C. Tercero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
C. Tercero has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
F. Arai
Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan
2 shared publicationsI. Takahashi
Department of Neurosurgery, Anjo Kosei Hospital, Japan
2 shared publicationsM. Negoro
Department of Neurosurgery School of Medicine, Fujita Health University, Japan
2 shared publicationsS. Ikeda
Department of Micro‐Nano Systems Engineering, Nagoya University, Nagoya, Japan
2 shared publicationsT. Fukuda
Department of Micro‐Nano Systems Engineering, Nagoya University, Nagoya, Japan
2 shared publicationsI Takahashi
Department of Neurosurgery, Anjo Kosei Hospital, Anjo, Japan
1 shared publication
Latest Publications
- 18 November 2010
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 7 (1) , 33-41
Photoelastic stress analysis in blood vessel phantoms: three‐dimensional visualization and saccular aneurysm with bleb
Background: The photoelastic effect is used for stress measurement during endovascular surgery simulation for quantitative evaluation of catheter trajectory in in vitro environments. By extending the capabilities of this sensing technology, its potential for intravascular tools evaluation will increase.Methods: In this research the error introduced by stress direction on magnitude measurements was studied, then stress measurements were made in the phantom modelling of a saccular aneurysm with bleb. To visualize three‐dimensionally the stress field changes produced by a guide wire in a phantom wall, a scanner and an algorithm relying on maximum likelihood‐expectation maximization are proposed. Three‐dimensional fields at different pressure level were compared with the stress field surrounding the guide wire.Results: The maximum error in stress magnitude measurements due to stress direction was 2.52%. Stress local maximum was detected in the bleb phantom before rupture. Three‐dimensional visualization was obtained in vasculature phantom with average errors of 10.73%, 4.55%, 3.18% for inner pressures of 80, 120, 160 mmHg, respectively. Stress measurement in the neighbourhood of the guide wire is equivalent to applying an inner pressure of 120 mmHg.Conclusions: For the presented polariscope, the weak influence of stress direction in magnitude measurements was confirmed. In vasculature phantoms, the three‐dimensional visualization of stress eliminated birefringence visualization distortion and enabled more comprehensive comparison of stress produced by intravascular tools with stress produced by normal blood pressure. Copyright © 2010 John Wiley & Sons, Ltd.
- 18 November 2010
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 7 (1) , 33-41
Photoelastic stress analysis in blood vessel phantoms: three‐dimensional visualization and saccular aneurysm with bleb
Background: The photoelastic effect is used for stress measurement during endovascular surgery simulation for quantitative evaluation of catheter trajectory in in vitro environments. By extending the capabilities of this sensing technology, its potential for intravascular tools evaluation will increase.Methods: In this research the error introduced by stress direction on magnitude measurements was studied, then stress measurements were made in the phantom modelling of a saccular aneurysm with bleb. To visualize three‐dimensionally the stress field changes produced by a guide wire in a phantom wall, a scanner and an algorithm relying on maximum likelihood‐expectation maximization are proposed. Three‐dimensional fields at different pressure level were compared with the stress field surrounding the guide wire.Results: The maximum error in stress magnitude measurements due to stress direction was 2.52%. Stress local maximum was detected in the bleb phantom before rupture. Three‐dimensional visualization was obtained in vasculature phantom with average errors of 10.73%, 4.55%, 3.18% for inner pressures of 80, 120, 160 mmHg, respectively. Stress measurement in the neighbourhood of the guide wire is equivalent to applying an inner pressure of 120 mmHg.Conclusions: For the presented polariscope, the weak influence of stress direction in magnitude measurements was confirmed. In vasculature phantoms, the three‐dimensional visualization of stress eliminated birefringence visualization distortion and enabled more comprehensive comparison of stress produced by intravascular tools with stress produced by normal blood pressure. Copyright © 2010 John Wiley & Sons, Ltd.
- 1 December 2007
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 3 (4) , 349-354
Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular model
- 1 December 2007
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 3 (4) , 349-354
Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular model
- 22 December 2006
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 3 (1) , 52-58
Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery
Background: In order to reduce fluoroscope usage in endovascular surgery, there is a need to develop autonomous catheter insertion systems.Methods: We propose a system for tracking the position and speed of a catheter using a magnetic motion capture sensor to provide feedback to a catheter‐driving mechanism, to perform autonomous catheter insertion in major vasculature. Catheter insertion speed control and path reconstruction experiments were performed with the system inside a silicone model of major vasculature to simulate surgery.Results: The system controlled the catheter for speeds of 6.14 mm/s and reproduced a two‐dimensional path inside the silicone blood vessel phantom with less than 7 mm of error.Conclusions: We found that error in speed control rises as a result of friction between the catheter and the model wall. Path reconstruction error depends on the model's cross‐sectional diameter, the properties of the catheter insertion mechanism, the magnetic sensor and the system guidance technique. Copyright © 2006 John Wiley & Sons, Ltd.
- 22 December 2006
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 3 (1) , 52-58
Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery
Background: In order to reduce fluoroscope usage in endovascular surgery, there is a need to develop autonomous catheter insertion systems.Methods: We propose a system for tracking the position and speed of a catheter using a magnetic motion capture sensor to provide feedback to a catheter‐driving mechanism, to perform autonomous catheter insertion in major vasculature. Catheter insertion speed control and path reconstruction experiments were performed with the system inside a silicone model of major vasculature to simulate surgery.Results: The system controlled the catheter for speeds of 6.14 mm/s and reproduced a two‐dimensional path inside the silicone blood vessel phantom with less than 7 mm of error.Conclusions: We found that error in speed control rises as a result of friction between the catheter and the model wall. Path reconstruction error depends on the model's cross‐sectional diameter, the properties of the catheter insertion mechanism, the magnetic sensor and the system guidance technique. Copyright © 2006 John Wiley & Sons, Ltd.