Photoelastic stress analysis in blood vessel phantoms: three‐dimensional visualization and saccular aneurysm with bleb
Authors:
- 18 November 2010
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 7 (1) , 33-41
Abstract
Background: The photoelastic effect is used for stress measurement during endovascular surgery simulation for quantitative evaluation of catheter trajectory in in vitro environments. By extending the capabilities of this sensing technology, its potential for intravascular tools evaluation will increase.Methods: In this research the error introduced by stress direction on magnitude measurements was studied, then stress measurements were made in the phantom modelling of a saccular aneurysm with bleb. To visualize three‐dimensionally the stress field changes produced by a guide wire in a phantom wall, a scanner and an algorithm relying on maximum likelihood‐expectation maximization are proposed. Three‐dimensional fields at different pressure level were compared with the stress field surrounding the guide wire.Results: The maximum error in stress magnitude measurements due to stress direction was 2.52%. Stress local maximum was detected in the bleb phantom before rupture. Three‐dimensional visualization was obtained in vasculature phantom with average errors of 10.73%, 4.55%, 3.18% for inner pressures of 80, 120, 160 mmHg, respectively. Stress measurement in the neighbourhood of the guide wire is equivalent to applying an inner pressure of 120 mmHg.Conclusions: For the presented polariscope, the weak influence of stress direction in magnitude measurements was confirmed. In vasculature phantoms, the three‐dimensional visualization of stress eliminated birefringence visualization distortion and enabled more comprehensive comparison of stress produced by intravascular tools with stress produced by normal blood pressure. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
Funding Information
- Global Centers of Excellence program of Nagoya University
- Grants-in-Aid for Scientific Research of the Japan Society of Promotion of Science
This publication has 9 references indexed in Scilit:
- Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback ControlIEEE/ASME Transactions on Mechatronics, 2010
- Human Blood Pressure Simulation for Stress Analysis in Model of Vasculature Using Photoelastic EffectInternational Journal of Automation Technology, 2009
- Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular modelThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- An In Vitro Patient-Specific Biological Model of the Cerebral Artery Reproduced with a Membranous Configuration for Simulating Endovascular InterventionJournal of Robotics and Mechatronics, 2005
- Polarized Light, Revised and Expanded2003
- High-Normal Blood Pressure — More “High” Than “Normal”New England Journal of Medicine, 2001
- Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating techniqueIEEE Transactions on Biomedical Engineering, 2000
- A photoelastic study of ligament strainIEEE Transactions on Rehabilitation Engineering, 1998