acetabular cup of hip prosthesis with wear analysis
The study of tribological performance of metal-on-plastic type of hip prostheses has drawn the attention of researchers since the last few decades. These studies mainly focus on the friction and wear behaviour of acetabular cups made of different polymer biomaterials with a view to enhance the prostheses life. In this study, a novel biomaterial coded as LHHA has been prepared for the acetabular cup in three different blends with help of bioprocess engineering by mixing low-density polyethylene and high-density polyethylene with10, 20 and 30 percent of hydroxyapatite to improve the mechanical properties. A popular decision-making method was applied to select the best alternative from these three blends on the basis of hardness, roughness and ultimate strength and LHHA-30 is found to be the best. Furthermore, experimental wear investigation was carried out in a well-designed hip simulator to control such biological system under a series of random loads, within 600N and 1500N acting at different points on prosthesis for 10 million gait cycles run followed by theoretical wear analysis. Wear rates are found to be 12.651 and 26.247 mg per million cycle with marginal differences of 0.1 and 0.6 for LHHA-30 and ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups against cobalt–chromium (Co–Cr) alloy femoral head, respectively. Morphological studies carried out by scanning electron microscope revealed that LHHA-30 scored less compared to UHMWPE surface.
- 13 June 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 238 (6) , 2983-2993
Formulation and selection of composite biomaterials for acetabular cup of hip prosthesis with wear analysis
The study of tribological performance of metal-on-plastic type of hip prostheses has drawn the attention of researchers since the last few decades. These studies mainly focus on the friction and wear behaviour of acetabular cups made of different polymer biomaterials with a view to enhance the prostheses life. In this study, a novel biomaterial coded as LHHA has been prepared for the acetabular cup in three different blends with help of bioprocess engineering by mixing low-density polyethylene and high-density polyethylene with10, 20 and 30 percent of hydroxyapatite to improve the mechanical properties. A popular decision-making method was applied to select the best alternative from these three blends on the basis of hardness, roughness and ultimate strength and LHHA-30 is found to be the best. Furthermore, experimental wear investigation was carried out in a well-designed hip simulator to control such biological system under a series of random loads, within 600N and 1500N acting at different points on prosthesis for 10 million gait cycles run followed by theoretical wear analysis. Wear rates are found to be 12.651 and 26.247 mg per million cycle with marginal differences of 0.1 and 0.6 for LHHA-30 and ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups against cobalt–chromium (Co–Cr) alloy femoral head, respectively. Morphological studies carried out by scanning electron microscope revealed that LHHA-30 scored less compared to UHMWPE surface.
- 1 September 2021
- Published by Emerald Publishing in Emerging Materials Research
- Vol. 10 (3) , 329-340
Tribological performances of a novel biopolymeric material HD-HA for hip joint implants
For most modern hip joint implants, metal-on-plastic pairs are preferred over metal-on-metal ones, where cobalt (Co)–chromium (Cr) alloy and ultrahigh-molecular-weight polyethylene (UHMWPE) are commonly used as the femoral head and socket, respectively. In such implants, the durability of the UHMWPE component is not up to the mark due to severe wear. This study presents better tribological performance of a novel biopolymeric material coded as HD-HA prepared from high-density polyethylene (HDPE) and hydroxyapatite. In the first part, wear tests showed specific wear rates of 4.85 × 10−6and 5.27 × 10−6(mm3/N)/m for HDPE and UHMWPE, respectively, whereas the specific wear rate was 3.19 × 10−6(mm3/N)/m for HD-HA. Comparison revealed that HD-HA had a 60–65% lower wear rate than the others. Similarly, in the second part, the friction coefficient is found to be 0.23 and 0.11 for UHMWPE and HDPE, respectively, and 0.06 for HD-HA, which shows a 20–50% decrease in frictional values. Atomic force microscopy images revealed that the rough peaks were 296, 486 and 1100 nm for HD-HA, HDPE and UHMWPE, respectively, whereas the scanning electron microscopy images showed fewer loose particles around the worn HD-HA surface. This shows that HD-HA has a smoother surface, and based on the overall tribological performance, it should be preferred for the acetabular component of hip joint implants.
- 1 September 2021
- Published by Emerald Publishing in Emerging Materials Research
- Vol. 10 (3) , 329-340
Tribological performances of a novel biopolymeric material HD-HA for hip joint implants
For most modern hip joint implants, metal-on-plastic pairs are preferred over metal-on-metal ones, where cobalt (Co)–chromium (Cr) alloy and ultrahigh-molecular-weight polyethylene (UHMWPE) are commonly used as the femoral head and socket, respectively. In such implants, the durability of the UHMWPE component is not up to the mark due to severe wear. This study presents better tribological performance of a novel biopolymeric material coded as HD-HA prepared from high-density polyethylene (HDPE) and hydroxyapatite. In the first part, wear tests showed specific wear rates of 4.85 × 10−6and 5.27 × 10−6(mm3/N)/m for HDPE and UHMWPE, respectively, whereas the specific wear rate was 3.19 × 10−6(mm3/N)/m for HD-HA. Comparison revealed that HD-HA had a 60–65% lower wear rate than the others. Similarly, in the second part, the friction coefficient is found to be 0.23 and 0.11 for UHMWPE and HDPE, respectively, and 0.06 for HD-HA, which shows a 20–50% decrease in frictional values. Atomic force microscopy images revealed that the rough peaks were 296, 486 and 1100 nm for HD-HA, HDPE and UHMWPE, respectively, whereas the scanning electron microscopy images showed fewer loose particles around the worn HD-HA surface. This shows that HD-HA has a smoother surface, and based on the overall tribological performance, it should be preferred for the acetabular component of hip joint implants.
- 1 January 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 47, 1167-1172
Fabrication and selection of suitable biomaterials for acetabular liner of hip implants by using TOPSIS method
- 1 January 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 47, 1167-1172
Fabrication and selection of suitable biomaterials for acetabular liner of hip implants by using TOPSIS method
- 1 June 2019
- Published by Springer Nature
- p. 901-917
Decision-Making for Selection of Most Suitable Materials for Biomedical Applications
- 1 June 2019
- Published by Springer Nature
- p. 901-917
Decision-Making for Selection of Most Suitable Materials for Biomedical Applications
- 24 April 2019
- Published by Springer Nature
- p. 199-206
Study the Wear Behaviour of Al5083-7% B4C Composite Fabricated by Stir Casting Technique
- 24 April 2019
- Published by Springer Nature
- p. 199-206
Study the Wear Behaviour of Al5083-7% B4C Composite Fabricated by Stir Casting Technique
- 31 March 2019
- Published by International Information and Engineering Technology Association in Advances in Modelling and Analysis C
- Vol. 74 (1) , 27-32
Stress Analysis of Hip and Knee Prostheses Using a Novel Biomaterial PTFE Glass Composite
- 31 March 2019
- Published by International Information and Engineering Technology Association in Advances in Modelling and Analysis C
- Vol. 74 (1) , 27-32
Stress Analysis of Hip and Knee Prostheses Using a Novel Biomaterial PTFE Glass Composite
- Open Access
- 1 June 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 377 (1) , 012177
Development of Biomaterial for Total Hip Joint Replacement
- 1 June 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 377 (1) , 012177
Open AccessDevelopment of Biomaterial for Total Hip Joint Replacement